95 research outputs found

    Durability of treatment effects of the Sleep Position Trainer versus oral appliance therapy in positional OSA: 12-month follow-up of a randomized controlled trial

    Get PDF
    The Sleep Position Trainer (SPT) is a new option for treating patients with positional obstructive sleep apnea (POSA). This study investigated long-term efficacy, adherence, and quality of life during use of the SPT device compared with oral appliance therapy (OAT) in patients with POSA. This prospective, multicenter trial randomized patients with mild to moderate POSA (apnea-hypopnea index [AHI] 5-30/h) to SPT or OAT. Polysomnography was performed at baseline and after 3 and 12 months' follow-up. The primary endpoint was OSA severity; adherence, quality of life, and adverse events were also assessed. Ninety-nine patients were randomized and 58 completed the study (29 in each group). Median AHI in the SPT group decreased from 13.2/h at baseline to 7.1/h after 12 months (P < 0.001); corresponding values in the OAT group were 13.4/h and 5.0/h (P < 0.001), with no significant between-group difference (P = 1.000). Improvements throughout the study were maintained at 12 months. Long-term median adherence was also similar in the two treatment groups; the proportion of patients who used their device for ≄ 4 h for 5 days in a week was 100% in the SPT group and 97.0% in the OAT group (P = 0.598). The efficacy of SPT therapy was maintained over 12 months and was comparable to that of OAT in patients with mild to moderate POSA. Adherence was relatively high, and similar in the two groups. www.clinicaltrials.gov (NCT02045576

    Obesity and craniofacial variables in subjects with obstructive sleep apnea syndrome: comparisons of cephalometric values

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this paper was to determine the most common craniofacial changes in patients suffering Obstructive Sleep Apnea Syndrome (OSAS) with regards to the degree of obesity. Accordingly, cephalometric data reported in the literature was searched and analyzed.</p> <p>Methods</p> <p>After a careful analysis of the literature from 1990 to 2006, 5 papers with similar procedural criteria were selected. Inclusion criteria were: recruitment of Caucasian patients with an apnea-hypopnea index (AHI) >10 as grouped in non-obese (Body Mass Index – [BMI] < 30) <it>vs</it>. obese (BMI ≄ 30).</p> <p>Results</p> <p>A low position of the hyoid bone was present in both groups. In non-obese patients, an increased value of the ANB angle and a reduced dimension of the cranial base (S-N) were found to be the most common finding, whereas major skeletal divergence (ANS-PNS ^Go-Me) was evident among obese patients. No strict association was found between OSAS and length of the soft palate.</p> <p>Conclusion</p> <p>In both non-obese and obese OSAS patients, skeletal changes were often evident; with special emphasis of intermaxillary divergence in obese patients. Unexpectedly, in obese OSAS patients, alterations of oropharyngeal soft tissue were not always present and did not prevail.</p

    Randomised short-term trial of high-span versus low-span APAP for treating sleep apnoea

    Get PDF
    PURPOSE: Auto-titrating continuous positive airway pressure (APAP) devices were developed to improve treatment efficacy and compliance in patients with obstructive sleep apnoea syndrome (OSAS). Since there are insufficient data on the optimal pressure range setting, we aimed to compare the adherence, efficacy and tolerability of treatment with high-span versus low-span APAP. METHODS: Seventy-six newly diagnosed OSAS patients fulfilling the treatment criteria were randomised to receive high-span (HS, range 4-15cmH2O, n?=?38) or low-span (LS, range 8-12cmH2O, n?=?38) APAP. Patients were assessed at 1 and 3 months. RESULTS: Median Epworth sleepiness scale (ESS) was 13 (IQR, 6-16) and median apnoea-hypopnoea index (AHI) was 35.9 (IQR, 27.6-56.3). There were no significant differences in baseline demographic and clinical characteristics between groups. Overall, no significant differences were found at the first month assessment. After 3 months of therapy, we found again no differences in residual AHI or ESS. However, the group HS proved less adherent than group LS, respectively, with median 87 % (IQR, 60.5-97.5) versus 94 % (IQR, 80.0-98.3) of the nights using =4 h (P?=?0.014) and mean (±SD) usage 5.7?±?1.6 versus 6.4?±?1.2 h/night (P?=?0.049). The group HS reported more frequently nasal congestion, excessive oronasal dryness and nocturnal awakenings of at least moderate intensity, the latter with statistical significance (P?=?0.005). CONCLUSIONS: Both pressure ranges appear to be equally effective to correct AHI and to improve symptoms. Though, patients with high-span APAP were less compliant to treatment, raising issues about the tolerability of wide pressure range settings of these devices.T Pinto has received financial support from Linde and Vitalaire (Healthcare Providers) for attending symposia and honoraria for speaking at symposia from Philips. After the conclusion of the study, JC Winck has started working in a global position for Linde. The remaining authors declare that they have no conflict of interest

    The Impact of Long-Term Exposure to Space Environment on Adult Mammalian Organisms: A Study on Mouse Thyroid and Testis

    Get PDF
    Hormonal changes in humans during spaceflight have been demonstrated but the underlying mechanisms are still unknown. To clarify this point thyroid and testis/epididymis, both regulated by anterior pituitary gland, have been analyzed on long-term space-exposed male C57BL/10 mice, either wild type or pleiotrophin transgenic, overexpressing osteoblast stimulating factor-1. Glands were submitted to morphological and functional analysis

    A study of alterations in DNA epigenetic modifications (5mC and 5hmC) and gene expression influenced by simulated microgravity in human lymphoblastoid cells

    Get PDF
    Cells alter their gene expression in response to exposure to various environmental changes. Epigenetic mechanisms such as DNA methylation are believed to regulate the alterations in gene expression patterns. In vitro and in vivo studies have documented changes in cellular proliferation, cytoskeletal remodeling, signal transduction, bone mineralization and immune deficiency under the influence of microgravity conditions experienced in space. However microgravity induced changes in the epigenome have not been well characterized. In this study we have used Next-generation Sequencing (NGS) to profile ground-based “simulated” microgravity induced changes on DNA methylation (5-methylcytosine or 5mC), hydroxymethylation (5-hydroxymethylcytosine or 5hmC), and simultaneous gene expression in cultured human lymphoblastoid cells. Our results indicate that simulated microgravity induced alterations in the methylome (~60% of the differentially methylated regions or DMRs are hypomethylated and ~92% of the differentially hydroxymethylated regions or DHMRs are hyperhydroxymethylated). Simulated microgravity also induced differential expression in 370 transcripts that were associated with crucial biological processes such as oxidative stress response, carbohydrate metabolism and regulation of transcription. While we were not able to obtain any global trend correlating the changes of methylation/ hydroxylation with gene expression, we have been able to profile the simulated microgravity induced changes of 5mC over some of the differentially expressed genes that includes five genes undergoing differential methylation over their promoters and twenty five genes undergoing differential methylation over their gene-bodies. To the best of our knowledge, this is the first NGS-based study to profile epigenomic patterns induced by short time exposure of simulated microgravity and we believe that our findings can be a valuable resource for future explorations

    Application of Surface wave methods for seismic site characterization

    Get PDF
    Surface-wave dispersion analysis is widely used in geophysics to infer a shear wave velocity model of the subsoil for a wide variety of applications. A shear-wave velocity model is obtained from the solution of an inverse problem based on the surface wave dispersive propagation in vertically heterogeneous media. The analysis can be based either on active source measurements or on seismic noise recordings. This paper discusses the most typical choices for collection and interpretation of experimental data, providing a state of the art on the different steps involved in surface wave surveys. In particular, the different strategies for processing experimental data and to solve the inverse problem are presented, along with their advantages and disadvantages. Also, some issues related to the characteristics of passive surface wave data and their use in H/V spectral ratio technique are discussed as additional information to be used independently or in conjunction with dispersion analysis. Finally, some recommendations for the use of surface wave methods are presented, while also outlining future trends in the research of this topic

    Implanted upper-airway stimulator improves sleep apnoea

    Full text link

    Sternal Involvement in Anterior Mediastinal Seminoma - A Rare Presentation

    Full text link
    • 

    corecore