5 research outputs found

    Hardware-in-the-loop test for real-time economic control of a DC microgrid

    No full text
    Microgrids (MGs) utilising both renewables and energy storage to optimise onsite energy consumption rather than importing power form the utility grid, require a tertiary-level energy management system (EMS). The EMS must monitor and control the energy exchange within the nodes of MG to maximise any solar energy generation and benefit from installed storage. This paper considers a single-family house as the MG that has DC distribution circuit model. The look-ahead EMS is formulated as a linear programming problem, which has been tested in both offline simulation and hardware-in-the-loop (HIL) simulation environment. The simulation results indicate that the proposed look-ahead EMS can effectively reduce the DC MG operation cost without any operational constraint violation. In addition, the proposed look ahead energy optimisation approach has the potential to be used in a large-scale system such as a community MG with multiple buildings.Peer reviewe

    Extra-Fast DC Distribution System Protection for Future Energy Systems

    No full text

    Impact of DC Voltage Enhancement on Partial Discharges in Medium Voltage Cables—An Empirical Study with Defects at Semicon-Dielectric Interface

    No full text
    A scientific consensus is emerging on the benefits of direct current (DC) distribution in medium voltage (MV) power systems of ships and cities. At least 50% space savings and increased power transfer capacity are estimated with enhanced voltage DC operation of electric cables. The goal of this research is to contribute to developing the empirical knowledge on the insulation performance in order to validate the feasibility of such anticipated gains of DC versus alternating current (AC), and to determine the comparative impact of different operational conditions from a component engineering point of view. The partial discharge (PD) activity in cables is measured under AC and DC conditions as an indicator of insulation performance. Specifically, PDs in defects at the semicon-insulation interface are studied in terms of inception voltage, repetition rate and discharge magnitude. Empirical understanding is drawn for operating voltage and frequency dependence of the discharge behavior in such voids in the range of 10 to 20 kV and 0 to 0.1 Hz, respectively. The change in PD activity with void evolution post temperature-induced ageing process is explored

    Impact of DC Voltage Enhancement on Partial Discharges in Medium Voltage Cables - An Empirical Study with Defects at Semicon-Dielectric Interface

    Full text link
    La Pensée de midi est une revue thématique biannuelle qui a cessé de paraître en 2010 (le n°31 est son dernier numéro). Les numéros thématiques de cette revue, extrêmement variés, étaient tous reliés à la Méditerranée, portant sur des lieux (Palerme, Athènes, Alger, Tanger, l'Egypte…) ou des débats artistiques, littéraires ou politiques. A partir de 2009 la revue a été hébergée sur le portail Cairn où elle est toujours accessible en libre accès. Les sommaires de tous les numéros organisés par..

    Impact of DC Voltage Enhancement on Partial Discharges in Medium Voltage Cables: An Empirical Study with Defects at Semicon-Dielectric Interface

    No full text
    A scientific consensus is emerging on the benefits of direct current (DC) distribution in medium voltage (MV) power systems of ships and cities. At least 50% space savings and increased power transfer capacity are estimated with enhanced voltage DC operation of electric cables. The goal of this research is to contribute to developing the empirical knowledge on the insulation performance in order to validate the feasibility of such anticipated gains of DC versus alternating current (AC), and to determine the comparative impact of different operational conditions from a component engineering point of view. The partial discharge (PD) activity in cables is measured under AC and DC conditions as an indicator of insulation performance. Specifically, PDs in defects at the semicon-insulation interface are studied in terms of inception voltage, repetition rate and discharge magnitude. Empirical understanding is drawn for operating voltage and frequency dependence of the discharge behavior in such voids in the range of 10 to 20 kV and 0 to 0.1 Hz, respectively. The change in PD activity with void evolution post temperature-induced ageing process is exploredDC systems, Energy conversion & Storag
    corecore