727 research outputs found

    A Modified Approach to Single-Spin Detection Using Magnetic Resonance Force Microscopy

    Full text link
    The magnetic moment of a single spin interacting with a cantilever in magnetic resonance force microscopy (MRFM) experiences quantum jumps in orientation rather than smooth oscillations. These jumps cannot be detected by a conventional MRFM based on observation of driven resonant oscillations of a cantilever. In this paper, we propose a method which will allow detection of the magnetic signal from a single spin using a modification of a conventional MRFM. We estimate the opportunity to detect the magnetic signal from a single proton.Comment: 4 pages LaTex, 4 figures in GIF forma

    Velocity-selective direct frequency-comb spectroscopy of atomic vapors

    Get PDF
    We present an experimental and theoretical investigation of two-photon direct frequency-comb spectroscopy performed through velocity-selective excitation. In particular, we explore the effect of repetition rate on the 5S1/25D3/2,5/2\textrm{5S}_{1/2}\rightarrow \textrm{5D}_{3/2, 5/2} two-photon transitions excited in a rubidium atomic vapor cell. The transitions occur via step-wise excitation through the 5P1/2,3/2\textrm{5P}_{1/2, 3/2} states by use of the direct output of an optical frequency comb. Experiments were performed with two different frequency combs, one with a repetition rate of 925\approx 925 MHz and one with a repetition rate of 250\approx 250 MHz. The experimental spectra are compared to each other and to a theoretical model.Comment: 10 pages, 7 figure

    Prospects for precision measurements of atomic helium using direct frequency comb spectroscopy

    Full text link
    We analyze several possibilities for precisely measuring electronic transitions in atomic helium by the direct use of phase-stabilized femtosecond frequency combs. Because the comb is self-calibrating and can be shifted into the ultraviolet spectral region via harmonic generation, it offers the prospect of greatly improved accuracy for UV and far-UV transitions. To take advantage of this accuracy an ultracold helium sample is needed. For measurements of the triplet spectrum a magneto-optical trap (MOT) can be used to cool and trap metastable 2^3S state atoms. We analyze schemes for measuring the two-photon 23S43S2^3S \to 4^3S interval, and for resonant two-photon excitation to high Rydberg states, 23S33Pn3S,D2^3S \to 3^3P \to n^3S,D. We also analyze experiments on the singlet-state spectrum. To accomplish this we propose schemes for producing and trapping ultracold helium in the 1^1S or 2^1S state via intercombination transitions. A particularly intriguing scenario is the possibility of measuring the 11S21S1^1S \to 2^1S transition with extremely high accuracy by use of two-photon excitation in a magic wavelength trap that operates identically for both states. We predict a ``triple magic wavelength'' at 412 nm that could facilitate numerous experiments on trapped helium atoms, because here the polarizabilities of the 1^1S, 2^1S and 2^3S states are all similar, small, and positive.Comment: Shortened slightly and reformatted for Eur. Phys. J.

    Coherence as ultrashort pulse train generator

    Full text link
    Intense, well-controlled regular light pulse trains start to play a crucial role in many fields of physics. We theoretically demonstrate a very simple and robust technique for generating such periodic ultrashort pulses from a continuous probe wave which propagates in a dispersive thermal gas media

    An all silicon quantum computer

    Get PDF
    A solid-state implementation of a quantum computer composed entirely of silicon is proposed. Qubits are Si-29 nuclear spins arranged as chains in a Si-28 (spin-0) matrix with Larmor frequencies separated by a large magnetic field gradient. No impurity dopants or electrical contacts are needed. Initialization is accomplished by optical pumping, algorithmic cooling, and pseudo-pure state techniques. Magnetic resonance force microscopy is used for readout. This proposal takes advantage of many of the successful aspects of solution NMR quantum computation, including ensemble measurement, RF control, and long decoherence times, but it allows for more qubits and improved initialization.Comment: ReVTeX 4, 5 pages, 2 figure

    Quantum Measurement of a Single Spin using Magnetic Resonance Force Microscopy

    Get PDF
    Single-spin detection is one of the important challenges facing the development of several new technologies, e.g. single-spin transistors and solid-state quantum computation. Magnetic resonance force microscopy with a cyclic adiabatic inversion, which utilizes a cantilever oscillations driven by a single spin, is a promising technique to solve this problem. We have studied the quantum dynamics of a single spin interacting with a quasiclassical cantilever. It was found that in a similar fashion to the Stern-Gerlach interferometer the quantum dynamics generates a quantum superposition of two quasiclassical trajectories of the cantilever which are related to the two spin projections on the direction of the effective magnetic field in the rotating reference frame. Our results show that quantum jumps will not prevent a single-spin measurement if the coupling between the cantilever vibrations and the spin is small in comparison with the amplitude of the radio-frequency external field.Comment: 16 pages RevTeX including 4 figure

    Multicenter flow cytometry proficiency testing of canine blood and lymph node samples

    Get PDF
    Background: Flow cytometry (FC) is used increasingly in veterinary medicine for further characterization of hematolymphoid cells. Guidelines for optimizing assay performance and interpretation of results are limited, and concordance of results across laboratories is unknown. Objectives: This study aimed to determine inter-investigator agreement on the interpretation of FC results from split samples analyzed in different laboratories using various protocols, cytometers, and software; and on the interpretation of archived FC standard (FCS) data files contributed by the different investigators. Methods: This was a multicenter observational cross-sectional study. Anticoagulated blood or lymph node aspirate samples from nine client-owned dogs were aliquoted and shipped to participating laboratories. Samples were analyzed with individual laboratory-developed protocols. In addition, FCS files from a set of separate samples from 11 client-owned dogs were analyzed by participating investigators. A person not associated with the study tabulated the results and interpretations. Agreement of interpretations was assessed with Fleiss\u2019 kappa statistic. Results: Prolonged transit times affected sample quality for some laboratories. Overall agreement among investigators regarding the FC sample interpretation was strong (\u3ba = 0.86 \ub1 0.19, P <.001), and for specific categories, ranged from moderate to perfect. Agreement of the lymphoproliferation or other leukocyte sample category from the analysis of the FCS files was weak (\u3ba = 0.58 \ub1 0.05, P <.001). Conclusions: Lymphoproliferations were readily identified by FC, but identification of the categories of hematolymphoid neoplasia in fresh samples or archived files was variable. There is a need for a more standardized approach to maximize the enormous potential of FC in veterinary medicine

    An off-board quantum point contact as a sensitive detector of cantilever motion

    Full text link
    Recent advances in the fabrication of microelectromechanical systems (MEMS) and their evolution into nanoelectromechanical systems (NEMS) have allowed researchers to measure extremely small forces, masses, and displacements. In particular, researchers have developed position transducers with resolution approaching the uncertainty limit set by quantum mechanics. The achievement of such resolution has implications not only for the detection of quantum behavior in mechanical systems, but also for a variety of other precision experiments including the bounding of deviations from Newtonian gravity at short distances and the measurement of single spins. Here we demonstrate the use of a quantum point contact (QPC) as a sensitive displacement detector capable of sensing the low-temperature thermal motion of a nearby micromechanical cantilever. Advantages of this approach include versatility due to its off-board design, compatibility with nanoscale oscillators, and, with further development, the potential to achieve quantum limited displacement detection.Comment: 5 pages, 5 figure

    Ultrasensitive force and displacement detection using trapped ions

    Full text link
    The ability to detect extremely small forces is vital for a variety of disciplines including precision spin-resonance imaging, microscopy, and tests of fundamental physical phenomena. Current force-detection sensitivity limits have surpassed 1 aN/HzaN/\sqrt{Hz} (atto =1018=10^{-18}) through coupling of micro or nanofabricated mechanical resonators to a variety of physical systems including single-electron transistors, superconducting microwave cavities, and individual spins. These experiments have allowed for probing studies of a variety of phenomena, but sensitivity requirements are ever-increasing as new regimes of physical interactions are considered. Here we show that trapped atomic ions are exquisitely sensitive force detectors, with a measured sensitivity more than three orders of magnitude better than existing reports. We demonstrate detection of forces as small as 174 yNyN (yocto =1024=10^{-24}), with a sensitivity 390±150\pm150 yN/HzyN/\sqrt{Hz} using crystals of n=60n=60 9^{9}Be+^{+} ions in a Penning trap. Our technique is based on the excitation of normal motional modes in an ion trap by externally applied electric fields, detection via and phase-coherent Doppler velocimetry, which allows for the discrimination of ion motion with amplitudes on the scale of nanometers. These experimental results and extracted force-detection sensitivities in the single-ion limit validate proposals suggesting that trapped atomic ions are capable of detecting of forces with sensitivity approaching 1 yN/HzyN/\sqrt{Hz}. We anticipate that this demonstration will be strongly motivational for the development of a new class of deployable trapped-ion-based sensors, and will permit scientists to access new regimes in materials science.Comment: Expanded introduction and analysis. Methods section added. Subject to press embarg
    corecore