1,001 research outputs found

    Cochrane dementia group turns 21—older and (slightly) wiser

    Get PDF
    This invited editorial describes the achievements of the last 21 years of the Cochrane Dementia and Cognitive Improvement Group (DR Quinn is the coordinating editor of the group)

    Are methodological quality and completeness of reporting associated with citation-based measures of publication impact? A secondary analysis of a systematic review of dementia biomarker studies

    Get PDF
    Objective: To determine whether methodological and reporting quality are associated with surrogate measures of publication impact in the field of dementia biomarker studies. Methods: We assessed dementia biomarker studies included in a previous systematic review in terms of methodological and reporting quality using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and Standards for Reporting of Diagnostic Accuracy (STARD), respectively. We extracted additional study and journal-related data from each publication to account for factors shown to be associated with impact in previous research. We explored associations between potential determinants and measures of publication impact in univariable and stepwise multivariable linear regression analyses. Outcome measures: We aimed to collect data on four measures of publication impact: two traditional measures—average number of citations per year and 5-year impact factor of the publishing journal and two alternative measures—the Altmetric Attention Score and counts of electronic downloads. Results: The systematic review included 142 studies. Due to limited data, Altmetric Attention Scores and electronic downloads were excluded from the analysis, leaving traditional metrics as the only analysed outcome measures. We found no relationship between QUADAS and traditional metrics. Citation rates were independently associated with 5-year journal impact factor (β=0.42; p<0.001), journal subject area (β=0.39; p<0.001), number of years since publication (β=-0.29; p<0.001) and STARD (β=0.13; p<0.05). Independent determinants of 5-year journal impact factor were citation rates (β=0.45; p<0.001), statement on conflict of interest (β=0.22; p<0.01) and baseline sample size (β=0.15; p<0.05). Conclusions: Citation rates and 5-year journal impact factor appear to measure different dimensions of impact. Citation rates were weakly associated with completeness of reporting, while neither traditional metric was related to methodological rigour. Our results suggest that high publication usage and journal outlet is not a guarantee of quality and readers should critically appraise all papers regardless of presumed impact

    Endogenous glucagon-like peptide 1 controls endocrine pancreatic secretion and antro-pyloro-duodenal motility in humans

    Get PDF
    Background: Exogenous use of the intestinal hormone glucagon-like peptide 1 (GLP-1) lowers glycaemia by stimulation of insulin, inhibition of glucagon, and delay of gastric emptying.Aims: To assess the effects of endogenous GLP-1 on endocrine pancreatic secretion and antro-pyloro-duodenal motility by utilising the GLP-1 receptor antagonist exendin(9-39)amide (ex(9-39)NH2).Methods: Nine healthy volunteers underwent four experiments each. In two experiments with and without intravenous infusion of ex(9-39)NH2 300 pmol/kg/min, a fasting period was followed by intraduodenal glucose perfusion at 1 and 2.5 kcal/min, with the higher dose stimulating GLP-1 release. Antro-pyloro-duodenal motility was measured by perfusion manometry. To calculate the incretin effect (that is, the proportion of plasma insulin stimulated by intestinal hormones) the glycaemia observed during the luminal glucose experiments was mimicked using intravenous glucose in two further experiments.Results: Ex(9-39)NH2 significantly increased glycaemia during fasting and duodenal glucose. It diminished plasma insulin during duodenal glucose and significantly reduced the incretin effect by approximately 50%. Ex(9-39)NH2 raised plasma glucagon during fasting and abolished the decrease in glucagon at the high duodenal glucose load. Ex(9-39)NH2 markedly stimulated antroduodenal contractility. At low duodenal glucose it reduced the stimulation of tonic and phasic pyloric motility. At the high duodenal glucose load it abolished pyloric stimulation.Conclusions: Endogenous GLP-1 stimulates postprandial insulin release. The pancreatic \textgreeka cell is under the tonic inhibitory control of GLP-1 thereby suppressing postprandial glucagon. GLP-1 tonically inhibits antroduodenal motility and mediates the postprandial inhibition of antral and stimulation of pyloric motility. We therefore suggest GLP-1 as a true incretin hormone and enterogastrone in humans

    Herbal extracts modulate the amplitude and frequency of slow waves in circular smooth muscle of mouse small intestine

    Get PDF
    Background: Herbal preparations like STW 5 (Iberogast(R)) are widely used drugs in the treatment of dyspepsia and motility-related disorders of the gastrointestinal tract. STW 5 is a phytotherapeutic agent consisting of a fixed mixture of 9 individual plant extracts. The electrophysiological mechanisms of action of STW 5 remain obscure. Aim: The aim of the present study was to investigate whether herbal extracts influence electrophysiological parameters of the small intestine. For this purpose, the resting membrane potential (RMP) and the slow wave rhythmicity of smooth muscle cells of mouse small intestine were observed. Methods: Intracellular recordings of smooth muscle cells of the circular muscle layer of mouse small intestine were performed using standard microelectrode techniques. After dissection of the mucosa, the small intestine was placed in an organ bath and a microelectrode was applied on a circular smooth muscle cell. The RMP and the amplitude of slow waves were measured in millivolts. Results: The RMP of smooth muscle cells was - 59 +/- 1.3 mV. This RMP was significantly depolarized by STW 5 ( 9.6 +/- 1.6 mV); the depolarizing effects can be mainly attributed to the constituents of matricariae flos, angelicae radix and chelidonii herba. The basal frequency of small intestinal slow waves was 39.5 +/- 1.4 min(-1) and the amplitude was 23.1 +/- 0.9 mV. STW 5 significantly reduced the amplitude and frequency of the slow waves ( 11.7 +/- 0.8 mV; 33.5 +/- 3.4 min(-1)). This effect on slow waves represents the sum of the effects of the 9 phytoextracts. Whereas angelicae radix and matricariae flos completely blocked slow wave activity, Iberis amara increased the frequency and amplitude, chelidonii herba reduced the frequency and amplitude of the slow waves, mentae piperitae folium reduced the frequency and left amplitude unchanged and liquiritae radix, carvi fructus and melissae folium had no effects. Conclusion: Herbal extracts cause changes in smooth muscle RMP and slow wave rhythmicity, up to reversible abolition, by blockade of large conductance Ca2+ channels and other not yet identified mechanisms. In herbal preparations like STW 5 these effects add up to a total effect and this study indicates that herbal preparations which are widely used in dyspepsia and motility-related disorders have characteristic, reproducible, reversible effects on small intestinal electrophysiology. Copyright (C) 2005 S. Karger AG, Basel

    Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) for the diagnosis of dementia within community dwelling populations

    Get PDF
    <b>Background</b><p></p> Various tools exist for initial assessment of possible dementia with no consensus on the optimal assessment method. Instruments that use collateral sources to assess change in cognitive function over time may have particular utility. The most commonly used informant dementia assessment is the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE).<p></p> A synthesis of the available data regarding IQCODE accuracy will help inform cognitive assessment strategies for clinical practice, research and policy.<p></p> <b>Objectives</b><p></p> Our primary objective was to determine the diagnostic accuracy of the informant based questionnaire IQCODE, for detection of all cause (undifferentiated) dementia in community-dwelling adults with no previous cognitive assessment. We sought to describe the accuracy of IQCODE (the index test) against a clinical diagnosis of dementia (the reference standard).<p></p> Our secondary objective was to describe the effect of heterogeneity on the summary estimates. We were particularly interested in the traditional 26-item scale versus the 16-item short form; and language of administration. We explored the effect of varying the threshold IQCODE score used to define 'test positivity'.<p></p> <b>Search methods</b><p></p> We searched the following sources on 28 January 2013: ALOIS (Cochrane Dementia and Cognitive Improvement Group), MEDLINE (OvidSP), EMBASE (OvidSP), PsycINFO (OvidSP), BIOSIS Previews (ISI Web of Knowledge), Web of Science with Conference Proceedings (ISI Web of Knowledge), LILACS (BIREME). We also searched sources relevant or specific to diagnostic test accuracy: MEDION (Universities of Maastrict and Leuven); DARE (York University); ARIF (Birmingham University). We used sensitive search terms based on MeSH terms and other controlled vocabulary.<p></p> <b>Selection criteria</b><p></p> We selected those studies performed in community settings that used (not necessarily exclusively) the IQCODE to assess for presence of dementia and, where dementia diagnosis was confirmed, with clinical assessment. Our intention with limiting the search to a 'community' setting was to include those studies closest to population level assessment. Within our predefined community inclusion criteria, there were relevant papers that fulfilled our definition of community dwelling but represented a selected population, for example stroke survivors. We included these studies but performed sensitivity analyses to assess the effects of these less representative populations on the summary results.<p></p> <b>Data collection and analysis</b><p></p> We screened all titles generated by the electronic database searches and abstracts of all potentially relevant studies were reviewed. Full papers were assessed for eligibility and data extracted by two independent assessors. For quality assessment (risk of bias and applicability) we used the QUADAS 2 tool. We included test accuracy data on the IQCODE used at predefined diagnostic thresholds. Where data allowed, we performed meta-analyses to calculate summary values of sensitivity and specificity with corresponding 95% confidence intervals (CIs). We pre-specified analyses to describe the effect of IQCODE format (traditional or short form) and language of administration for the IQCODE.<p></p> <b>Main results</b><p></p> From 16,144 citations, 71 papers described IQCODE test accuracy. We included 10 papers (11 independent datasets) representing data from 2644 individuals (n = 379 (14%) with dementia). Using IQCODE cut-offs commonly employed in clinical practice (3.3, 3.4, 3.5, 3.6) the sensitivity and specificity of IQCODE for diagnosis of dementia across the studies were generally above 75%.<p></p> Taking an IQCODE threshold of 3.3 (or closest available) the sensitivity was 0.80 (95% CI 0.75 to 0.85); specificity was 0.84 (95% CI 0.78 to 0.90); positive likelihood ratio was 5.2 (95% CI 3.7 to 7.5) and the negative likelihood ratio was 0.23 (95% CI 0.19 to 0.29).<p></p> Comparative analysis suggested no significant difference in the test accuracy of the 16 and 26-item IQCODE tests and no significant difference in test accuracy by language of administration. There was little difference in sensitivity across our predefined diagnostic cut-points.<p></p> There was substantial heterogeneity in the included studies. Sensitivity analyses removing potentially unrepresentative populations in these studies made little difference to the pooled data estimates. The majority of included papers had potential for bias, particularly around participant selection and sampling. The quality of reporting was suboptimal particularly regarding timing of assessments and descriptors of reproducibility and inter-observer variability.<p></p> <b>Authors' conclusions</b><p></p> Published data suggest that if using the IQCODE for community dwelling older adults, the 16 item IQCODE may be preferable to the traditional scale due to lesser test burden and no obvious difference in accuracy. Although IQCODE test accuracy is in a range that many would consider 'reasonable', in the context of community or population settings the use of the IQCODE alone would result in substantial misdiagnosis and false reassurance. Across the included studies there were issues with heterogeneity, several potential biases and suboptimal reporting quality

    Non-specific abdominal pain and air pollution: a novel association.

    Get PDF
    We studied whether short-term exposure to air pollution was associated with non-specific abdominal pain in epidemiologic and animal studies. Patients visiting the emergency department with non-specific abdominal pain were identified in Edmonton (1992 to 2002, n = 95,173) and Montreal (1997 to 2002, n = 25,852). We calculated the daily concentrations for ozone (O(3)), nitrogen dioxide (NO(2)), sulfur dioxide (SO(2)), carbon monoxide (CO), and particles <10 (PM(10)) or <2.5 (PM(2.5)) µm. A case crossover study design was used to estimate the odds ratio (OR) and 95% confidence interval (CI) associated with an increase in the interquartile range of the air pollutants. We investigated differential effects by age and sex. Mice were gavaged with urban particle extracts. In animal models, colonic motility was tested, and visceral abdominal pain was measured using a writhing test, and behavioral response to oil of mustard and neostigmine. Motility and pain was measured acutely (1.5 hours after gavage) and chronically (7-days and 21-days after gavage). Emergency department visits for non-specific abdominal pain were primarily by women between the ages of 15-24 years. Individuals aged 15 to 24 years were at increased risk of non-specific abdominal pain in Edmonton (same day CO: OR = 1.04, 95% CI = 1.02-1.06; and NO(2): OR = 1.06, 95% CI = 1.03-1.09). The risk of air pollution among 15-24 year olds in Montreal was significantly positive (same day CO: OR = 1.11, 95% CI = 1.05-1.17; NO(2): OR = 1.09, 95% CI = 1.01-1.16; SO(2): OR = 1.17, 95% CI = 1.10-1.25; PM(2.5): OR = 1.09, 95% CI = 1.04-1.15). Abdominal pain was increased by an acute gavage of pollution extract but not to chronic exposure to pollutants. Colonic transit was delayed following chronic but not acute exposure with the pollutants. Epidemiological and animal data suggest that short-term exposure to air pollution may trigger non-specific abdominal pain in young individuals

    Shubnikov de Haas effect in the metallic state of Na0.3_{0.3}CoO2_2

    Full text link
    Shubnikov de Haas oscillations for two well defined frequencies, corresponding respectively to areas of 0.8 and 1.36% of the first Brillouin zone (FBZ), were observed in single crystals of Na0.3_{0.3}CoO2_2. The existence of Na superstructures in Na0.3_{0.3}CoO2_2, coupled with this observation, suggests the possibility that the periods are due to the reconstruction of the large Fermi surface around the Γ\Gamma point. An alternative interpretation in terms of the long sought-after ϵg′\epsilon_g^\prime pockets is also considered but found to be incompatible with existing specific heat data.Comment: 5 pages 4 figure

    Lecture object: an architecture for archiving lectures on the Web

    Get PDF
    A new software architectural model for the archival of slide-based presentations on the Internet is proposed. This architecture is based on the concept of the "lecture object," a persistent format, independent of the lecture production and viewing technology. The work has been undertaken in the context of the Web Lecture Archive Project, a collaboration of the CERN HR Division Training and Development group and the University of Michigan, Ann Arbor. To date some 250 lectures have been archived and are viewable worldwide using standard Web browsers and freely available video player software
    • …
    corecore