17 research outputs found

    Ideopathic sudden sensorineural hearing loss

    Get PDF
    Since the beginning of the 20th century, otologists have reported cases of sudden, unexpected sensorineural hearing loss. Today, in spite of the advancements in medicine, the pathophysiology of Idiopathic Sudden Sensorineural Hearing Loss (ISSHL) has not been elucidated and little can be offered to people struck by the hearing loss. ... Zie: Samenvatting

    The acoustic change complex compared to hearing performance in unilaterally and bilaterally deaf cochlear implant users

    No full text
    Clinical measures evaluating hearing performance in cochlear implant (CI) users depend on attention and linguistic skills, which limits the evaluation of auditory perception in some patients. The acoustic change complex (ACC), a cortical auditory evoked potential to a sound change, might yield useful objective measures to assess hearing performance and could provide insight in cortical auditory processing. The aim of this study is to examine the ACC in response to frequency changes as an objective measure for hearing performance in CI users. DESIGN: Thirteen bilaterally deaf and six single-sided deaf subjects were included, all having used a unilateral CI for at least 1 year. Speech perception was tested with a consonant-vowel-consonant test (+10 dB signal-to-noise ratio) and a digits-in-noise test. Frequency discrimination thresholds were measured at two reference frequencies, using a 3-interval, 2-alternative forced-choice, adaptive staircase procedure. The two reference frequencies were selected using each participant’s frequency allocation table and were centered in the frequency band of an electrode that included 500 or 2000 Hz, corresponding to the apical electrode or the middle electrode, respectively. The ACC was evoked with pure tones of the same two reference frequencies with varying frequency increases: within the frequency band of the middle or the apical electrode (+0.25 electrode step), and steps to the center frequency of the first (+1), second (+2), and third (+3) adjacent electrodes. RESULTS: Reproducible ACCs were recorded in 17 out of 19 subjects. Most successful recordings were obtained with the largest frequency change (+3 electrode step). Larger frequency changes resulted in shorter N1 latencies and larger N1-P2 amplitudes. In both unilaterally and bilaterally deaf subjects, the N1 latency and N1-P2 amplitude of the CI ears correlated to speech perception as well as frequency discrimination, that is, short latencies and large amplitudes were indicative of better speech perception and better frequency discrimination. No significant differences in ACC latencies or amplitudes were found between the CI ears of the unilaterally and bilaterally deaf subjects, but the CI ears of the unilaterally deaf subjects showed substantially longer latencies and smaller amplitudes than their contralateral normal-hearing ears. CONCLUSIONS: The ACC latency and amplitude evoked by tone frequency changes correlate well to frequency discrimination and speech perception capabilities of CI users. For patients unable to reliably perform behavioral tasks, the ACC could be of added value in assessing hearing performance

    Can the hydroxyapatite coated skin-penetrating abutment for bone conduction hearing implants integrate with the surrounding skin?

    Get PDF
    AbstractIntroductionPercutaneous implants such as bone conduction hearing implants suffer from complications that include inflammation of the surrounding skin. A sealed skin-abutment interface can prevent the ingress of bacteria, which should reduce the occurrence of peri-abutment dermatitis. It was hypothesized that a hydroxyapatite (HA) coated abutment in conjunction with soft tissue preservation surgery should enable integration with the adjacent skin. Previous research has confirmed that integration is never achieved with as-machined titanium abutments. Here, we investigate, in vivo, if skin integration is achievable in patients using a HA-coated abutment. Materials and MethodsOne titanium abutment (control) and one HA-coated abutment (case) together with the surrounding skin were surgically retrieved from two patients who had a medical indication for this procedure. Histological sections of the skin were investigated using light microscopy. The abutment was qualitatively analyzed using scanning electron microscopy (SEM). Results The titanium abutment only had a partial and thin layer of attached amorphous biological material. The HA-coated abutment was almost fully covered by a pronounced thick layer of skin components that were organized and composed of different interconnected structural layers. ConclusionProof-of-principle evidence that the HA-coated abutment can achieve integration with the surrounding skin was presented for the first time

    A retrospective cohort study of adverse event assessment during anesthesia-related procedures for cochlear implant candidacy assessment and cochlear implantation in infants and toddlers

    Get PDF
    Background: Cochlear implantation in children with sensorineural hearing loss is preferably performed at youngest age because early auditory input is essential to prevent neural plasticity decline. In contrast, the rate of anesthetic adverse events is increased during infancy. Therefore, to provide recommendations regarding an optimal pediatric implantation age, these possible anesthetic risks in infants need to be taken into account. Aims: This study aimed at assessing the relation between the age at cochlear implant surgery and anesthetic and surgical adverse events. Secondary aims were to evaluate anesthetic and surgical adverse events in relation to (a) the number of preoperative anesthesia-related procedures for cochlear implant candidacy assessment and (b) the anesthetic maintenance agent (total intravenous anesthesia versus inhalation anesthesia) during implantation. Methods: We executed a retrospective cohort study to evaluate cochlear implantation performed in infants and toddlers between January 2008 and July 2015 in a tertiary pediatric center. We compared anesthetic and surgical adverse events between age-at-implantation (0-12 and 12-24 months of age) groups. Furthermore, we assessed whether anesthetic adverse events occurred during preoperative anesthesia-related procedures for cochlear implant candidacy assessment. Results: Forty-six cochlear implantations were performed in 43 patients requiring 42 preoperative anesthesia-related procedures. Nineteen cochlear implantations (41.3%) were performed during infancy. During implantation, the maintenance agent was either sevoflurane (n = 22) or propofol (n = 24). None of the patients encountered major anesthetic adverse events, whereas minor adverse events occurred during 34 cochlear implantations. Those attributed to surgery occurred following six implantations. Neither the age at implantation nor the anesthetic maintenance agent was significantly related to the occurrence of both types of adverse events. Conclusions: Adverse events occur independent of the age at implantation, the number of anesthetic preoperative procedures, and the type of anesthetic maintenance agent in patients who received a cochlear implant before 24 months of age
    corecore