223 research outputs found

    Drug-induced Sleep Endoscopy:Are there Predictors for Failure of Oral Appliance Treatment?

    Get PDF
    Introduction In the literature, evidence is lacking on the predictive value of drug-induced sleep endoscopy (DISE) for oral appliance treatment (OAT). Objectives The aim of the present study is to evaluate whether DISE with concomitant mandibular advancement maneuver can predict failure of OAT. Methods An observational retrospective study including patients diagnosed with obstructive sleep apnea (OSA) who previously received OAT. Results of DISE were analyzed in a group with documented OAT failure (apnea-hypopnea index [AHI] > 10 events/hour or  50% reduction). The upper airway was assessed using the velum, oropharynx, tongue base, epiglottis (VOTE) classification. Additionally, a mandibular advancement maneuver, manually protruding the mandible by performing a jaw thrust, was performed to mimic the effect of OAT. Results The present study included 50 patients with OAT failure and 20 patients with OAT benefit. A subgroup analysis of patients with OAT failure and an AHI < 30 events/hour included 26 patients. In the OAT failure group, 74% had a negative jaw thrust maneuver. In the subgroup with an AHI < 30 events/hour, 76.9% had a negative jaw thrust maneuver. In the OAT benefit group, 25% had a negative jaw thrust maneuver (p < 0.001). Conclusions A negative jaw thrust maneuver during DISE can be a valuable predictor for OAT failure, independent of AHI. Drug-induced sleep endoscopy should be considered as a diagnostic evaluation tool before starting OAT

    The impact of injury of the chorda tympani nerve during primary stapes surgery or cochlear implantation on taste function, quality of life and food preferences:A study protocol for a double-blind prospective prognostic association study

    Get PDF
    BACKGROUND: The chorda tympani nerve (CTN) is a mixed nerve, which carries sensory and parasympathetic fibres. The sensory component supplies the taste sensation of the anterior two-thirds of the ipsilateral side of the tongue. During middle ear surgery the CTN is exposed and frequently stretched or sacrificed, because it lacks a bony covering as it passes through the middle ear. Injury may cause hypogeusia, ageusia or altered taste sensation of the ipsilateral side of the tongue. To date, there is no consensus regarding which type of CTN injury (sacrificing or stretching), during middle ear surgery, leads to the least burden for the patient.METHODS: A double-blind prospective prognostic association study was designed in a single medical centre in the Netherlands to determine the effect of CTN injury on postoperative taste disturbance and quality of life. 154 patients, who will undergo primary stapes surgery or cochlear implantation will be included. The taste sensation, food preferences and quality of life of these patients will be evaluated preoperatively and at one week, six weeks and six months postoperatively using the Taste Strip Test, Electrogustometry, supplementary questionnaire on taste disturbance, Macronutrient and Taste Preference Ranking Task, Appetite, Hunger and Sensory Perception questionnaire and Questionnaire of Olfactory Disorders to assess the association of these outcomes with CTN injury. Evaluation of olfactory function will only take place preoperatively and at one week postoperatively using the Sniffin' Sticks. The patient and outcome assessor are blinded to the presence or absence of CTN injury.DISCUSSION: This study is the first to validate and quantify the effect of chorda tympani nerve injury on taste function. The findings of this study may lead to evidence-based proof of the effect of chorda tympani injury on taste function with consequences for surgical strategies.TRIAL REGISTRATION: Netherlands Trial Register NL9791. Registered on 10 October 2021.</p

    The Vestibular Implant: Quo Vadis?

    Get PDF
    Objective: To assess the progress of the development of the vestibular implant (VI) and its feasibility short-term. Data sources: A search was performed in Pubmed, Medline, and Embase. Key words used were “vestibular prosth*” and “VI.” The only search limit was language: English or Dutch. Additional sources were medical books, conference lectures and our personal experience with per-operative vestibular stimulation in patients selected for cochlear implantation. Study selection: All studies about the VI and related topics were included and evaluated by two reviewers. No study was excluded since every study investigated different aspects of the VI. Data extraction and synthesis: Data was extracted by the first author from selected reports, supplemented by additional information, medical books conference lectures. Since each study had its own point of interest with its own outcomes, it was not possible to compare data of different studies. Conclusion: To use a basic VI in humans seems feasible in the very near future. Investigations show that electric stimulation of the canal nerves induces a nystagmus which corresponds to the plane of the canal which is innervated by the stimulated nerve branch. The brain is able to adapt to a higher baseline stimulation, while still reacting on a dynamic component. The best response will be achieved by a combination of the optimal stimulus (stimulus profile, stimulus location, precompensation), complemented by central vestibular adaptation. The degree of response will probably vary between individuals, depending on pathology and their ability to adapt

    Endoscopic vs. microscopic stapes surgery:An anatomical feasibility study

    Get PDF
    OBJECTIVES: To investigate the feasibility of the endoscopic approach vs. microscopic approach during stapes surgery, focusing on the visualization of the important anatomical structures of the middle ear, the volume of the resected scutum and chorda tympani (CT) injury. METHODS: Fresh frozen human cadaveric heads underwent two stapes surgeries using an operating microscope on one ear and an endoscope on the other ear. The surgeon documented the visualization of critical landmarks, as well as exposure and injury of the CT. The volume of resected scutum was evaluated using cone beam computed tomography scanning and three-dimensional imaging. RESULTS: We performed endoscopic stapes surgery in 10 ears and microscopic stapes surgery in 11 ears. A stapes prosthesis was placed in all ears. The volume of bony scutum resection was significantly lower in the endoscopic group (median = 2.20 mm 3, IQR = 4.17) than in the microscopic group (median 13.25 mm 3, IQR = 8.71). No scutum was removed in two endoscopic ears, while scutum was removed in all microscopic ears. The endoscopic and microscopic group had similar CT injury. CONCLUSIONS: This study showed that the endoscopic stapes surgery procedure is feasible and might be less invasive than microscopic stapes surgery. Future clinical prospective and functional studies will be needed to support our findings

    Systematic review:Validity, reliability, and diagnostic accuracy of the electrogustometer

    Get PDF
    OBJECTIVE: What are the electrogustometer's (EGM) validity, reliability, and diagnostic accuracy in assessing taste sensation in adults compared to other taste tests?DATA SOURCES: PubMed Medline, Elseviers's Embase, and the six databases of Cochrane Library.METHODS: We conducted a systematic search on December 20, 2022, consisting of synonyms for EGM. We considered randomized controlled trials and observational studies with original data for inclusion if they included adults who underwent electrogustometry. Articles were excluded if no analysis regarding validity, reliability, or diagnostic accuracy had been performed or if these analyses could not be performed with the published data.RESULTS: Nineteen articles discussing 18 studies were included for data extraction. The included studies carry a high risk of bias. Overall, the association between a variety of reference taste tests and EGM was moderate or weak with correlation coefficients ranging from -0.51 to 0.40 with one outlier of -0.74 found in one study correlating EGM and taste solutions. Test-retest reliability was good with reported correlation coefficients between 0.78 and 1.0. The sensitivity, specificity, PPV, and NPV of EGM in identifying abnormal taste function varied widely between the four studies on diagnostic accuracy.CONCLUSION: The included studies in this review lack the required standards regarding study design to draw firm conclusions about the validity, reliability, and diagnostic accuracy of the EGM. Future research is needed to assess these measurement properties. Based on the reported results, we would not recommend using the EGM as a screening test for taste disturbance in clinical practice.LEVEL OF EVIDENCE: NA.</p

    Systematic review:Validity, reliability, and diagnostic accuracy of the electrogustometer

    Get PDF
    OBJECTIVE: What are the electrogustometer's (EGM) validity, reliability, and diagnostic accuracy in assessing taste sensation in adults compared to other taste tests?DATA SOURCES: PubMed Medline, Elseviers's Embase, and the six databases of Cochrane Library.METHODS: We conducted a systematic search on December 20, 2022, consisting of synonyms for EGM. We considered randomized controlled trials and observational studies with original data for inclusion if they included adults who underwent electrogustometry. Articles were excluded if no analysis regarding validity, reliability, or diagnostic accuracy had been performed or if these analyses could not be performed with the published data.RESULTS: Nineteen articles discussing 18 studies were included for data extraction. The included studies carry a high risk of bias. Overall, the association between a variety of reference taste tests and EGM was moderate or weak with correlation coefficients ranging from -0.51 to 0.40 with one outlier of -0.74 found in one study correlating EGM and taste solutions. Test-retest reliability was good with reported correlation coefficients between 0.78 and 1.0. The sensitivity, specificity, PPV, and NPV of EGM in identifying abnormal taste function varied widely between the four studies on diagnostic accuracy.CONCLUSION: The included studies in this review lack the required standards regarding study design to draw firm conclusions about the validity, reliability, and diagnostic accuracy of the EGM. Future research is needed to assess these measurement properties. Based on the reported results, we would not recommend using the EGM as a screening test for taste disturbance in clinical practice.LEVEL OF EVIDENCE: NA.</p

    The effect of the surgical approach and cochlear implant electrode on the structural integrity of the cochlea in human temporal bones

    Get PDF
    Cochlear implants (CI) restore hearing of severely hearing-impaired patients. Although this auditory prosthesis is widely considered to be very successful, structural cochlear trauma during cochlear implantation is an important problem, reductions of which could help to improve hearing outcomes and to broaden selection criteria. The surgical approach in cochlear implantation, i.e. round window (RW) or cochleostomy (CO), and type of electrode-array, perimodiolar (PM) or lateral wall (LW), are variables that might influence the probability of severe trauma. We investigated the effect of these two variables on scalar translocation (STL), a specific type of severe trauma. Thirty-two fresh frozen human cadaveric ears were evenly distributed over four groups receiving either RW or CO approach, and either LW or PM array. Conventional radiological multiplanar reconstruction (MPR) was compared with a reconstruction method that uncoils the spiral shape of the cochlea (UCR). Histological analysis showed that RW with PM array had STL rate of 87% (7/8), CO approach with LW array 75% (6/8), RW approach with LW array 50% (4/8) and CO approach with PM array 29% (2/7). STL assessment using UCR showed a higher inter-observer and histological agreement (91 and 94% respectively), than that using MPR (69 and 74% respectively). In particular, LW array positions were difficult to assess with MPR. In conclusion, the interaction between surgical approach and type of array should be preoperatively considered in cochlear implant surgery. UCR technique is advised for radiological assessment of CI positions, and in general it might be useful for pathologies involving the inner ear or other complex shaped bony tubular structures
    corecore