10 research outputs found

    N-acetylcysteine treats intravenous amiodarone induced liver injury

    Get PDF
    We report a case of intravenous (IV) amiodarone drug induced liver injury (DILI). The patient received IV N-acetylcysteine (NAC) which resulted in a rapid improvement in liver enzymes. While the specific mechanisms for the pathogenesis of IV amiodarone DILI and the therapeutic action of IV NAC are both unknown, this case strongly implies at least some commonality. Because IV amiodarone is indicated for the treatment of serious cardiac arrhythmias in an intensive care unit setting, some degree of ischemic hepatitis is likely a cofactor in most cases

    Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults

    No full text
    Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μmol L(-1) (interquartile range (IQR), 3-18) versus 46 μmol L(-1) (IQR, 23-66) for cirrhotic participants. Median breath ammonia was 379 pmol mL(-1) CO2 (IQR, 265-765) for healthy versus 350 pmol mL(-1) CO2 (IQR, 180-1013) for cirrhotic participants. CV was 17  ±  6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia

    Repeated Measures of Blood and Breath Ammonia in Response to Control, Moderate and High Protein Dose in Healthy Men

    Get PDF
    Abstract Ammonia physiology is important to numerous disease states including urea cycle disorders and hepatic encephalopathy. However, many unknowns persist regarding the ammonia response to common and potentially significant physiologic influences, such as food. Our aim was to evaluate the dynamic range of ammonia in response to an oral protein challenge in healthy participants. We measured blood and breath ammonia at baseline and every hour for 5.5 hours. Healthy men (N = 22, aged 18 to 24 years) consumed a 60 g protein shake (high dose); a subset of 10 consumed a 30 g protein shake (moderate dose) and 12 consumed an electrolyte drink containing 0 g protein (control). Change in blood ammonia over time varied by dose (p = 0.001). Difference in blood ammonia was significant for control versus high (p = 0.0004) and moderate versus high (p = 0.03). Change in breath ammonia over time varied by dose (p < 0.0001). Difference in breath ammonia was significant for control versus moderate (p = 0.03) and control versus high (p = 0.0003). Changes in blood and breath ammonia were detectable by fast, minimally-invasive (blood) or non-invasive (breath) point-of-care ammonia measurement methods. These pilot data may contribute to understanding normal ammonia metabolism. Novel measurement methods may aid research into genetic and metabolic ammonia disorders

    Geschlechtstypische Berufswahl: Begabungszuschreibungen, Aspirationen und Institutionen

    Full text link
    Der vorliegende Beitrag geht der Frage nach, ob geschlechterstereotype Begabungszuschreibungen von Eltern am Ende der Pflichtschulzeit einen Einfluss darauf haben, dass junge Frauen und Männer drei Jahre später, mit 18 Jahren, eine geschlechtstypische Berufsausbildung absolvieren. Die Daten stammen von der mittleren Kohorte der Schweizer Kinder- und Jugendlängsschnittstudie COCON und wurden 2006 und 2009 erhoben, als die Jugendlichen 15 bzw. 18 Jahre alt waren. Die Ergebnisse multinominaler Logit-Modelle zeigen, dass geschlechterstereotype elterliche Fähigkeitszuschreibungen die Wahl unterschiedlicher Typen von Frauen- und Männerberufen begünstigen. Zudem kommt geschlechtstypischen Aspirationen sowie institutionellen Zuweisungsprozessen aufgrund schulischer Qualifikationen eine große Bedeutung zu
    corecore