6 research outputs found

    Synovitis maps for the assessment of inflammatory diseases of the hand

    Get PDF
    Objectives: To compare accuracy and review times of FLASH-MRI-derived synovitis maps (SM) with conventional MR images (cMRI) in the assessment of articular synovitis and tenosynovitis of the hand. Methods: 80 hands in 40 patients (mean age, 48years; range, 15-72years) were assessed for synovitis on cMRI and SM by two readers independently. Reporting times and diagnostic confidence (scale: 1 = least, 5 = most confident) were measured. Results from an assessment of a panel of senior musculoskeletal radiologists served as the standard of reference. Results: Sensitivity and specificity for the detection of articular synovitis were 0.91/1.00 (R1) and 1.00/0.67 (R2) on cMRI and 0.87/0.75 (R1) and 0.91/0.45 (R2) on SM and for the detection of tenosynovitis 0.95/0.63 (R1) and 0.67/0.79 (R2) on cMRI and 0.67/0.89 (R1) and 0.38/1.00 (R2) on SM. Mean review times (cMRI/SM, sec) were 142/37 (R1) and 167/25 (R2). Mean diagnostic confidence (cMRI/SM) was 3.7/3.4 (R1) and 3.2/3.5 (R2) for articular synovitis and 4.0/4.0 (R1), 3.3/3.7 (R2) for tenosynovitis. Conclusion: Synovitis maps provide a comparable diagnostic accuracy to conventional MR images in the assessment of articular synovitis and tenosynovitis of the hand. Because of short review times, synovitis maps provide a fast overview of locations with synovial enhancemen

    Hypothenar hammer syndrome: caused by a muscle anomaly? A case report with review of the literature

    Full text link
    The hypothenar hammer syndrome (HHS) is a rare entity of secondary Raynaud's phenomenon. The blunt hypothenar trauma causes a lesion of the vessel wall with a consecutive thrombosis or aneurysm of the ulnar artery at the Guyon's canal. Different risk factors are discussed such as nicotine abuse, or a muscle anomaly in the Guyon's canal. To date, there are five case reports published about muscle anomalies and HHS. We present a case of a 51-year-old shipbuilder with a unilateral HHS on his right dominant hand with a bilateral muscle anomaly. We successfully treated the patient by resection of the aneurysm without a resection of the atypical muscle

    Feasibility and preliminary results of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction

    Full text link
    PURPOSE To evaluate the feasibility and performance of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction. METHODS This prospective study included 28 wrists of 27 patients evaluated with SPECT/CT arthrography and MR arthrography. Iodine contrast medium and gadolinium were injected into the distal radioulnar and midcarpal joints. Late-phase SPECT/CT was performed 3.5 h after intravenous injection of approximately 650 MBq (99m)Tc-DPD. MR and SPECT/CT images were separately reviewed in relation to bone marrow oedema, radionuclide uptake, and tears in the scapholunate (SL) and lunotriquetral (LT) ligaments and triangular fibrocartilage complex (TFCC), and an overall diagnosis of ulnar impaction. MR, CT and SPECT/CT imaging findings were compared with each other, with the surgical findings in 12 patients and with clinical follow-up. RESULTS The quality of MR arthrography and SPECT/CT arthrography images was fully diagnostic in 23 of 28 wrists (82%) and 25 of 28 wrists (89%), respectively. SPECT/CT arthrography was not diagnostic for ligament lesions due to insufficient intraarticular contrast in one wrist. MR and SPECT/CT images showed concordant findings regarding TFCC lesions in 22 of 27 wrists (81%), SL ligament in 22 of 27 wrists (81%) and LT ligament in 23 of 27 wrists (85%). Bone marrow oedema on MR images and scintigraphic uptake were concordant in 21 of 28 wrists (75%). MR images showed partial TFCC defects in four patients with normal SPECT/CT images. MR images showed bone marrow oedema in 4 of 28 wrists (14%) without scintigraphic uptake, and scintigraphic uptake was present without MR bone marrow oedema in three wrists (11%). Regarding diagnosis of ulnar impaction the concordance rate between CT and SPECT/CT was 100% and reached 96% (27 of 28) between MR and SPECT/CT arthrography. The sensitivity and specificity of MR, CT and SPECT/CT arthrography were 93%, 100% and 100%, and 93%, 93% and 93%, respectively. CONCLUSION SPECT/CT arthrography of the wrist is feasible. Regarding diagnosis of ulnar impaction we found a high concordance with MR arthrography. SPECT/CT arthrography of the wrist is an alternative to MR arthrography in patients with contraindications to MR imaging

    Synovitis maps for the assessment of inflammatory diseases of the hand

    Full text link
    OBJECTIVES: To compare accuracy and review times of FLASH-MRI-derived synovitis maps (SM) with conventional MR images (cMRI) in the assessment of articular synovitis and tenosynovitis of the hand. METHODS: 80 hands in 40 patients (mean age, 48 years; range, 15-72 years) were assessed for synovitis on cMRI and SM by two readers independently. Reporting times and diagnostic confidence (scale: 1 = least, 5 = most confident) were measured. Results from an assessment of a panel of senior musculoskeletal radiologists served as the standard of reference. RESULTS: Sensitivity and specificity for the detection of articular synovitis were 0.91/1.00 (R1) and 1.00/0.67 (R2) on cMRI and 0.87/0.75 (R1) and 0.91/0.45 (R2) on SM and for the detection of tenosynovitis 0.95/0.63 (R1) and 0.67/0.79 (R2) on cMRI and 0.67/0.89 (R1) and 0.38/1.00 (R2) on SM. Mean review times (cMRI/SM, sec) were 142/37 (R1) and 167/25 (R2). Mean diagnostic confidence (cMRI/SM) was 3.7/3.4 (R1) and 3.2/3.5 (R2) for articular synovitis and 4.0/4.0 (R1), 3.3/3.7 (R2) for tenosynovitis. CONCLUSION: Synovitis maps provide a comparable diagnostic accuracy to conventional MR images in the assessment of articular synovitis and tenosynovitis of the hand. Because of short review times, synovitis maps provide a fast overview of locations with synovial enhancement
    corecore