26 research outputs found

    The Role of Device Diagnostic Algorithms in the Assessment and Management of Patients with Systolic Heart Failure: A Review

    Get PDF
    Hospitalization due to heart failure (HF) exacerbation represents a major burden in health care and portends a poor long-term prognosis for patients. As a result, there is considerable interest to develop novel tools and strategies to better detect onset of volume overload, as HF hospitalizations may be reduced if appropriate interventions can be promptly delivered. One such innovation is the use of device-based diagnostic parameters in HF patients with implantable cardioverter defibrillators (ICD) and/or cardiac resynchronization therapy (CRT) devices. These diagnostic algorithms can effectively monitor and detect changes in patients' HF status, as well as predict one's risk of HF hospitalization. This paper will review the role of these device diagnostics parameters in the assessment and management of HF patients in ambulatory settings. In addition, the integration of these novel algorithms in existing HF disease management models will be discussed

    Defibrillator Shocks and Their Impact on Objective and Subjective Patient Outcomes: Results from the Painfree SST Clinical Trial

    Get PDF
    BACKGROUND: The impact of ICD shock on device-measured activity and patient reported outcomes is unknown. OBJECTIVE: The purpose of this study was to analyze the acute and long-term effects of ICD shock on objective behavioral data (i.e., device-based physical activity) and subjective patient reported outcomes (e.g., quality of life and shock anxiety). METHODS: The PainFree SST clinical trial included 2,770 patients with a single or dual-chamber ICD, or cardiac resynchronization defibrillator (CRT-D) who were followed for 22 ± 9 months. Participants completed measures of quality of life (EuroQol 5-D [EQ5D]) and shock anxiety (Florida Shock Anxiety Scale [FSAS]) at baseline, bi-annual visits, and monthly for 6 months following an ICD shock. Daily physical activity data were obtained from a built-in device accelerometer. RESULTS: Average daily activity was 185.3 ± 119.4 minutes/day. Activity was significantly reduced after an ICD shock (p<0.0001) and recovered to a normal level after approximately 90 days. ICD shock was also associated with decreased quality of life (EQ5D Health Score) and increased EQ5D anxiety scores, but it did not impact mobility, self-care, activity, or pain. Similarly, shock anxiety (FSAS) increased in shocked patients and remained significantly elevated at 24 months, regardless of appropriate or inappropriate shock delivery. CONCLUSIONS: ICD shocks have a long-lasting, adverse impact on both objective, device-measured physical activity and subjective patient reported outcomes of quality of life and shock anxiety. Successful management of ICD patients requires attention to clinically relevant behavioral and psychological outcomes to expedite recovery and return to activities of daily living

    Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis

    Get PDF
    Aims: Single-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs from the literature. Methods and results: PubMed, Embase, and Cochrane Library were searched for full text articles with IS rates. Poisson distribution estimated proportion of patients with ISs; rates were annualized based on follow-up duration. Random effects meta-analysis accounted for study-to-study variation. Out of 3264 articles, 16 qualified for the meta-analysis. Across studies, 6.4% [95% confidence interval (CI) 5.1-7.9%] of patients received an IS per year. Meta-regression analyses demonstrated that IS rates were lower in more recent studies [rate ratio (RR) per year: 0.93, 95% CI: 0.87-0.98; P = 0.01] and trended lower in studies with longer follow-up (RR per year: 0.78, 95% CI: 0.60-1.01; P = 0.06). Use of S-ICDs (RR: 1.81, 95% CI: 0.86-3.81; P = 0.12) and ventricular tachycardia zone programmed on (RR: 1.13, 95% CI: 0.65-1.97; P = 0.66) were not associated with a significantly increased change in risk. The IS rate observed in one of the more recent studies was significantly lower than predicted after accounting for covariates (RR: 0.29, 95% CI: 0.14-0.60; P < 0.001). Conclusions: A comprehensive review of the literature shows that 6.4% of patients with ICDs experienced their first IS annually. One of the 16 studies was better than predicted with the lowest reported rate (1.9%) and could not be explained by timing of the study or other covariates

    Estimating the incidence of atrial fibrillation in single-chamber implantable cardioverter defibrillator patients

    Full text link
    BACKGROUND Atrial arrhythmias are associated with major adverse cardiovascular events. Recent reports among implantable cardioverter defibrillator (ICD) patients have demonstrated a high prevalence of atrial fibrillation (AF), predominantly in dual-chamber recipients. AF incidence among patients with single-chamber systems (approximately 50% of all ICDs) is currently unknown. The objective was to estimate the prevalence of new-onset AF among single-chamber ICD patients by observing the rates of new atrial tachycardia (AT)/AF among a propensity scoring matched cohort of dual-chamber ICD patients from the PainFree SST study, to better inform screening initiatives. METHODS Among 2,770 patients enrolled, 1,862 single-chamber, dual-chamber, and cardiac resynchronization therapy (CRT) subjects with no prior history of atrial tachyarrhythmias were included. Daily AT/AF burden was estimated using a propensity score weighted model against data from dual-chamber ICDs. RESULTS Over 22 ± 9 months of follow-up, the estimated incidence of AT/AF - lasting at least 6 minutes, 6 hours and 24 hours per day - in the single-chamber cohort was 22.0%, 9.8% and 6.3%, whereas among dual-chamber patients, the prevalence was 26.6%, 13.1%, and 7.1%, respectively. Initiation of oral anticoagulation (OAC) was estimated to occur in 9.8% of the propensity matched single-chamber cohort, which was higher than the actual observed rate of 6.0%. Stroke and transient ischemic attack (TIA) occurred at low rates in all device subgroups. CONCLUSIONS Atrial arrhythmias occur frequently, and significant underutilization of anticoagulation is suggested in single-chamber ICD recipients. Routine screening for AF should be considered among single-chamber ICD recipients. This article is protected by copyright. All rights reserved

    SVT discrimination algorithms significantly reduce the rate of inappropriate therapy in the setting of modern day delayed high-rate detection programming

    Full text link
    BACKGROUND Contemporary ICD programming involving delayed high-rate detection and use of SVT discriminators has significantly reduced the rate of inappropriate shocks. The extent to which SVT algorithms alone reduce inappropriate therapies is poorly understood. METHODS AND RESULTS PainFree SST enrolled 2,770 patients with a single or dual-chamber ICD or cardiac resynchronization defibrillator. Patients were followed for 22±9 months with SVT discriminators on in 96% of patients. Sustained ventricular tachyarrhythmias and SVT episodes were adjudicated by an independent physician committee. For this analysis, all episodes were subjected to post-processing computer simulation with SVT discriminators off with and without delayed high-rate detection criteria (VF zone only, 30/40@320ms). There were 3,282 adjudicated SVT episodes of which 115 resulted in an ICD shock and 113 received only ATP (2-year inappropriate shock and therapy rates of 3.1% and 4.1%). Therapy was appropriately withheld for the remaining 3,054 SVT episodes. With both SVT discriminators and delayed high-rate detection simulated off, the 2-year inappropriate therapy rate would have been 22.9% (Hazard Ratio [HR]=6.24, 95% confidence interval [CI]: 5.20-7.49). With SVT discriminators simulated off and delayed high-rate detection simulated on in all patients, the 2-year rate would have been 6.4% (HR=1.63, CI: 1.44-1.85). CONCLUSIONS Use of SVT discriminators has a significant role in reducing the rate of inappropriate ICD therapy even in the setting of delayed high-rate detection settings. Deactivating SVT discriminators would have resulted in an overall increase in the inappropriate ICD therapy rate by 63% and 524% with and without delayed high-rate detection programming, respectively. This article is protected by copyright. All rights reserved

    Double transseptal puncture for catheter ablation of atrial fibrillation: safety of the technique and its use in the outpatient setting

    Get PDF
    Introduction. For pulmonary vein isolation in patients with atrial fibrillation (AF), some centers use the double transseptal puncture technique for catheter access in order to facilitate catheter manipulation within the left atrium. However, no safety data has so far been published using this approach. Method. 269 ablation procedures were performed in 243 patients (mean age 56.6 ± 9.3 years, 75% men) using the double transseptal puncture for catheter access in all cases. Patients were considered for ablation of paroxysmal (80%), persistent (19%), and permanent (1%) AF. 230 procedures were performed on an outpatient basis (85.5%), and 26 were repeat procedures (9.7%). Results. The double transseptal puncture catheter access was successfully achieved in all patients. The procedural success with the endpoint of pulmonary vein isolation was reached in 255 procedures (95%). A total of 1048 out of 1062 pulmonary veins (99%) were successfully isolated. Major complications occurred in eight patients (3.0%). Of these, seven patients (2.6%) had pericardial effusion requiring percutaneous drainage, and one patient (0.4%) suffered a minor reversible stroke. One patient (0.4%) had a minor air embolism with transient symptoms. Conclusion. The double transseptal puncture catheterization technique allows easy catheter manipulation within the left atrium to reach the goal of acute procedural success in AF ablation. Procedure-related complications are rare, and the technique can be used safely for AF ablation in the outpatient setting