20 research outputs found

    Assessing the Retrofit Potential of Building Control Systems

    Get PDF
    It is well known that building control systems frequently under-perform, leading to wasted energy and poor space conditions for occupants. There are many reasons for this, including insufficient design or commissioning, deterioration of equipment over time, changes in building usage and poor maintenance. Therefore, building control systems are prime candidates for retrofits and upgrades. Such activities, though, can be very challenging in their own right. For example, information regarding the design intent and current control logic may be difficult or impossible to obtain due to lack of documentation, proprietary data and communication formats or unrecorded modifications. In addition, there is a great deal of variability in control system configuration and components, so each potential retrofit activity can become a time-consuming and expensive operation requiring a high level of expertise. To reduce these barriers to implementing building control system retrofits, a method has been developed to assist in the identification and assessment of building control system operation and retrofit potential. The components of the method include a system identification process that categorizes the building by type and usage, then it produces an information model of the control system, which can be compared to other similar buildings by category. Control system requirements to meet two performance levels are provided, namely current best practice and high performance, along with suggested control technology packages to achieve the desired level of performance. This paper describes the method and demonstrates it via a case study

    Anti-HER2 IgY antibody-functionalized single-walled carbon nanotubes for detection and selective destruction of breast cancer cells

    Get PDF
    BACKGROUND: Nanocarrier-based antibody targeting is a promising modality in therapeutic and diagnostic oncology. Single-walled carbon nanotubes (SWNTs) exhibit two unique optical properties that can be exploited for these applications, strong Raman signal for cancer cell detection and near-infrared (NIR) absorbance for selective photothermal ablation of tumors. In the present study, we constructed a HER2 IgY-SWNT complex and demonstrated its dual functionality for both detection and selective destruction of cancer cells in an in vitro model consisting of HER2-expressing SK-BR-3 cells and HER2-negative MCF-7 cells. METHODS: The complex was constructed by covalently conjugating carboxylated SWNTs with anti-HER2 chicken IgY antibody, which is more specific and sensitive than mammalian IgGs. Raman signals were recorded on Raman spectrometers with a laser excitation at 785 nm. NIR irradiation was performed using a diode laser system, and cells with or without nanotube treatment were irradiated by 808 nm laser at 5 W/cm(2 )for 2 min. Cell viability was examined by the calcein AM/ethidium homodimer-1 (EthD-1) staining. RESULTS: Using a Raman optical microscope, we found the Raman signal collected at single-cell level from the complex-treated SK-BR-3 cells was significantly greater than that from various control cells. NIR irradiation selectively destroyed the complex-targeted breast cancer cells without harming receptor-free cells. The cell death was effectuated without the need of internalization of SWNTs by the cancer cells, a finding that has not been reported previously. CONCLUSION: We have demonstrated that the HER2 IgY-SWNT complex specifically targeted HER2-expressing SK-BR-3 cells but not receptor-negative MCF-7 cells. The complex can be potentially used for both detection and selective photothermal ablation of receptor-positive breast cancer cells without the need of internalization by the cells. Thus, the unique intrinsic properties of SWNTs combined with high specificity and sensitivity of IgY antibodies can lead to new strategies for cancer detection and therapy

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Measurement of inclusive jet and dijet cross-sections in proton-proton collisions at s √ =13 TeV with the ATLAS detector

    Get PDF
    Inclusive jet and dijet cross-sections are measured in proton-proton collisions at a centre-of-mass energy of 13 TeV. The measurement uses a dataset with an integrated luminosity of 3.2 fb−1 recorded in 2015 with the ATLAS detector at the Large Hadron Collider. Jets are identified using the anti-kt algorithm with a radius parameter value of R = 0.4. The inclusive jet cross-sections are measured double-differentially as a function of the jet transverse momentum, covering the range from 100 GeV to 3.5 TeV, and the absolute jet rapidity up to |y| = 3. The double-differential dijet production cross-sections are presented as a function of the dijet mass, covering the range from 300 GeV to 9 TeV, and the half absolute rapidity separation between the two leading jets within |y| < 3, y∗, up to y∗ = 3. Next-to-leading-order, and next-to-next-to-leading-order for the inclusive jet measurement, perturbative QCD calculations corrected for non-perturbative and electroweak effects are compared to the measured cross-sections

    Measurement of jet fragmentation in Pb+Pb and pppp collisions at sNN=2.76\sqrt{{s_\mathrm{NN}}} = 2.76 TeV with the ATLAS detector at the LHC

    Get PDF

    Agent-Based Approaches for Adaptive Building HVAC System Control

    Get PDF

    The Effect of Electric Load Profiles on the Performance of Off-Grid Residential Hybrid Renewable Energy Systems

    No full text
    This paper investigates the energy performance of off-grid residential hybrid renewable electric power systems, particularly the effect of electric load profiles on the ability to harvest available solar energy and avoid the consumption of auxiliary energy in the form of propane. The concepts are illustrated by an analysis of the energy performance of electric and propane-fired refrigerators. Off-grid electric power systems frequently incorporate a renewable source, such as wind or solar photovoltaic (PV), with a back-up power provided by a propane fueled motor/generator. Among other design decisions, residential consumers face the choice of employing an electric refrigerator with a conventional vapor compression refrigeration system, or a fuel-fired refrigerator operating as an absorption refrigeration system. One interesting question is whether it is more advantageous from an energy perspective to use electricity to run the refrigerator, which might be provided by some combination of the PV and propane motor/generator, thereby taking advantage of the relatively higher electric refrigerator Coefficient of Performance (COP) and free solar energy but having to accept a low electrical conversion efficiency of the motor/generator, or use thermal energy from the combustion of propane to produce the refrigeration effect via an absorption system, albeit with a much lower COP. The analysis is complicated by the fact that most off-grid renewable electrical power systems utilize a battery bank to provide electrical power when it is not available from the wind turbine or PV system, so the state of charge of the battery bank will have a noticeable impact on what energy source is available at any moment in time. Daily electric load profiles combined with variable solar energy input determine the state of charge of the battery bank, with the degree of synchronization between the two being a critical factor in determining performance. The annual energy usage and fuel input depend strongly on the ability to make use of the renewable sources in real time to avoid battery bank conversion losses and dumping of excess electrical power, as well as to have sufficient battery storage capacity to minimize the need for operation of the motor/generator to meet electric loads which occur during periods when the renewable energy is not available

    MODELING AND SIMULATION OF BUILDING ECONOMIZER AND ENERGY RECOVERY SYSTEMS FOR OPTIMUM PERFORMANCE

    No full text
    ABSTRACT This paper describes how building economizer and energy/enthalpy recovery system control and operation can be modelled and simulated to evaluate and optimize their performance. A improved method to determine optimum temperature setpoints and outdoor air fractions is discussed and demonstrated. Through the simulation, the new strategy based on total system energy use is shown to be able to save up to 11% of energy under certain conditions and to be most useful for dry climates

    Saving Building Energy through Advanced Control Strategies

    No full text
    This article presents an analysis of the relationship between building energy usage and building control system operation and performance. A method is presented for estimating the energy saving potential of improvements in building and control system operation, including the relative impact of recommssioning and hardware and software upgrades, based on a subjective assessment of the level of energy efficient design and the energy usage of the building relative to similar buildings as indicated by the Energy Utilization Index for the building. The method introduces a Building Design Index and a Building Operating Index to evaluate building energy performance versus similar buildings, and uses these indices to estimate potential savings and effectiveness of control system improvements