184 research outputs found

    Thrombolytic therapy, infarct vessel patency and late potentials: Can the arrhythmic substrate be altered?

    Get PDF

    Role of signal averaging of the surface QRS complex in selecting patients with nonsustained ventricular tachycardia and high grade ventricular arrhythmias for programmed ventricular stimulation

    Get PDF
    Signal averaging of the surface QRS complex was performed before programmed ventricular stimulation in 53 individuals with high grade ventricular arrhythmias or nonsustained ventricular tachycardia, or both. An abnormal signal-averaged electrocardiogram (ECG) was recorded in 22 patients and was associated with inducible ventricular tachycardia in 12 (55%) of the 22. In contrast, a normal signal-averaged ECG was associated with inducible tachycardia in only 1 (3%) of 31 individuals (p < 0.005). The group with inducible tachycardia had a longer duration of the signal-averaged QRS complex (124 ± 19 versus 96 ± 26 ms) and of low amplitude signals (44 ± 13 versus 29 ± 11 ms) (p < 0.005). In addition, the root mean square voltage of the terminal 40 ms was lower in this group (20 ± 14 versus 48 ± 34 µV, p < 0.005).Twenty-seven of the 53 subjects had a prior myocardial infarction; 17 (63%) of the 27 had an abnormal signalaveraged ECG, and ventricular tachycardia was inducible in 10 (59%) of the 17. A normal signal-averaged ECG was recorded in 10 of the 27 patients and only 1 (10%) of these 10 had inducible tachycardia. An abnormal signal-averaged ECG had a 91% sensitivity and a 56% specificity with respect to subsequent induction of tachycardia.During long-term follow-up, 2 (15%) of the 13 patients with inducible ventricular tachycardia who were treated with eleetrophysiologically guided antiarrhythmics therapy died suddenly; the remaining 11 patients (85%) are alive 15 ± 10 months after electrophysiologic testing. Both of these patients who died had an abnormal signal-averaged ECG. In contrast, only 2 (5%) of the 40 patients with no inducible tachycardia, both with a normal signal-averaged ECG, have had an arrhythmic event; the other 38 patients have remained free of sustained ventricular arrhythmia for a follow-up period of 17 ± 9 months.In conclusion: 1) Signal averaging of the surface QRS complex is useful in identifying patients with nonsustained ventricular tachycardia or high grade ventricular arrhythmias, or both, who will have inducible ventricular tachycardia on programmed ventricular stimulation. 2) Inducibility of arrhythmia is unlikely in individuals who have a normal signal-averaged ECG despite the presence of complex ventricular arrhythmia. 3) The occurrence of spontaneous sustained ventricular tachyarrhythmias is low in patients with a prior myocardial infarction and without inducible ventricular tachycardia who have nonsustained ventricular tachycardia or complex ventricular arrhythmias and a normal signal-averaged ECG. 4) Signalaveraged electrocardiography may be useful in detecting low risk groups of patients with complex ventricular arrhythmias who do not require electrophysiologic testing or antiarrhythmic therapy

    The role of silent ischemia, the arrhythmic substrate and the short-long sequence in the genesis of sudden cardiac death

    Get PDF
    AbstractTo study the role of silent ischemia and the arrhythmic substrate in the genesis of sudden cardiac death, 67 patients were studied (mean age 62 ± 12 years). Of these, 14 patients (Group 1) had an in-hospital episode of ventricular tachycardia or fibrillation while wearing a 24 h Holter ambulatory electrocardiographic (ECG) monitor, 33 (Group II) had a documented episode of sustained ventricular tachycardia or fibrillation, or both, and 20 (Group III) had angina pectoris but no ventricular tachycardia or fibrillation. Eight Group I survivors underwent programmed electrical stimulation or ECG signal averaging, or both. All Group II patients underwent 24 h Holter monitoring and ECG signal averaging to detect late potentials before programmed electrical stimulation. Group III patients underwent both 24 h Holter recording and coronary angiography. The 24 h ECG tapes were analyzed for ST segment changes, prematurity index and characteristics of ventricular premature depolarizations. Any ST depression ≥1mm for >30 s was considered to be a reflection of silent ischemia, and the induction of ventricular tachycardia or fibrillation by programmed electrical stimulation or the presence of late potentials, or both, was considered to be a reflection of the arrhythmia substrate.Silent ischemia preceded ventricular tachycardia in only 2 (14%) of the 14 Group I patients. The prematurity index was <1 in only 18% of ventricular tachycardia episodes. However, 14 (64%) of 22 episodes of ventricular tachycardia in 9 (64%) of the 14 patients were initiated by a ventricular premature depolarization preceded by a short-long sequence (sinus beat-ventricular premature depolarization-sinus beat) with a ratio of 0.5 ± 0.1. Six (75%) of eight in-hospital survivors of ventricular tachycardia or fibrillation (Group 1) had an arrhythmic substrate. A significantly (p < 0.0001) higher percent of the 33 Group II patients had an arrhythmic substrate (93%) than had silent ischemic episodes (45%). Silent ischemia resulted in ventricular tachycardia in only 1(7%) of 15 Group II patients. There was no significant difference between the incidence of silent ischemia (45% versus 35%) and the extent of coronary artery disease between Groups II and III.It is concluded that: 1) Silent ischemia was not a major determinant of ventricular tachycardia. 2) Although silent ischemia was common in survivors of ventricular tachycardia or fibrillation, its incidence was not significantly different from that in patients with angina pectoris and no sustained ventricular arrhythmias. 3) A high percent of patients (75% to 93%) with ventricular tachycardia and fibrillation have an arrhythmic substrate. 4) In the absence of acute myocardial infarction, sudden cardiac death is frequently triggered by a ventricular premature depolarization, with a preceding short-long cycle that likely produces dispersion of refractoriness in the arrhythmic substrate

    Duration learning for analysis of nanopore ionic current blockades

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ionic current blockade signal processing, for use in nanopore detection, offers a promising new way to analyze single molecule properties, with potential implications for DNA sequencing. The alpha-Hemolysin transmembrane channel interacts with a translocating molecule in a nontrivial way, frequently evidenced by a complex ionic flow blockade pattern. Typically, recorded current blockade signals have several levels of blockade, with various durations, all obeying a fixed statistical profile for a given molecule. Hidden Markov Model (HMM) based duration learning experiments on artificial two-level Gaussian blockade signals helped us to identify proper modeling framework. We then apply our framework to the real multi-level DNA hairpin blockade signal.</p> <p>Results</p> <p>The identified upper level blockade state is observed with durations that are geometrically distributed (consistent with an a physical decay process for remaining in any given state). We show that mixture of convolution chains of geometrically distributed states is better for presenting multimodal long-tailed duration phenomena. Based on learned HMM profiles we are able to classify 9 base-pair DNA hairpins with accuracy up to 99.5% on signals from same-day experiments.</p> <p>Conclusion</p> <p>We have demonstrated several implementations for <it>de novo </it>estimation of duration distribution probability density function with HMM framework and applied our model topology to the real data. The proposed design could be handy in molecular analysis based on nanopore current blockade signal.</p

    SVM clustering

    Get PDF

    The NTD Nanoscope: potential applications and implementations

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Nanopore transduction detection (NTD) offers prospects for a number of highly sensitive and discriminative applications, including: (i) single nucleotide polymorphism (SNP) detection; (ii) targeted DNA re-sequencing; (iii) protein isoform assaying; and (iv) biosensing via antibody or aptamer coupled molecules. Nanopore event transduction involves single-molecule biophysics, engineered information flows, and nanopore cheminformatics. The NTD Nanoscope has seen limited use in the scientific community, however, due to lack of information about potential applications, and lack of availability for the device itself. Meta Logos Inc. is developing both pre-packaged device platforms and component-level (unassembled) kit platforms (the latter described here). In both cases a lipid bi-layer workstation is first established, then augmentations and operational protocols are provided to have a nanopore transduction detector. In this paper we provide an overview of the NTD Nanoscope applications and implementations. The NTD Nanoscope Kit, in particular, is a component-level reproduction of the standard NTD device used in previous research papers.</p> <p>Results</p> <p>The NTD Nanoscope method is shown to functionalize a single nanopore with a channel current modulator that is designed to transduce events, such as binding to a specific target. To expedite set-up in new lab settings, the calibration and troubleshooting for the NTD Nanoscope kit components and signal processing software, the NTD Nanoscope Kit, is designed to include a set of test buffers and control molecules based on experiments described in previous NTD papers (the model systems briefly described in what follows). The description of the Server-interfacing for advanced signal processing support is also briefly mentioned.</p> <p>Conclusions</p> <p>SNP assaying, SNP discovery, DNA sequencing and RNA-seq methods are typically limited by the accuracy of the error rate of the enzymes involved, such as methods involving the polymerase chain reaction (PCR) enzyme. The NTD Nanoscope offers a means to obtain higher accuracy as it is a single-molecule method that does not inherently involve use of enzymes, using a functionalized nanopore instead.</p

    DNA Molecule Classification Using Feature Primitives

    Get PDF
    BACKGROUND: We present a novel strategy for classification of DNA molecules using measurements from an alpha-Hemolysin channel detector. The proposed approach provides excellent classification performance for five different DNA hairpins that differ in only one base-pair. For multi-class DNA classification problems, practitioners usually adopt approaches that use decision trees consisting of binary classifiers. Finding the best tree topology requires exploring all possible tree topologies and is computationally prohibitive. We propose a computational framework based on feature primitives that eliminates the need of a decision tree of binary classifiers. In the first phase, we generate a pool of weak features from nanopore blockade current measurements by using HMM analysis, principal component analysis and various wavelet filters. In the next phase, feature selection is performed using AdaBoost. AdaBoost provides an ensemble of weak learners of various types learned from feature primitives. RESULTS AND CONCLUSION: We show that our technique, despite its inherent simplicity, provides a performance comparable to recent multi-class DNA molecule classification results. Unlike the approach presented by Winters-Hilt et al., where weaker data is dropped to obtain better classification, the proposed approach provides comparable classification accuracy without any need for rejection of weak data. A weakness of this approach, on the other hand, is the very "hands-on" tuning and feature selection that is required to obtain good generalization. Simply put, this method obtains a more informed set of features and provides better results for that reason. The strength of this approach appears to be in its ability to identify strong features, an area where further results are actively being sought
    • …
    corecore