972 research outputs found

    Henry Ford Hospital: Options and Opportunities in the 1980s

    Get PDF
    This presentation by Mr. Peters and Dr. Steinhauer was given before the Henry Ford Hospital Professional Staff at a semi-annual dinner and staff meeting held on Tuesday, May 6, 1980. It offers a timely assessment of the position and prospects of the Hospital as we enter the new decade. On occasion, the journal features nontechnical articles like this presentation that we believe are of general interest to our readers

    WIYN/Hydra Detection of Lithium Depletion in F Stars of the Young Open Cluster M35 and Implications for the Development of the Lithium Gap

    Full text link
    We report discovery of significant depletion of Li on the surfaces of F dwarf stars in the 150-Myr-old open cluster M35, analagous to a feature in the 700-Myr-old Hyades cluster that has been referred to as the ``Li gap.'' We have caught the gap in the act of forming: using high resolution, high S/N, WIYN/Hydra observations, we detect Li in all but a few M35 F stars; the maximum depletion lies at least 0.6-0.8 dex below minimally depleted (or undepleted) stars. The M35 Li depletion region, a) is quite wide, with clear depletion seen from 6000K to 6700K or hotter; b) shows a significant dispersion in Li abundance at all T_eff, even with stars of the same T_eff; and c) contains undepleted stars (as well as depleted ones) in the (narrow) classical Hyades gap region, which itself shows no undepleted stars. All of these M35 Li depletion properties support rotationally-induced slow mixing as the primary physical mechanism that forms the gap, and argues against other proposed mechanisms, particularly diffusion and steady main sequence mass loss. When viewed in the context of the M35 Li depletion properties, the Hyades Li gap may well be wider than is usually recognized.Comment: 14 Pages, 3 figures. Accepted to ApJ Letter

    Near-Field Scanning Microwave Microscopy: Measuring Local Microwave Properties and Electric Field Distributions

    Full text link
    We describe the near-field microwave microscopy of microwave devices on a length scale much smaller than the wavelength used for imaging. Our microscope can be operated in two possible configurations, allowing a quantitative study of either material properties or local electric fields.Comment: 4 pages, 8 figures, minor corrections to text and 2 figure

    Frequency Following Imaging of Electric Fields from Resonant Superconducting Devices using a Scanning Near-Field Microwave Microscope

    Full text link
    We have developed a scanning near-field microwave microscope that operates at cryogenic temperatures. Our system uses an open-ended coaxial probe with a 200 mm inner conductor diameter and operates from 77 to 300 K in the 0.01-20 GHz frequency range. In this paper, we present microwave images of the electric field distribution above a Tl2Ba2CaCu2O8 microstrip resonator at 77 K, measured at several heights. In addition, we describe the use of a frequency-following circuit to study the influence of the probe on the resonant frequency of the device.Comment: 4 pages, postscript file with 6 figures conference proceeding for the Applied Superconductivity Conference 199

    Low Power Superconducting Microwave Applications and Microwave Microscopy

    Get PDF
    We briefly review some non-accelerator high-frequency applications of superconductors. These include the use of high-Tc superconductors in front-end band-pass filters in cellular telephone base stations, the High Temperature Superconductor Space Experiment, and high-speed digital electronics. We also present an overview of our work on a novel form of near-field scanning microscopy at microwave frequencies. This form of microscopy can be used to investigate the microwave properties of metals and dielectrics on length scales as small as 1 mm. With this microscope we have demonstrated quantitative imaging of sheet resistance and topography at microwave frequencies. An examination of the local microwave response of the surface of a heat-treated bulk Nb sample is also presented.Comment: 11 pages, including 6 figures. Presented at the Eight Workshop on RF Superconductivity. To appear in Particle Accelerator

    Imaging Microwave Electric Fields Using a Near-Field Scanning Microwave Microscope

    Full text link
    By scanning a fine open-ended coaxial probe above an operating microwave device, we image local electric fields generated by the device at microwave frequencies. The probe is sensitive to the electric flux normal to the face of its center conductor, allowing different components of the field to be imaged by orienting the probe appropriately. Using a simple model of the microscope, we are able to interpret the system's output and determine the magnitude of the electric field at the probe tip. We show images of electric field components above a copper microstrip transmission line driven at 8 GHz, with a spatial resolution of approximately 200 ÎĽ\mum.Comment: 10 pages, 3 eps-figures, accepted by Appl. Phys. Let
    • …
    corecore