1,882 research outputs found

    Patient initiated clinics for patients with chronic or recurrent conditions managed in secondary care: a systematic review of patient reported outcomes and patient and clinician satisfaction

    Get PDF
    This is the final version of the article. Available from BioMed Central via the DOI in this record.BACKGROUND: The cost to the NHS of missed or inappropriate hospital appointments is considerable. Alternative methods of appointment scheduling might be more flexible to patients' needs without jeopardising health and service quality. The objective was to systematically review evidence of patient initiated clinics in secondary care on patient reported outcomes among patients with chronic/recurrent conditions. METHODS: Seven databases were searched from inception to June 2013. Hand searching of included studies references was also conducted. Studies comparing the effects of patient initiated clinics with traditional consultant led clinics in secondary care for patients with long term chronic or recurrent diseases on health related quality of life and/or patient satisfaction were included. Data was extracted by one reviewer and checked by a second. Results were synthesised narratively. RESULTS: Seven studies were included in the review, these covered a total of 1,655 participants across three conditions: breast cancer, inflammatory bowel disease and rheumatoid arthritis. Quality of reporting was variable. Results showed no significant differences between the intervention and control groups for psychological and health related quality of life outcomes indicating no evidence of harm. Some patients reported significantly more satisfaction using patient-initiated clinics than usual care (p < 0.001). CONCLUSIONS: The results show potential for patient initiated clinics to result in greater patient and clinician satisfaction. The patient-consultant relationship appeared to play an important part in patient satisfaction and should be considered an important area of future research as should the presence or absence of a guidebook to aid self-management. Patient initiated clinics fit the models of care suggested by policy makers and so further research into long term outcomes for patients and service use in this area of practice is both relevant and timely.This systematic review was funded by the National Institute of Health Research (NIHR) Collaboration for Leadership in Applied Health Research and Care (CLAHRC) for the South West. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the NIHR or the Department of Health

    Neurofilament light chain in the vitreous humor of the eye

    Get PDF
    Background: Neurofilament light chain (NfL) is a promising biomarker of neurodegeneration in the cerebrospinal fluid and blood. This study investigated the presence of NfL in the vitreous humor and its associations with amyloid beta, tau, inflammatory cytokines and vascular proteins, apolipoprotein E (APOE) genotypes, Mini-Mental State Examination (MMSE) scores, systemic disease, and ophthalmic diseases. / Methods: This is a single-site, prospective, cross-sectional cohort study. Undiluted vitreous fluid (0.5–1.0 mL) was aspirated during vitrectomy, and whole blood was drawn for APOE genotyping. NfL, amyloid beta (Aβ), total Tau (t-Tau), phosphorylated Tau (p-Tau181), inflammatory cytokines, chemokines, and vascular proteins in the vitreous were quantitatively measured by immunoassay. The main outcome measures were the detection of NfL levels in the vitreous humor and its associations with the aforementioned proteins. Linear regression was used to test the associations of NfL with other proteins, APOE genotypes, MMSE scores, and ophthalmic and systemic diseases after adjustment for age, sex, education level, and other eye diseases. / Results: NfL was detected in all 77 vitreous samples. NfL was not found to be associated with ophthalmic conditions, APOE genotypes, MMSE scores, or systemic disease (p > 0.05). NfL levels were positively associated with increased vitreous levels of Aβ40 (p = 7.7 × 10−5), Aβ42 (p = 2.8 × 10−4), and t-tau (p = 5.5 × 10−7), but not with p-tau181 (p = 0.53). NfL also had significant associations with inflammatory cytokines such as interleukin-15 (IL-15, p = 5.3 × 10−4), IL-16 (p = 2.2 × 10−4), monocyte chemoattractant protein-1 (MCP1, p = 4.1 × 10−4), and vascular proteins such as vascular endothelial growth factor receptor-1 (VEGFR1, p = 2.9 × 10−6), Vegf-C (p = 8.6 × 10−6), vascular cell adhesion molecule-1 (VCAM-1, p = 5.0 × 10−4), Tie-2 (p = 6.3 × 10−4), and intracellular adhesion molecular-1 (ICAM-1, p = 1.6 × 10−4). / Conclusion: NfL is detectable in the vitreous humor of the eye and significantly associated with amyloid beta, t-tau, and select inflammatory and vascular proteins in the vitreous. Additionally, NfL was not associated with patients’ clinical eye condition. Our results serve as a foundation for further investigation of NfL in the ocular fluids to inform us about the potential utility of its presence in the eye

    Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation

    Get PDF
    BACKGROUND: Expanded polytetrafluroethelyne (e PTFE, Gore-Tex(®)) has been advocated as an implant material for medialization of the vocal fold. Animal studies involving rabbits and a porcine model have demonstrated host tolerance of the implant. There have been no reports describing the histological changes in a human laryngectomy specimen with a Gore-Tex implant. CASE PRESENTATION: The histological findings in a laryngectomy specimen of a patient previously implanted with e PTFE for medialization of a paralyzed vocal fold following excision of a vagal neurofibroma were studied. Histopathology revealed a mild foreign-body giant cell granulomatous reaction with some associated fibrosis. The granulomatous response was limited to the periphery of the Gore-Tex and although it closely followed the profile of the material it did not encroach into or significantly break up the material. There was no significant neutrophilic or lymphocytic inflammation. CONCLUSIONS: Our findings are consistent with the animal models confirming that Gore-Tex implantation does not result in a significant granulomatous reaction in the human larynx over a 13-month period. Moreover, there is no evidence of resorption or infection. Further, the lack of lymphocytes in association with the granulomas indicates that there is no significant immunological hypersensitivity. Histologically, the slight permeation by connective tissue is similar to that seen in Gore-Tex vascular and cardiac implants. The degree of the slight giant cell response appears to be dependent on the profile of the material; a sharp edge incited more of a response than a flat surface

    Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial

    Get PDF
    BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379

    International Veterinary Epilepsy Task Force Consensus Proposal: Outcome of therapeutic interventions in canine and feline epilepsy

    Get PDF
    Common criteria for the diagnosis of drug resistance and the assessment of outcome are needed urgently as a prerequisite for standardized evaluation and reporting of individual therapeutic responses in canine epilepsy. Thus, we provide a proposal for the definition of drug resistance and partial therapeutic success in canine patients with epilepsy. This consensus statement also suggests a list of factors and aspects of outcome, which should be considered in addition to the impact on seizures. Moreover, these expert recommendations discuss criteria which determine the validity and informative value of a therapeutic trial in an individual patient and also suggest the application of individual outcome criteria. Agreement on common guidelines does not only render a basis for future optimization of individual patient management, but is also a presupposition for the design and implementation of clinical studies with highly standardized inclusion and exclusion criteria. Respective standardization will improve the comparability of findings from different studies and renders an improved basis for multicenter studies. Therefore, this proposal provides an in-depth discussion of the implications of outcome criteria for clinical studies. In particular ethical aspects and the different options for study design and application of individual patient-centered outcome criteria are considered

    Inhaled ciclesonide versus inhaled budesonide or inhaled beclomethasone or inhaled fluticasone for chronic asthma in adults: a systematic review

    Get PDF
    BACKGROUND: Ciclesonide is a new inhaled corticosteroids licensed for the prophylactic treatment of persistent asthma in adults. Currently beclomethasone dipropionate, budesonide and fluticasone propionate are the most commonly prescribed inhaled corticosteroids for the treatment of asthma but there has been no systematic review comparing the effectiveness and safety ciclesonide to these agents. We therefore aimed to systematically review published randomised controlled trials of the effectiveness and safety of ciclesonide compared to alternative inhaled corticosteroids in people with asthma. METHODS: We performed literature searches on MEDLINE, EMBASE, PUBMED, the COCHRANE LIBRARY and various Internet evidence sources for randomised controlled trials or systematic reviews comparing ciclesonide to beclomethasone or budesonide or fluticasone in adult humans with persistent asthma. Data was extracted by one reviewer. RESULTS: Five studies met the inclusion criteria. Methodological quality was variable. There were no trials comparing ciclesonide to beclomethasone. There was no significant difference between ciclesonide and budesonide or fluticasone on the following outcomes: lung function, symptoms, quality of life, airway responsiveness to a provoking agent or inflammatory markers. However, the trials were very small in size, increasing the possibility of a type II error. One trial demonstrated that the combined deposition of ciclesonide (and its active metabolite) in the oropharynx was 47% of that of budesonide while another trial demonstrated that the combined deposition of ciclesonide (and its active metabolite) in the oropharynx was 53% of that of fluticasone. One trial demonstrated less suppression of cortisol in overnight urine collection after ciclesonide compared to fluticasone (geometric mean fold difference = 1.5, P < 0.05) but no significant difference in plasma cortisol response. CONCLUSION: There is very little evidence comparing CIC to other ICS, restricted to very small, phase II studies of low power. These demonstrate CIC has similar effectiveness and efficacy to FP and BUD (though equivalence is not certain) and findings regarding oral deposition and HPA suppression are inconclusive. There is no direct comparative evidence that CIC causes fewer side effects since none of the studies reported patient-based outcomes

    Developments in esophageal surgery for adenocarcinoma: a comparison of two decades

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objective of this study was to examine outcomes in patients undergoing esophageal resection for adenocarcinoma at our institution during a 20-year period and, in particular, to address temporal trends in long-term survival.</p> <p>Methods</p> <p>Out of 470 patients who underwent esophagectomy for malignancy between September 1985 and September 2005, a total number of 175 patients presented with esophageal adenocarcinoma. Patients enrolled in this study included AEG (adenocarcinoma of the esophagogastric junction) type I tumors only. Time trends were studied comparing two decades, 9/1985 to 9/1995 (DI) and 10/1995 to 9/2005 (DII).</p> <p>Results</p> <p>The overall survival was significantly more favourable in patients undergoing esophageal resection for adenocarcinoma in the recent time period (DII, 10/1995 to 9/2005) as compared to the early time period (DI, 9/1985 to 9/1995) (log rank test: p = 0.0329). Significant differences in the recent decade were seen based on lower ASA-classifications, earlier tumor stages, and the operative procedure with a higher frequency of transhiatal resections (p < 0.05). 30-day mortality improved from 8.3% to 3.1% during the 20-year time-interval, thus without statistical significance.</p> <p>Conclusion</p> <p>Based on our experience, overall survival is improving over time for adenocarcinoma of the esophagus. Factors that may play an important role in this trend include early diagnosis and improved patient selection through better preoperative staging, improved surgical technique with a tailored approach carefully evaluated by physiologic patient status, comorbidity and tumor extent.</p

    An iterative block-shifting approach to retention time alignment that preserves the shape and area of gas chromatography-mass spectrometry peaks

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Metabolomics, petroleum and biodiesel chemistry, biomarker discovery, and other fields which rely on high-resolution profiling of complex chemical mixtures generate datasets which contain millions of detector intensity readings, each uniquely addressed along dimensions of <it>time </it>(<it>e.g.</it>, <it>retention time </it>of chemicals on a chromatographic column), a <it>spectral value </it>(<it>e.g., mass-to-charge ratio </it>of ions derived from chemicals), and the <it>analytical run number</it>. They also must rely on data preprocessing techniques. In particular, inter-run variance in the retention time of chemical species poses a significant hurdle that must be cleared before feature extraction, data reduction, and knowledge discovery can ensue. <it>Alignment methods</it>, for calibrating retention reportedly (and in our experience) can misalign matching chemicals, falsely align distinct ones, be unduly sensitive to chosen values of input parameters, and result in distortions of peak shape and area.</p> <p>Results</p> <p>We present an iterative block-shifting approach for retention-time calibration that detects chromatographic features and qualifies them by retention time, spectrum, and the effect of their inclusion on the quality of alignment itself. Mass chromatograms are aligned pairwise to one selected as a reference. In tests using a 45-run GC-MS experiment, block-shifting reduced the absolute deviation of retention by greater than 30-fold. It compared favourably to COW and XCMS with respect to alignment, and was markedly superior in preservation of peak area.</p> <p>Conclusion</p> <p>Iterative block-shifting is an attractive method to align GC-MS mass chromatograms that is also generalizable to other two-dimensional techniques such as HPLC-MS.</p
    • …
    corecore