18 research outputs found

    Tritiation of amorphous and crystalline silicon using T <inf>2</inf> gas

    Get PDF
    Incorporation of tritium in hydrogenated amorphous silicon (a-Si:H) and crystalline silicon (c-Si) at 250 °C using tritium (T 2) gas at pressures of up to 120 atm is reported. The tritium is stored in a surface layer which is approximately 150 and 10 nm for a-Si:H and c-Si, respectively. The concentration of tritium occluded in planar and textured c-Si is linearly dependent on the total surface area. The tritium is stable and the dominant tritium evolution occurs at temperatures above 300 °C. The concentration of tritium locked in a-Si:H and c-Si was 20 and 4 at. %, respectively. Self-catalysis appears to be important in the tritiation process. © 2006 American Institute of Physics

    Power-scaling performance of a three-dimensional tritium betavoltaic diode

    Get PDF
    Three-dimensional diodes fabricated by electrochemical etching are exposed to tritium gas at pressures from 0.05 to 33 atm at room temperature to examine its power scaling performance. It is shown that the three-dimensional microporous structure overcomes the self-absorption limited saturation of beta flux at high tritium pressures. These results are contrasted against the three-dimensional device powered in one instance by tritium absorbed in the near surface region of the three-dimensional microporous network, and in another by a planar scandium tritide foil. These findings suggest that direct tritium occlusion in the near surface of three-dimensional diode can improve the specific power production. © 2009 American Institute of Physics

    Tritium locked in silica using 248 nm KrF laser irradiation

    Get PDF
    In this Letter we report on selectively occluding tritium in a silica film on a silicon substrate using a combination of high-pressure tritium loading and 248 nm KrF laser irradiation. Sixty percent of tritium dissolved in the silica film was bonded by laser irradiation. The concentration of the bonded tritium was proportional to the total laser fluence. Tritium effusion experiments indicated that the laser-locked tritium existed stably in the glass matrix up to 400 °C. In this work we point a way to a safe and simple approach for the integration of on-chip radioisotope micropower sources for micromechanical and microelectronic applications. © 2006 American Institute of Physics

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Failure of Al ‐ SiO2 ‐ Si MOS Capacitors at High Temperatures

    No full text
    corecore