23 research outputs found

    Computed Tomography Coronary Angiography to Triage Patients With Chest Pain: The CT-STAT Trial

    Get PDF
    Coronary computed tomography angiography (CCTA) is a non-invasive alternative to invasive coronary angiography, which is highly reliable to rule out obstructive coronary artery disease. It has also been proposed and used for the assessment of patients with acute chest pain in the emergency department setting. Recently the results of a multicenter randomized trial, the CT-STAT (Coronary Computed Tomographic Angiography for Systematic Triage of Acute Chest Pain Patients to Treatment) trial have been published. In the present article the main messages of this important study will be presented and discussed

    Restenosis is not associated with stent length in a pig model of coronary stent implantation

    Get PDF
    Background: The aim of this study was to determine if stent length is by itself a risk factor for intimal proliferation and restenosis. Long lesions represent an independent risk factor for restenosis after coronary stent implantation. A longer stented segment might result in a higher probability of restenosis. Methods: Twenty-two 7-month-old male farm pigs underwent implantation of two steel stents, one short (8 mm length) and one long (16 mm length), in the right coronary artery. The pigs were sacrificed 28 days after stent implantation and histomorphometric analysis of the coronary arteries was performed for neointimal area proliferation and area stenosis evaluation. Results: Seventeen short stents and 19 long stents were finally implanted. There were no differences in neointimal proliferation (1.84 ± 0.64 mm2 vs. 1.81 ± 0.94 mm2, p = 0.84), area stenosis (40 ± 9% vs. 41 ± 19%, p = 0.86) and lumen area (2.96 ± 1.30 mm2 vs. 2.51 ± ± 1.18 mm2, p = 0.21) between the short stent group and the long stent group, respectively. Conclusions: These data suggest that stent length by itself does not influence restenosis extent in the porcine model

    Left Ventricular Mass One Year After Radiofrequency Ablation for Atrial Fibrillation

    Get PDF
    Myxomas are the most common benign tumors of the heart. The exact etiology of myxomas is unknown and most cases are sporadic. It is well known though that myxomas can develop after cardiac trauma, and that radiofrequency ablation (RFA) for paroxysmal atrial fibrillation (PAF) increases the risk of thrombus or endocarditis in the atrium. The association of RFA and the formation of myxomas is not known. We report a case of a left ventricular myxoma in a patient after RFA

    Characteristics, Perceived Side Effects and Benefits of Electronic Cigarette Use: A Worldwide Survey of More than 19,000 Consumers

    No full text
    Background: Electronic cigarette (EC) use has grown exponentially over the past few years. The purpose of this survey was to assess the characteristics and experiences of a large sample of EC users and examine the differences between those who partially and completely substituted smoking with EC use. Methods: A questionnaire was prepared, translated into 10 different languages and uploaded in an online survey tool. EC users were asked to participate irrespective of their current smoking status. Participants were divided according to their smoking status at the time of participation in two subgroups: former smokers and current smokers. Results: In total, 19,414 participants were included in the analysis, with 88 of them (0.5%) reported not being smokers at the time of EC use initiation. Complete substitution of smoking was reported by 81.0% of participants (former smokers) while current smokers had reduced smoking consumption from 20 to 4 cigarettes per day. They were using ECs for a median of 10 months. They initiated EC use with a median of 18 mg/mL nicotine-concentration liquids; 21.5% used higher than 20 mg/mL. Only 3.5% of participants were using 0-nicotine liquids at the time of the survey. Former smokers were highly dependent (Fagerström Test for Cigarette Dependence = 7) and were heavier smokers (21 cigarettes per day when smoking) compared to current smokers. The most important reasons for initiating EC use for both subgroups was to reduce the harm associated with smoking and to reduce exposure of family members to second-hand smoking. Most considered ECs as less harmful than tobacco cigarettes, while 11.0% considered them absolutely harmless. Side effects were reported by more than half of the participants (59.8%), with the most common being sore/dry mouth and throat; side effects were mild and in most cases were subsequently resolved (partially or completely). Participants experienced significant benefits in physical status and improvements in pre-existing disease conditions (including respiratory disease such as asthma and chronic obstructive lung disease). Being former smoker was independently associated with positive effects in health and improvements in disease conditions. Conclusions: The results of this worldwide survey of dedicated users indicate that ECs are mostly used to avoid the harm associated with smoking. They can be effective even in highly-dependent smokers and are used as long-term substitutes for smoking. High levels of nicotine are used at initiation; subsequently, users try to reduce nicotine consumption, with only a small minority using non-nicotine liquids. Side effects are minor and health benefits are substantial, especially for those who completely substitute smoking with EC use. Further population and interventional studies are warranted

    Evaluating Nicotine Levels Selection and Patterns of Electronic Cigarette use in a Group of “Vapers” Who Had Achieved Complete Substitution of Smoking

    Get PDF
    Background Electronic cigarettes (ECs) are alternative-to-smoking nicotine delivery devices; consumers (commonly called vapers) use them in order to reduce or completely substitute smoking. The European Commission has released a proposal for a new Tobacco Product Directive that might reduce availability of nicotine-containing products, including ECs. In this study, the EC use patterns in subjects who have completely substituted smoking with EC use were examined by personal interviews. The study focused on nicotine levels used in order to achieve smoking cessation, reported benefits, associated side effects, and estimation of EC dependence compared with smoking. Methods Participants were 111 subjects who had completely substituted smoking with EC use for at least 1 month. Smoking abstinence was validated by measuring blood carboxyhemoglobin levels. Nicotine levels at initiation of EC use, at time of smoking cessation, and at time of interview were recorded. Dependence potential was assessed by asking the first question of the Fagerström Test for Cigarette Dependence (time until smoking the first cigarette and until first use of EC in the morning) and questions about perceived past dependence on tobacco cigarettes and present dependence on EC. Results Forty-two percent of participants reported quitting smoking during the first month of EC use. Liquids with nicotine concentration >15 mg/mL were used by 74% of users at initiation of EC use, while 16.2% had to increase the initial nicotine levels in order to achieve complete smoking abstinence. Seventy-two participants (64.9%) reported that from the time of smoking cessation to the time of the interview (8 months median duration of EC use) they reduced the nicotine concentration they were consuming; however, only 12% of the total sample was using ≤5 mg/mL nicotine concentration at the time of the interview. Side effects were mild and temporary. The vast majority of participants reported better exercise capacity and improved olfactory and gustatory senses. Perceived EC dependenct was significantly lower compared to smoking. Conclusions Nicotine levels appear to play an important role in achieving and maintaining smoking cessation in the group of motivated subjects studied. High nicotine-containing liquids were used while few mild and temporary side effects were reported. Proposals about regulation should consider the pragmatic use patterns of ECs, especially in consumers who have completely substituted smoking

    www.mdpi.com/journal/ijerph Evaluation of Electronic Cigarette Use (Vaping) Topography and Estimation of Liquid Consumption: Implications for Research Protocol Standards Definition and for Public Health Authorities ’ Regulation

    Get PDF
    Abstract: Background: Although millions of people are using electronic cigarettes (ECs) and research on this topic has intensified in recent years, the pattern of EC use has not been systematically studied. Additionally, no comparative measure of exposure and nicotine delivery between EC and tobacco cigarette or nicotine replacement therapy (NRTs) has been established. This is important, especially in the context of the proposal for a new Tobacco Product Directive issued by the European Commission. Methods: A second generation EC device, consisting of a higher capacity battery and tank atomiser design compared to smaller cigarette-like batteries and cartomizers, and a 9 mg/mL nicotine-concentration liquid were used in this study. Eighty subjects were recruited; 45 experienced EC users and 35 smokers. EC users were video-recorded when using the device (ECIG group), while smokers were recorded when smoking (SM-S group) and when using the EC (SM-E group) in a randomized cross-over design. Puff, inhalation and exhalation duration were measured. Additionally, the amount of EC liquid consumed by experienced EC users was measured at 5 min (similar to the time needed to smoke one tobacco cigarette) and at 20 min (similar to the time needed for a nicotine inhaler to deliver 4 mg nicotine). Results: Puff duration wasInt. J. Environ. Res. Public Health 2013, 10 250
    corecore