    Sources d'exposition aux phtalates dans une unité de soins néonatals [Phthalate exposure in the neonatal intensive care unit].

    No full text
    There are growing concerns on long-term health consequences, notably on fertility rates, of plasticizers such as phthalates. While di(2-ethylhexyl)phthalate (DEHP) is currently used in several medical devices, newborns in the neonatal intensive care unit are both more exposed and more vulnerable to DEHP. The objectives of this study were to identify, count, and describe possible sources of DEHP in a neonatal care unit. Our method consisted in the listing and the inspection of the information on packaging, complemented by contact with manufacturers when necessary. According to the results, 6% of all products and 10% of plastic products contained some DEHP; 71% of these involved respiratory support devices. A vast majority of the items showed no information on the content of DEHP. Further research is needed, particularly to determine the effects of such an early exposure and to study and develop safer alternatives

    Nasal trauma due to continuous positive airway pressure in neonates.

    No full text
    PATIENTS: All neonates admitted between January 2002 and December 2007 treated by nCPAP were eligible. METHODS: Patients' noses were monitored during nCPAP. Nasal trauma was reported into three stages: (I) persistent erythema; (II) superficial ulceration; and (III) necrosis. RESULTS: 989 neonates were enrolled. Mean gestational age was 34 weeks (SD 4), mean birth weight 2142 g (SD 840). Nasal trauma was reported in 420 (42.5%) patients and it was of stage I, II and III in 371 (88.3%), 46 (11%) and 3 (0.7%) patients, respectively. Incidence and severity of trauma were inversely correlated with gestational age and birth weight. The risk of nasal trauma was greater in neonates <32 weeks of gestational age (OR 2.48, 95% CI 1.59 to 3.86), weighing <1500 g at birth (OR 2.28, 95% CI 1.43 to 3.64), treated >5 days by nCPAP (OR 5.36, 95% CI 3.82 to 7.52), or staying >14 days in the NICU (OR 1.67, 95% CI 1.22 to 2.28). Most cases of nasal trauma (90%) appeared during the first 6 days of nCPAP. Persistent visible scars were present in two cases. CONCLUSIONS: Nasal trauma is a frequent complication of nCPAP, especially in preterm neonates, but long-term cosmetic sequelae are very rare. This study provides a description of nasal trauma and proposes a simple staging system. This could serve as a basis to develop strategies of prevention and treatment of this iatrogenic event

    Evaluation of different POCT devices for glucose measurement in a clinical neonatal setting.

    Get PDF
    Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance
    corecore