6 research outputs found

    Wp艂yw pulsacyjnego pola elektrycznego na prze偶ywalno艣膰 Yersinia enterocolitica w mielonym mi臋sie wo艂owym : badanie aktywno艣ci mikrobiologicznej wybranych linii kom贸rkowych bakterii pod wp艂ywem czynnik贸w fizyko-chemicznych

    No full text
    The main purpose of this study was to examine the efficacy of the pulsed electric field (PEF) on inoculated yersinia enterocolitica ATCC 35669 in minced beef meat. The pulse frequencies ranged from 28 to 2800 MHz. The samples were examined after 3 days of storage in temperature of +4 degrees of Celsius and after 30 days of storage in temperature of - 20 degrees of Celsius. Inactivation of Y. enterocolitica increased with the pulse frequencies. The treatment of meat with the electric field with the pulse frequencies of 28 MHz occurred to be ineffective towards Y. enterocolitica. The treatment of meat with the electric field with the pulse frequencies of 280 MHz occurred to be effective only towards Y. enterocolitica contained in beef meat stored at -20 degrees of Celsius for 30 days. The treatment of meat with the electric field with the pulse frequencies of 2800 MHz occurred to be highly effective towards Y. enterocolitica contained in meat stored both +4 degrees of Celsius and -20 degrees of Celsius.G艂贸wnym celem tego badania by艂a ocena skuteczno艣ci impulsowego pola elektrycznego (PEF) wobec Yersinia enterocolitica ATCC 35669 namno偶onej w mielonym mi臋sie wo艂owym. Cz臋stotliwo艣膰 impuls贸w mie艣ci艂a si臋 w przedziale od 28 do 2800 MHz. Pr贸bki badano po 3 dniach przechowywania w temperaturze +4 stopni Celsjusza i po 30 dniach przechowywania w temperaturze -20 stopni Celsjusza. Y. enterocolitica wykaza艂a wra偶liwo艣膰 na zwi臋kszenie cz臋stotliwo艣ci impuls贸w pola elektrycznego. Y. enterocolitica by艂a wysoce odporna na dzia艂anie pola elektrycznego o cz臋stotliwo艣ci impuls贸w 28 MHz. Potraktowanie mi臋sa polem elektrycznym o cz臋stotliwo艣ci impuls贸w 280 MHz skutkowa艂o inaktywacj膮 Y. enterocolitica obecn膮 w mi臋sie wo艂owym przechowywanym w temperaturze -20 stopni Celsjusza przez 30 dni. Potraktowanie mi臋sa polem elektrycznym o cz臋stotliwo艣ci impuls贸w 2800 MHz okaza艂o si臋 wysoce skuteczne w eliminacji Y. enterocolitica zawartej w mi臋sie przechowywanym zar贸wno w temperaturze +4 stopnie Celsjusza jak i -20 stopni Celsjusza

    Application of pulse radiolysis and vibrational spectroscopy (FT-IR, FT-NIR, FT-Raman) to test the quality of food products

    No full text
    Zapewnienie bezpiecze艅stwa zdrowotnego konsumenta jest podstawowym wymaganiem stawianym producentom 偶ywno艣ci. Bezpiecze艅stwo 偶ywno艣ci zale偶y od czysto艣ci mikrobiologicznej produkt贸w i surowc贸w spo偶ywczych, a tak偶e od obecno艣ci zanieczyszcze艅 chemicznych w 偶ywno艣ci. W pracy om贸wiono metody spektroskopii oscylacyjnej, kt贸re maj膮 zastosowanie w analizie jako艣ci 偶ywno艣ci, s膮 te偶 por臋cznym narz臋dziem w wykrywaniu jej zafa艂szowa艅. Przedstawiono r贸wnie偶 zastosowanie radiolizy impulsowej do bada艅 wp艂ywu wolnych rodnik贸w na w艂a艣ciwo艣ci fizykochemiczne 偶ywno艣ci i jej sk艂adnik贸w.Providing the safety of consumer health is a basic requirement for food producers. Food safety depends on the microbiological purity of food products and raw materials, and the presence of chemical contaminants in food. The paper discusses the method of vibrational spectroscopy, which are applied in the analysis of food quality, there are also a handy tool in the detection of adulteration. It also presents application of pulse radiolysis to study the impact of free radicals on the physicochemical properties of foods and food ingredients

    Application of analytical methods for detecting food irradiation : an overview of recent methods in regard of EU regulations

    No full text
    Napromienianie 偶ywno艣ci jest metod膮 konserwacji o niemal stuletniej tradycji. Pomimo, 偶e zosta艂o zaakceptowane przez organy kontroli jako艣ci w wielu krajach na ca艂ym 艣wiecie, nadal budzi kontrowersje. Nie ulega kwestii, 偶e procesy napromieniania 偶ywno艣ci powinny by膰 monitorowane, a 偶ywno艣膰 sterylizowana radiacyjnie powinna podlega膰 bardzo 艣cis艂ej kontroli jako艣ci. Z tej przyczyny poszukuje si臋 nowych metod wykrywania i dozymetrii napromieniowanej 偶ywno艣ci. Obecnie w艣r贸d metod analitycznych wykrywania 偶ywno艣ci poddanej napromieniowaniu, znormalizowanych przez Europejski Komitet Normalizacyjny (CEN), s膮 tylko dwie metody spektroskopowe: rezonans paramagnetyczny i luminescencja stymulowana 艣wiat艂em, jednak badania wskazuj膮 na mo偶liwo艣膰 zastosowania wielu innych dogodnych rozwi膮za艅 z zastosowaniem m.in. spektroskopii Ramana i widm w bliskiej podczerwieni. Spektroskopowe metody oceny napromieniowanej 偶ywno艣ci daj膮 mo偶liwo艣膰 szybkiego i precyzyjnego wykrycia zastosowanych dawek, dlatego zas艂uguj膮 na zainteresowanie ze strony zespo艂贸w badawczych i wdro偶eniowych. Niniejszy przegl膮d omawia kr贸tko obecny stan naukowy i prawny monitoringu napromieniowania artyku艂贸w 偶ywno艣ciowych w Polsce i na 艣wiecie, a nast臋pnie prezentuje najnowsze doniesienia i osi膮gni臋cia w zakresie zastosowania metod spektroskopowych w ocenie napromienionej 偶ywno艣ci.Food irradiation as a method of preservation is nearly a century old. Although it has been approved by the quality control in many countries around the world, it still remains a matter of controversy. There is no question that the process of food irradiation should be monitored, and irradiated foods should be subject to very strict quality control. For this reason the search for new methods of detection and dosimetry of irradiated foods is required. Currently, among the analytical methods for detecting irradiated foods standardized by the European Committee for Standardization (CEN) only two are the spectroscopic methods: EPR and photostimulated luminescence, but studies indicate the possibility of using a number of other convenient solutions, among others Raman and near-infrared spectra. Spectroscopic methods for assessing irradiated foods make it possible to quickly and accurately detect the applied dose, and shall draw attention of the research and implementation teams. This review briefly discusses the current scientific and legal status of irradiated food monitoring in Poland and worldwide and presents the latest achievements in the application of spectroscopic methods in the evaluation of food irradiation

    mRNA and snRNA Cap Analogs: Synthesis and Applications

    No full text
    corecore