55 research outputs found

    An in vitro comparison between two methods of electrical resistance measurement for occlusal caries detection

    Get PDF
    Because of different measurement techniques and the easier design of the CRM prototype, this in vitro study aimed to compare the diagnostic performance and reproducibility of two electrical methods (Electronic Caries Monitor III, ECM and Cariometer 800, CRM) for occlusal caries detection, and to evaluate the effect of staining/ discoloration of fissures on diagnostic performance. Hundred and seventeen third molars with no apparent occlusal cavitation were selected. Six examiners inspected all specimens independently, using the CRM, and a subgroup of 4 using the ECM. Histological validation using a stereomicroscope was performed after hemisectioning. Intra- and interexaminer reproducibility was assessed by Lin's concordance correlation coefficient (CCC) and Bland and Altman analysis. Diagnostic performance parameters included sensitivity (SE), specificity (SP) and area under the ROC curve (A(z)). The CCC yielded an intra- and interexaminer reproducibility of 0.69/0.62 (ECM) and of 0.79/0.74 (CRM). The mean intra- and interexaminer 95% range of measurements (range between Bland and Altman limits of agreement) given in percentages of the instrument reading were 67%/65% for the ECM and 28%/33% for the CRM. A(z) at the D3-4 level was 0.74 (ECM) and 0.78 (CRM). The CRM showed at least equivalent diagnostic performance to the ECM. However, improvement is still desirable. Diagnostic performance appeared to be enhanced in discolored lesions; however, this may be related to sample lesion distribution characteristics. Copyright (C) 2006 S. Karger AG, Basel

    Effects of dental probing on occlusal surfaces - A scanning electron microscopy evaluation

    Get PDF
    The aim of this clinical-morphological study was to investigate the effects of dental probing on occlusal surfaces by scanning electron microscopy (SEM). Twenty sound occlusal surfaces of third molars and 20 teeth with initial carious lesions of 17- to 26-year-old patients (n = 18) were involved. Ten molars of each group were probed with a sharp dental probe (No. 23) before extraction; the other molars served as negative controls. After extraction of the teeth, the crowns were separated and prepared for the SEM study. Probing-related surface defects, enlargements and break-offs of occlusal pits and fissures were observed on all occlusal surfaces with initial carious lesions and on 2 sound surfaces, respectively. No traumatic defects whatsoever were visible on unprobed occlusal surfaces. This investigation confirms findings of light-microscopic studies that using a sharp dental probe for occlusal caries detection causes enamel defects. Therefore, dental probing should be considered as an inappropriate procedure and should be replaced by a meticulous visual inspection. Critical views of tactile caries detection methods with a sharp dental probe as a diagnostic tool seem to be inevitable in undergraduate and postgraduate dental education programmes. Copyright (c) 2007 S. Karger AG, Basel
    corecore