    Position tracking control in torque mode for a robotic running foot for footwear testing

    Get PDF
    Available automatic footwear testing systems still lack flexibility and bio-fidelity to represent the human foot and reproduce the wear conditions accurately. The first part of this article introduces a new design of the robotic running foot for footwear testing using cable conduit mechanisms. This robotic running foot is integrated with an upper leg mechanism to form a complete integrated footwear testing system. The cable conduit mechanisms help remove the bulky actuators and transmissions out of the fast-moving robotic foot. Thus, this robotic running foot design not only allows high-power actuators to be installed, but also avoids a significant dynamic mass and inertia effects on the upper leg mechanism. This means that the integrated footwear testing system can have multiple powered degrees of freedom in the robotic running foot and simulate much higher human running speeds than other available systems. However, cable conduit mechanisms cause significant challenges in control approaches, especially in high-speed systems, due to their nonlinear transmission characteristics. Furthermore, the robotic running foot actuators must operate in a torque/force control mode to reproduce the foot–shoe interaction during gaits while it is critical to control the foot joints’ position in the swing phase of gaits. The latter part of this article presents a study on position tracking control in torque mode for the robotic running foot joints using adaptive and proportional–integral–derivative control designs to evaluate the system’s ability to mimic the human foot kinematics in running. Both controllers proved their effectiveness, implying that the proposed control approach can be implemented on the integrated footwear testing system to control the foot joints’ position in the swing phase of running gaits

    Direct torque control for cable conduit mechanisms for the robotic foot for footwear testing

    Get PDF
    © 2018 Elsevier Ltd As the shoe durability is affected directly by the dynamic force/pressure between the shoe and its working environments (i.e., the contact ground and the human foot), a footwear testing system should replicate correctly this interaction force profile during gait cycles. Thus, in developing a robotic foot for footwear testing, it is important to power multiple foot joints and to control their output torque to produce correct dynamic effects on footwear. The cable conduit mechanism (CCM) offers great advantages for designing this robotic foot. It not only eliminates the cumbersome actuators and significant inertial effects from the fast-moving robotic foot but also allows a large amount of energy/force to be transmitted/propagated to the compact robotic foot. However, CCMs cause nonlinearities and hysteresis effects to the system performance. Recent studies on CCMs and hysteresis systems mostly addressed the position control. This paper introduces a new approach for modelling the torque transmission and controlling the output torque of a pair of CCMs, which are used to actuate the robotic foot for footwear testing. The proximal torque is used as the input signal for the Bouc–Wen hysteresis model to portray the torque transmission profile while a new robust adaptive control scheme is developed to online estimate and compensate for the nonlinearities and hysteresis effects. Both theoretical proof of stability and experimental validation of the new torque controller have been carried out and reported in this paper. Control experiments of other closed-loop control algorithms have been also conducted to compare their performance with the new controller effectiveness. Qualitative and quantitative results show that the new control approach significantly enhances the torque tracking performance for the system preceded by CCMs
    corecore