14 research outputs found

    Radiographic parameter(s) influencing functional outcomes following angular stable plate fixation of proximal humeral fractures

    No full text
    Abstract Purpose Radiographic parameters which correlate with poor clinical outcome after proximal humeral fractures could be helpful indicators to answer the question which patients should be followed up closer. Moreover, during surgery, radiographic parameters correlating with unfavourable outcome should be avoided. The primary aim of the study was to compare radiographic measurements between the injured and the contralateral, uninjured shoulder. The secondary aim was to correlate these radiographic parameters with post-operative shoulder function. Methods Fifty-eight patients (age: 55.6 ± 14.4 years, age at surgery) following angular stable plate fixation of a proximal humeral fracture (2-part fractures according to Neer: 24, 3-part: 25, 4-part: 9) were included in this retrospective cohort study. All patients were followed up at least six years (7.9 ± 1.4 after surgical intervention). During follow-up examination, the Constant score (CS) was assessed, and radiographs of both shoulders were taken. Radiographs were analyzed regarding lateral humeral offset, distance between tuberculum and head apex, head diameter, head height, perpendicular height, perpendicular center, vertical height, and angles between head and humeral shaft (CCD and HSA). These parameters were compared between the injured and uninjured shoulder. The cohort was divided in two groups: patients with a CS category of excellent/good and satisfying/worse. Both groups were tested regarding differences of demographic and radiographic parameters. Results The distance between tuberculum and head apex (2.6 ± 3.4 mm vs. 4.3 ± 2.1 mm; p = 0.0017), the CCD (123.1 ± 12.9° vs. 130.1 ± 7.3°; p = 0.0005), and the HSA (33.1 ± 12.8° vs. 40.1 ± 7.3°; p = 0.0066) were significantly smaller on the treated shoulder compared to the uninjured side. Patients reached a Constant score of 80.2 ± 17.4 (95% CI 75.6–84.8) points. Regarding outcome categories of the Constant score, 46 patients had a good to excellent outcome, and 12 patients had a satisfying or bad outcome. The comparison of these groups revealed that patients with inferior outcome in the long-term follow-up were older, female, had a more complex fracture type (AO classification), smaller lateral humeral offset, smaller head diameter and height, lower perpendicular height, and lower CCD and HSA angles. Conclusion If the abovementioned parameters cannot be restored sufficiently during surgery, (reversed) shoulder arthroplasty might be a better solution to reach good post-operative outcome. Moreover, patients presenting these radiographic characteristics in the follow-up, older patients, and patients with a more complex fracture type should be followed up closer to possibly prevent poor shoulder function. Trial registration: 83 250/2011BO2 </jats:sec

    Radiographic parameter(s) influencing functional outcomes following angular stable plate fixation of proximal humeral fractures

    No full text
    PURPOSE: Radiographic parameters which correlate with poor clinical outcome after proximal humeral fractures could be helpful indicators to answer the question which patients should be followed up closer. Moreover, during surgery, radiographic parameters correlating with unfavourable outcome should be avoided. The primary aim of the study was to compare radiographic measurements between the injured and the contralateral, uninjured shoulder. The secondary aim was to correlate these radiographic parameters with post-operative shoulder function. METHODS: Fifty-eight patients (age: 55.6 ± 14.4 years, age at surgery) following angular stable plate fixation of a proximal humeral fracture (2-part fractures according to Neer: 24, 3-part: 25, 4-part: 9) were included in this retrospective cohort study. All patients were followed up at least six years (7.9 ± 1.4 after surgical intervention). During follow-up examination, the Constant score (CS) was assessed, and radiographs of both shoulders were taken. Radiographs were analyzed regarding lateral humeral offset, distance between tuberculum and head apex, head diameter, head height, perpendicular height, perpendicular center, vertical height, and angles between head and humeral shaft (CCD and HSA). These parameters were compared between the injured and uninjured shoulder. The cohort was divided in two groups: patients with a CS category of excellent/good and satisfying/worse. Both groups were tested regarding differences of demographic and radiographic parameters. RESULTS: The distance between tuberculum and head apex (2.6 ± 3.4 mm vs. 4.3 ± 2.1 mm; p = 0.0017), the CCD (123.1 ± 12.9° vs. 130.1 ± 7.3°; p = 0.0005), and the HSA (33.1 ± 12.8° vs. 40.1 ± 7.3°; p = 0.0066) were significantly smaller on the treated shoulder compared to the uninjured side. Patients reached a Constant score of 80.2 ± 17.4 (95% CI 75.6–84.8) points. Regarding outcome categories of the Constant score, 46 patients had a good to excellent outcome, and 12 patients had a satisfying or bad outcome. The comparison of these groups revealed that patients with inferior outcome in the long-term follow-up were older, female, had a more complex fracture type (AO classification), smaller lateral humeral offset, smaller head diameter and height, lower perpendicular height, and lower CCD and HSA angles. CONCLUSION: If the abovementioned parameters cannot be restored sufficiently during surgery, (reversed) shoulder arthroplasty might be a better solution to reach good post-operative outcome. Moreover, patients presenting these radiographic characteristics in the follow-up, older patients, and patients with a more complex fracture type should be followed up closer to possibly prevent poor shoulder function. Trial registration: 83 250/2011BO

    Contrast-enhanced spectral mammography in patients with MRI contraindications

    No full text
    Background Contrast-enhanced spectral mammography (CESM) is a novel breast imaging technique providing comparable diagnostic accuracy to breast magnetic resonance imaging (MRI). Purpose To show that CESM in patients with MRI contraindications is feasible, accurate, and useful as a problem-solving tool, and to highlight its limitations. Material and Methods A total of 118 patients with MRI contraindications were examined by CESM. Histology was obtained in 94 lesions and used as gold standard for diagnostic accuracy calculations. Imaging data were reviewed retrospectively for feasibility, accuracy, and technical problems. The diagnostic yield of CESM as a problem-solving tool and for therapy response evaluation was reviewed separately. Results CESM was more accurate than mammography (MG) for lesion categorization (r = 0.731, P &lt; 0.0001 vs. r = 0.279, P = 0.006) and for lesion size estimation (r = 0.738 vs. r = 0.689, P &lt; 0.0001). Negative predictive value of CESM was significantly higher than of MG (85.71% vs. 30.77%, P &lt; 0.0001). When used for problem-solving, CESM changed patient management in 2/8 (25%) cases. Superposition artifacts and timing problems affected diagnostic utility in 3/118 (2.5%) patients. Conclusion CESM is a feasible and accurate alternative for patients with MRI contraindications, but it is necessary to be aware of the method’s technical limitations. </jats:sec

    BI-RADS similar to 3 lesions at contrast-enhanced breast MRI: is an initial short-interval follow-up necessary?

    No full text
    Background Magnetic resonance imaging (MRI) BI-RADS® 3 lesions should have a very high probability of being benign. To prove benignity most institutions do follow-up MRI. Purpose To evaluate the necessity of initial short-interval follow-up after 6 months as it is suggested for mammographic BI-RADS®3 lesions. Material and Methods We analyzed 163 consecutive MRI-BI-RADS® 3 lesions on follow-up MRI: 75 masses (46%), 67 foci (41.1%), and 21 (12.9%) non-mass-like enhancing lesions (NMLE). Results During MRI follow-up (mean time, 563 days) 20% of the lesions disappeared, 23% decreased, 52% did not change, and 4.9% showed increase. All increasing lesions were biopsied (5 benign, 2 ductal carcinoma in situ, 1 invasive carcinoma). The rate of malignancy was 1.8%. All malignant lesions (1 mass, 1 focus, 1 NMLE) showed increase at initial follow-up after a mean interval of 190 days. Conclusion In this study the malignancy rate of MRI-BI-RADS® 3 lesions corresponded to mammographic BI-RADS® 3 lesions. Initial short-interval MRI should be suggested to identify malignant MRI-BI-RADS® 3 lesions. </jats:sec
    corecore