32 research outputs found

    The Application of a Three-Step Proteome Analysis for Identification of New Biomarkers of Pancreatic Cancer

    Get PDF
    We searched for novel tumor markers of pancreatic cancer by three-step serum proteome analysis. Twelve serum abundant proteins were depleted using immunoaffinity columns followed by fractionation by reverse-phase high-performance liquid chromatography. Proteins in each fraction were separated by two-dimensional gel electrophoresis. Then the gel was stained by Coomassie Brilliant Blue. Protein spots in which the expression levels were significantly different between cancer and normal control were identified by LC-MS/MS. One hundred and two spots were upregulated, and 84 spots were downregulated in serum samples obtained from patients with pancreatic cancers, and 58 proteins were identified by mass spectrometry. These candidate proteins were validated using western blot analysis and enzyme-linked immunosorbent assay (ELISA). As a result of these validation process, we could confirm that the serum levels of apolipoprotein A-IV, vitamin D-binding protein, plasma retinol-binding protein 4, and tetranectin were significantly decreased in patients with pancreatic cancer

    Adsorption of Urinary Proteins on the Conventionally Used Urine Collection Tubes: Possible Effects on Urinary Proteome Analysis and Prevention of the Adsorption by Polymer Coating

    Get PDF
    One possible factor determining recovery of trace amount of protein biomarker candidates during proteome analyses could be adsorption on urine tubes. This issue, however, has not been well addressed so far. Recently, a new technical device of surface coating by poly(2-methacryloyloxyethyl phosphorylcholine (MPC)-co-n-butyl methacrylate (BMA)) (poly(MPC-co-BMA)) has been developed mainly to prevent the adsorption of plasma proteins. We assessed whether conventionally used urine tubes adsorb trace amount of urinary proteins and, if any, whether the surface coating by poly(MPC-co-BMA) can minimize the adsorption. Proteinuric urine samples were kept in poly(MPC-co-BMA)-coated and noncoated urine tubes for 15 min and possibly adsorbed proteins and/or peptides onto urine tubes were analyzed by SDS-PAGE, 2-DE, and the MALDI-TOF MS. It was found that a number of proteins and/or peptides adsorb on the conventionally used urine tubes and that surface coating by poly(MPC-co-BMA) can minimize the adsorption without any significant effects on routine urinalysis test results. Although it remains to be clarified to what extent the protein adsorption can modify the results of urinary proteome analyses, one has to consider this possible adsorption of urinary proteins when searching for trace amounts of protein biomarkers in urine

    Decreases in the Serum VLDL-TG/Non-VLDL-TG Ratio from Early Stages of Chronic Hepatitis C: Alterations in TG-Rich Lipoprotein Levels

    Get PDF
    BACKGROUND: The liver secretes very-low-density lipoproteins (VLDLs) and plays a key role in lipid metabolism. Plasma total triglyceride (TG) level variations have been studied in patients with hepatitis C virus (HCV)-related chronic hepatitis (CH-C). However, the results of these studies are variable. A homogenous assay protocol was recently proposed to directly measure the TG content in VLDL (VLDL-TG) and VLDL remnants. METHODOLOGY/PRINCIPAL FINDINGS: Using the assay protocol, we determined serum VLDL-TG levels in 69 fasting patients with biopsy-proven HCV-related chronic liver disease and 50 healthy subjects. Patients were classified into stages F0-F4 using the 5-point Desmet scale. Serum total TG levels in patients with non-cirrhotic (F1-F3) CH-C did not demonstrate significant differences compared with healthy subjects, but serum VLDL-TG levels did demonstrate significant differences. Mean serum VLDL-TG levels tended to decrease with disease progression from F1 to F4 (cirrhosis). Compared with healthy subjects, serum non-VLDL-TG levels significantly increased in patients with stages F2 and F3 CH-C; however, we observed no significant difference in patients with liver cirrhosis. Furthermore, the serum VLDL-TG/non-VLDL-TG ratio, when taken, demonstrated a significant decrease in patients with CH-C from the mildest stage F1 onward. CONCLUSIONS/SIGNIFICANCE: The decrease in serum VLDL-TG levels was attenuated by increase in non-VLDL-TG levels in patients with non-cirrhotic CH-C, resulting in comparable total TG levels. Results of previous studies though variable, were confirmed to have a logical basis. The decrease in the serum VLDL-TG/non-VLDL-TG ratio as early as stage F1 demonstrated TG metabolic alterations in early stages of CH-C for the first time. The involvement of TG metabolism in CH-C pathogenesis has been established in experimental animals, while conventional TG measurements are generally considered as poor indicators of CH-C progression in clinical practice. The serum VLDL-TG/non-VLDL-TG ratio, which focuses on TG metabolic alterations, may be an early indicator of CH-C

    Inhibitory Activity of Hydroxytyrosol against Streptolysin O-Induced Hemolysis

    No full text

    Usefulness of the MALDI-TOF MS technology with membrane filter protocol for the rapid identification of microorganisms in perioperative drainage fluids of hepatobiliary pancreatic surgery.

    No full text
    Surgical site infections (SSIs) are significant and frequent perioperative complications, occurring due to the contamination of the surgical site. The late detection of SSIs, especially organ/space SSIs which are the more difficult to treat, often leads to severe complications. An effective method that can identify bacteria with a high accuracy, leading to the early detection of organ/space SSIs, is needed. Ninety-eight drainage fluid samples obtained from 22 patients with hepatobiliary pancreatic disease were analyzed to identify microorganisms using matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) with a new membrane filtration protocol and rapid BACpro® pretreatment compared to sole rapid BACpro® pretreatment. The levels of detail of rapid BACpro® pretreatment with or without filtration were also evaluated for the accuracy of bacterial identification. We found that reliable scores for E. coli and E. faecalis were obtained by inoculation with 1.0 × 104 CFU/ml after preparation of the membrane filter with rapid BACpro®, indicating approximately 10-folds more sensitive compared to sole rapid BACpro® pretreatment in drainage fluid specimens. Among 60 bacterial positive colonies in drainage fluid specimens, the MALDI-TOF MS and the membrane filtration with rapid BACpro® identified 53 isolates (88.3%) with a significantly higher accuracy, compared to 25 isolates in the rapid BACpro® pretreatment group (41.7%) (p < 0.001). Among the 78 strains, 14 enteric Gram-negative bacteria (93.0%) and 55 Gram-positive cocci (87.3%) were correctly identified by the membrane filtration with rapid BACpro® with a high reliability. This novel protocol could identify bacterial species within 30 min, at 22-3 per sample, thus leading to cost and time savings. MALDI-TOF MS with membrane filter and rapid BACpro® is a quick and reliable method for bacterial identification in drainage fluids. The shortened analysis time will enable earlier selection of suitable antibiotics for treatment of organ/space SSIs to improve patients' outcomes
    corecore