8 research outputs found

    Preliminary study of thrombogenicity induced by the nanoparticle surface coating of intracranial stents

    Get PDF
    Endovascular treatment of intracranial aneurysms with intracranial stents was proven to be clinically safe and effective, but is still associated with a risk of thromboembolic complications. Stent thrombosis could be a sever complication associated with specific stent surface coatings and designs. Standardized in vitro tests for investigation of thrombogenicity induced by different nanomaterials were used as the basic method in carrying out the present study. Therefore, the aim of this study was to evaluate the thrombogenicity of three different nanomaterials (ZnO, TiO2 si Fe3O4) possible used as surface coating for intracranial stents. This study is based on a procedure for in vitro analyses of plasma coagulation time. To measure the plasma coagulation time, platelet-poor plasma from human whole blood was in vitro exposed to nanoparticles and analysed in prothrombin (PT) and activated partial thromboplastin (APTT)

    Processing Effects on the Martensitic Transformation and Related Properties in the Ni<sub>55</sub>Fe<sub>18</sub>Nd<sub>2</sub>Ga<sub>25</sub> Ferromagnetic Shape Memory Alloy

    No full text
    The influence of processing on the martensitic transformation and related magnetic properties of the Ni55Fe18Nd2Ga25 ferromagnetic shape memory alloy, as bulk and ribbons prepared by the melt spinning method and subjected to different thermal treatments, is investigated. Structural, calorimetric, and magnetic characterizations are performed. Thermal treatment at 1173 K induces a decrease in both the Curie and the martensitic transformation temperatures, while a treatment at 673 K produces the structural ordering of the ribbons, hence an increase in TC. A maximum value of the magnetic entropy variation of −5.41 J/kgK was recorded at 310 K for the as quenched ribbons. The evaluation of the magnetoresistive effect shows a remarkable value of −13.5% at 275 K on the bulk sample, which is much higher than in the ribbons

    Magnetic and Magnetostrictive Properties of Ni50Mn20Ga27Cu3 Rapidly Quenched Ribbons

    No full text
    The influence of the rapid solidification technique and heat treatment on the martensitic transformation, magnetic properties, thermo- and magnetic induced strain and electrical resistivity is investigated for the Cu doped NiMnGa Heusler-based ferromagnetic shape memory ribbons. The martensitic transformation temperatures are unexpectedly low (below 90 K—which can be attributed to the disordered texture as well as to the uncertainty in the elements substituted by the Cu), preceded by a premartensitic transformation (starting at around 190 K). A thermal treatment slightly increases the transformation as well as the Curie temperatures. Additionally, the thermal treatment promotes a higher magnetization value of the austenite phase and a lower one in the martensite. The shift of the martensitic transformation temperatures induced by the applied magnetic field, quantified from thermo-magnetic and thermo-magnetic induced strain measurements, is measured to have a positive value of about 1 K/T, and is then used to calculate the transformation entropy of the ribbons. The magnetostriction measurements suggest a rotational mechanism in low fields for the thermal treated samples and a saturation tendency at higher magnetic fields, except for the temperatures close to the phase transition temperatures (saturation is not reached at 5 T), where a linear volume magnetostriction cannot be ruled out. Resistivity and magnetoresistance properties have also been measured for all the samples

    Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant

    No full text
    Durable biocompatible metal vascular implants are still one of the significant challenges of contemporary medicine. This work presents the preparation of ferromagnetic biomaterials with shape memory in metal strips based on FePd (30 at% Pd) that is either not doped or doped with Ga and Mn, coated with poly(benzofuran-co-arylacetic acid) or polyglutamic acid. The coating of the metal strips with polymers was achieved after the metal surface had been previously treated with open-air cold plasma. The final functionalization was performed to induce anti-thrombogenic/thrombolytic properties in the resulting materials. SEM-EDX microscopy and X-ray photoelectron microscopy (XPS) determined the morphology and composition of the metal strips covered with polymers. In vitro tests of standardized thromboplastin time (PTT) and prothrombin time (PT) were performed to evaluate the thrombogenicity of these biofunctionalized materials for future possible monitoring of the implant in patients

    Anticoagulant Properties of Coated Fe-Pd Ferromagnetic Shape Memory Ribbons

    No full text
    Shape memory alloys, especially ferromagnetic shape memory alloys, are interesting new materials for the manufacturing of stents. Iron–palladium alloys in particular can be used to manufacture self-expanding temporary stents due to their optimum rate of degradation, which is between that of magnesium and pure iron, two metals commonly used in temporary stent research. In order to avoid blood clotting upon the introduction of the stent, they are often coated with anticoagulants. In this study, sulfated pectin, a heparin mimetic, was synthesized in different ways and used as coating on multiple iron–palladium alloys. The static and dynamic prothrombin time (PT) and activated partial thromboplastin time (APTT) of the prepared materials were compared to samples uncoated or coated with polyethylene glycol. While no large differences were observed in the prothrombin time measurements, the activated partial thromboplastin time increased significantly with all alloys coated with sulfated pectin. Aside from that, sulfated pectin synthesized by different methods also caused slight changes in the activated partial thromboplastin time. These findings show that iron–palladium alloys can be coated with anticoagulants to improve their utility as material for temporary stents. Sulfated pectin was characterized by nuclear magnetic resonance (NMR) and Fourier-transform infrared (FTIR) spectroscopy, and the coated alloys by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX)

    Kinetics and the Effect of Thermal Treatments on the Martensitic Transformation and Magnetic Properties in Ni<sub>49</sub>Mn<sub>32</sub>Ga<sub>19</sub> Ferromagnetic Shape Memory Ribbons

    No full text
    In our work, the kinetics of martensitic transformations and the influence of thermal treatments on martensitic transformations, as well as the related magnetic properties of the Ni49Mn32Ga19 ferromagnetic shape memory melt-spun ribbons, have been investigated. Thermal treatments at 673 K for 1, 4 and 8 h can be considered an instrument for fine-tuning the performance parameters of alloys. One-hour thermal treatments promote an improvement in the crystallinity of these otherwise highly textured ribbons, reducing internal defects and stress induced by the melt-spinning technique. Longer thermal treatments induce an important magnetization rise concomitantly with a slight and continuous increase in martensitic temperatures and transformation enthalpy. The activation energy, evaluated from differential scanning calorimeter experimental data with a Friedman model, significantly increases after thermal treatments as a result of the multi-phase coexistence and stabilization of the non-modulated martensitic phase, which increases the reverse martensitic transformation hindrance

    Anticoagulant Properties of Coated Fe-Pd Ferromagnetic Shape Memory Ribbons

    No full text
    Shape memory alloys, especially ferromagnetic shape memory alloys, are interesting new materials for the manufacturing of stents. Iron&ndash;palladium alloys in particular can be used to manufacture self-expanding temporary stents due to their optimum rate of degradation, which is between that of magnesium and pure iron, two metals commonly used in temporary stent research. In order to avoid blood clotting upon the introduction of the stent, they are often coated with anticoagulants. In this study, sulfated pectin, a heparin mimetic, was synthesized in different ways and used as coating on multiple iron&ndash;palladium alloys. The static and dynamic prothrombin time (PT) and activated partial thromboplastin time (APTT) of the prepared materials were compared to samples uncoated or coated with polyethylene glycol. While no large differences were observed in the prothrombin time measurements, the activated partial thromboplastin time increased significantly with all alloys coated with sulfated pectin. Aside from that, sulfated pectin synthesized by different methods also caused slight changes in the activated partial thromboplastin time. These findings show that iron&ndash;palladium alloys can be coated with anticoagulants to improve their utility as material for temporary stents. Sulfated pectin was characterized by nuclear magnetic resonance (NMR) and Fourier-transform infrared (FTIR) spectroscopy, and the coated alloys by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX)

    Magnetic Shape Memory Nanocomposites Assembled with High Speed High Pressure Torsion

    No full text
    When a severe plastic deformation (SPD) process is performed at high temperatures, it becomes more versatile. Designed originally for the bulk nanoconstruction of hard-to-deform alloys, high-speed high-pressure torsion (HSHPT) is an SPD method used in this research for assembling multiple layers of shape memory nanocomposites. Three hard-to-deform magnetic alloys in the cast state were used. Soft magnetic shape memory alloys, NiFeGa and FePdMn, and a potentially hard magnetic alloy, CoZr, were assembled in various composites. Both grain refinement and strong layer bonding were achieved in ZrCo/FePdMn and ZrCo/NiFeGa composites in seconds. The very short SPD time is specific to HSHPT because of the intense friction that occurs under high pressures, which generates huge amounts of heat. After SPD, the temperature rises in bulk material like a pulse, being dissipated mostly through heat conduction. The SPD parameters were carefully controlled with an advanced automation system using a programmable logic controller. Nevertheless, the major drawbacks of high-pressure torsion were overcome, and large SPD discs were obtained. Various investigation techniques (optical microscopy, scanning electron microscopy, energy dispersive spectroscopy and atomic force microscopy) show well-defined interfaces as well as a fine and ultrafine structure
    corecore