    The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review

    Get PDF
    BackgroundTo assess the Nickel sensitizing potential of total knee arthroplasty (TKA), explore the relationship between hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or postoperatively.Materials and methodsA literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. The level of evidence of studies was assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the quality evaluated using the Methodological Index for Non-randomized Studies and Cochrane risk-of-bias tools.ResultsTwenty studies met the eligibility criteria, reporting on 1354 knee arthroplasties. Studies included patients undergoing primary or revision TKA, pre- and/or postoperatively, and used patch testing to identify Nickel hypersensitivity. Prevalence of Nickel hypersensitivity ranged from 0% to 87.5%. One study compared the prevalence of Nickel hypersensitivity in the same patient group before and after surgery and noted newly positive patch test reactions in three patients (4.2%). Three studies reported lower prevalence of Nickel hypersensitivity in postoperative patients compared to preoperative ones. Seven studies suggested that hypersensitivity might cause adverse clinical outcomes, but six did not support any relationship. Seven studies recommended preoperative patch testing in patients with history of metal allergy, and nine concluded that testing may be valuable postoperatively.ConclusionsPatients undergoing TKA with no prior history of metal hypersensitivity do not seem to be at an increased risk of developing Nickel hypersensitivity, and there is conflicting evidence that patients with pre-existing hypersensitivity are more likely to experience adverse outcomes. Patch testing remains the most commonly used method for diagnosing hypersensitivity, and evidence suggests preoperative testing in patients with history of metal allergy to aid prosthesis selection, and postoperatively in patients with suspected hypersensitivity once common causes of implant failure have been excluded, since revision with hypoallergenic implants may alleviate symptoms

    Validation of a 3D CT method for measurement of linear wear of acetabular cups: A hip simulator study

    Get PDF
    Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17?. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy

    Metal on metal hip resurfacing versus uncemented custom total hip replacement - early results

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA) of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR) has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been encouraging. We have compared two well matched cohorts of patients with regard to function, pain relief and patient satisfaction.</p> <p>Methods</p> <p>This prospective study compares 2 cohorts of young, active patients treated with hip resurfacing (137 patients, 141 hips) and custom uncemented (CADCAM) stems (134 patients, 141 hips). All procedures were performed by a single surgeon. Outcome measures included Oxford, WOMAC and Harris hip scores as well as an activity score. Statistical analysis was performed using the unpaired student's t-test.</p> <p>Results</p> <p>One hundred and thirty four and 137 patients were included in the hip replacement and resurfacing groups respectively. The mean age of these patients was 54.6 years. The mean duration of follow up for the hip resurfacing group was 19.2 months compared to 13.4 months for the total hip replacement group.</p> <p>Pre operative oxford, Harris and WOMAC scores in the THA group were 41.1, 46.4 and 50.9 respectively while the post operative scores were 14.8, 95.8 and 5.0. In the HR group, pre- operative scores were 37.0, 54.1 and 45.9 respectively compared to 15.0, 96.8 and 6.1 post operatively. The degree of improvement was similar in both groups.</p> <p>Conclusion</p> <p>There was no significant clinical difference between the patients treated with hip resurfacing and total hip arthroplasty in the short term.</p

    Analysis of polyethylene wear in plain radiographs: The number of radiographs influences the results

    Get PDF
    Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs

    Prevention of Wear Particle-Induced Osteolysis by a Novel V-ATPase Inhibitor Saliphenylhalamide through Inhibition of Osteoclast Bone Resorption

    Get PDF
    Wear particle-induced peri-implant loosening (Aseptic prosthetic loosening) is one of the most common causes of total joint arthroplasty. It is well established that extensive bone destruction (osteolysis) by osteoclasts is responsible for wear particle-induced peri-implant loosening. Thus, inhibition of osteoclastic bone resorption should prevent wear particle induced osteolysis and may serve as a potential therapeutic avenue for prosthetic loosening. Here, we demonstrate for the first time that saliphenylhalamide, a new V-ATPase inhibitor attenuates wear particle-induced osteolysis in a mouse calvarial model. In vitro biochemical and morphological assays revealed that the inhibition of osteolysis is partially attributed to a disruption in osteoclast acidification and polarization, both a prerequisite for osteoclast bone resorption. Interestingly, the V-ATPase inhibitor also impaired osteoclast differentiation via the inhibition of RANKL-induced NF-κB and ERK signaling pathways. In conclusion, we showed that saliphenylhalamide affected multiple physiological processes including osteoclast differentiation, acidification and polarization, leading to inhibition of osteoclast bone resorption in vitro and wear particle-induced osteolysis in vivo. The results of the study provide proof that the new generation V-ATPase inhibitors, such as saliphenylhalamide, are potential anti-resorptive agents for treatment of peri-implant osteolysis
    • …