10 research outputs found

    Electronic instabilities and structural fluctuations in self-assembled atom wires

    No full text
    One-dimensional (1D) solid state systems can behave drastically different from their higher dimensional counterparts. Increased interactions can produce electronic and/or structural instabilities. In this respect, the following fundamental questions are important for a proper understanding of the properties of the ultimate 1D systems consisting of atom wires: Are atom wires created by self-assembly on silicon (Si) surfaces actually stable? Do atom wires exist that are metallic (at low temperatures)? What role is played by defects in these atom wires? This Thesis attempts to find an answer to these questions. Atom wires were realized by self-assembly on vicinal Si surfaces. Using Scanning Tunneling Microscopy and Spectroscopy combined with Density Functional Theory calculations, a full analysis of the (thermodynamic) stability of Gallium (Ga) atom wires on Si(112) has been made, including the energetics of fluctuating intrinsic structural defects. It is shown that the stable atom wires fully passivate the surface, and that the spacing between intrinsic quasi-1D meandering vacancy lines can be tuned continuously through experimental adjustment of the Ga chemical potential. Gold atom wires on the Si(553) surface show an incommensurate metallic state at room temperature. Decreasing the temperature, two competing charge density waves (CDW) within single atom wires are observed, accompanied by a third CDW coexisting in between those wires. Defects in the atom wires induce interband charge transfer, resulting in commensurate CDWs at low temperatures. Finally, manipulatable phase slips with fractional charge and spin are observed for the first time in a CDW in real space.Applied Science

    On the development of aluminium oxide film structure from X-ray photoelectron spectra

    No full text
    Mechanical, Maritime and Materials EngineeringTechnische Materiaalwetenschappe

    Density waves in atomic necklaces

    No full text
    kavli institute of nanoscienceApplied Science

    Trigonometric algorithm defining the true three-dimensional acetabular cup orientation: Correlation between measured and calculated cup orientation angles

    No full text
    Background: Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept involving a trigonometric description enables unambiguous definitions. Our objective was to test the validity and reliability of a 3D trigonometric description of cuporientation.Methods: Computed tomographic scans of the pelvis, performed for vascular assessment of 20 patients with 22 primary total hip replacements in situ, were systematically collected. On multiplanar reconstructions, 3 observers independently measured cup orientation retrospectively in terms of coronal inclination, sagittal tilt, and transverse version. The angles measured in 2 planes were used to calculate the angle in the third plane via a trigonometric algorithm. For correlation and reliability analyses, intraobserver and interobserver differences between measured and calculated angles were evaluated with use of the intraclass correlation coefficient (ICC).Results: Measured and calculated angles had ICCs of 0.953 for coronal inclination, 0.985 for sagittal tilt, and 0.982 for transverse version. Intraobserver and interobserver reliability had ICCs of 0.987 and 0.987, respectively, for coronal inclination; 0.979 and 0.981, respectively, for sagittal tilt; and 0.992 and 0.978, respectively, for transverse version.Conclusions: The 3D concept with its trigonometric algorithm is a valid and reliable tool for the measurement of cup orientation.Clinical Relevance: By calculating the transverse version of cups from coronal inclination and sagittal tilt measurements, the trigonometric algorithm enables a 3D definition of cup orientation, regardless of the imaging modality used. In addition, it introduces sagittal tilt that, like pelvic tilt, rotates around the transverse axis.Biomaterials & Tissue Biomechanic

    The role of the femoral component orientation on dislocations in THA: a systematic review

    No full text
    Introduction: Dislocation remains a major complication in total hip arthroplasty (THA), in which femoral component orientation is considered a key parameter. New imaging modalities and definitions on femoral component orientation have been introduced, describing orientation in different planes. This study aims to systematically review the relevance of the different orientation parameters on implant stability. Methods: A systematic review was performed according to the PRISMA guidelines to identify articles in the PubMed and EMBASE databases that study the relation between any femoral component orientation parameters and implant stability in primary THA. Results: After screening for inclusion and exclusion criteria and quality assessment, nine articles were included. Definitions to describe the femoral component orientation and methodologies to assess its relevance for implant stability differed greatly, with lack of consensus. Seven retrospective case–control studies reported on the relevance of the transversal plane orientation: Low femoral- or low combined femoral and acetabular anteversion was statistical significantly related with more posterior dislocations, and high femoral- or combined femoral and acetabular anteversion with anterior dislocations in two studies. There were insufficient data on sagittal and coronal component orientation in relation to implant stability. Conclusion: Because of incomparable definitions, limited quality and heterogeneity in methodology of the included studies, there is only weak evidence that the degree of transverse component version is related with implant stability in primary THA. Recommendations about the optimal orientation of the femoral component in all three anatomical planes cannot be provided. Future studies should uniformly define the three-dimensional orientation of the femoral component and systematically describe implant stability.Biomaterials & Tissue Biomechanic

    Non-equivalent results from different anteversion measurements methods for the evaluation of the acetabular cup orientation in total hip arthroplasty

    No full text
    Objective: To determine the comparability among 10 radiographic anteversion methods for acetabular cup orientation in total hip arthroplasty (THA) found in the literature and the “gold” standard of assessing the anteversion with CT. Methods: This is a retrospective study that blindly compares 10 different conventional radiographic anteversion measurements with the “gold” standard, the measurement of anteversion on the transverse plane of the 3-D images made with CT. The patient archiving and communications system (PACS) was systematically searched for subjects that had undergone a CT angiogram of the abdomen and lower extremities, including the pelvis, had at least one THA in situ and had undergone anterior-posterior (AP) and cross-lateral pelvic radiography between January 2013 and August 2016 in the Diakonessenhuis Hospital Utrecht/Zeist, a non-academic institution. CT scans of patients (n = 16) were systematically collected. Three observers independently measured cup anteversion from radiographs, using a total of 10 different methods, and measured the “gold” standard on CT images. The outcomes of the 10 radiographic anteversion were compared in terms of linear correlation with the “gold” standard on CT images. Results: The correlations of the radiographic measured anteversions with the “gold” standard measured on CT images were 0.528 for the method of Liaw, 0.556 for Wan, 0.562 for the cross-lateral method, 0.586 for Hassan, 0.594 for Dorr, 0.602 for Lewinnek, 0.624 for Widmer, 0.671 for the lateral CT, 0.747 for Ackland, and 0.771 for the method of Riten Pradham. Conclusion: Anteversion measurement methods represent different projectional angles of the acetabular cup in different planes around different axes. Therefore, they differ from the “gold” standard and are not interchangeable, as is shown by this study. We consider the anatomical anteversion in the transverse plane rotating around the longitudinal axis as the “gold” standard and recommend avoiding using the term anteversion for other projectional angles in different planes.Biomaterials & Tissue Biomechanic

    Current Evidence for Spinopelvic Characteristics Influencing Total Hip Arthroplasty Dislocation Risk

    No full text
    BACKGROUND: Decreased pelvic mobility and pelvic retroversion may result from spinal degeneration and lead to changes in the orientation of the acetabular implant after total hip arthroplasty (THA). While multiple patient and surgery-related factors contribute to THA dislocations, there is increasing evidence that sagittal spinopelvic dynamics are relevant for THA stability. The aim of this systematic review was to assess the relationship between previously described sagittal spinopelvic characteristics and implant dislocations after primary THA. METHODS: A comprehensive literature search in the PubMed and Embase databases was conducted for studies reporting on spinopelvic morphology, alignment, pathology, or surgery and THA dislocations. Risk of bias was assessed using the MINORS criteria. Because of high heterogeneity in study methodology, a synthesis of best evidence was performed. Odds ratios (ORs), relative risks (RRs), and effect sizes (g) were calculated. RESULTS: Fifteen studies (1,007,900 THAs) with quality scores of 15 to 23 out of 24 were included. Nine different spinopelvic alignment parameters (8 studies, g = 0.14 to 2.02), spinal pathology (2 studies, OR = 1.9 to 29.2), and previous spinal fusion surgery (8 studies, OR = 1.59 to 23.7, RR = 3.0) were found to be related to THA dislocation. Conflicting results were found for another sagittal pelvic morphology parameter, pelvic incidence. CONCLUSIONS: Several sagittal spinopelvic patient characteristics were found to be related to THA dislocation, and the associated risks were greater than for other patient and surgery-related factors. Future research is needed to determine which of those characteristics and parameters should be taken into account in patients undergoing primary THA. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Biomaterials & Tissue Biomechanic

    Calculation of the 3-D femoral component's orientation in total hip arthroplasty using a trigonometric algorithm

    No full text
    Femoral component orientation plays a key role in implant stability and therefore the success rate of total hip arthroplasty. To date, this topic has been studied using various definitions and a variety of imaging modalities and protocols. The aim of this study is a proof of concept that a new algorithm can be used to describe the femoral component's 3D orientation on the three orthogonal anatomical planes and relative to its mechanical axis using input from two orthogonal planes. CT scans of 18 patients with a total of 22 hip arthroplasties were collected. From these, orthogonal coronal and sagittal projections of the complete femur were acquired in the scanning position (MIPs) and relative to the femoral mechanical axis (corrected MIPs). On these images, the orientation of the neck of the femoral component in space and relative to the femoral axis, respectively, was measured by coronal inclination (CIF), sagittal inclination (SIF) and transverse version (TVF). With the algorithm, TVF was also calculated based on CIF and SIF. Differences between measured and calculated TVF and intra- and inter-observer reliability were evaluated using intra-class correlation coefficients (ICC). The error of non-orthogonal imaging (85° angle between the sagittal and coronal reconstructions) was tested on a third series of MIPs. The ICC between the calculated TVF and manually measured TVF, in space and relative to the femoral axis, was 0.98 for both with median absolute differences of 1.3 and 1.5°. For non-orthogonal images this was 0.70 with a median absolute difference of 5°. ICCs for intra-observer and inter-observer reliability for the calculated TVF values were 0.98 and 0.88, respectively. With this algorithm the transverse orientation of the neck of the femoral component can be assessed in space and relative to the mechanical femoral axis by combining its sagittal and coronal orientation. As long as the imaging visualizes two orthogonal planes, the orientation of an implant can be assessed in 3-D, regardless of the imaging modality.Biomaterials & Tissue Biomechanic
    corecore