20,794 research outputs found
Modelling of human low frequency sound localization acuity demonstrates dominance of spatial variation of interaural time difference and suggests uniform just-noticeable differences in interaural time difference.
Sound source localization is critical to animal survival and for identification of auditory objects. We investigated the acuity with which humans localize low frequency, pure tone sounds using timing differences between the ears. These small differences in time, known as interaural time differences or ITDs, are identified in a manner that allows localization acuity of around 1° at the midline. Acuity, a relative measure of localization ability, displays a non-linear variation as sound sources are positioned more laterally. All species studied localize sounds best at the midline and progressively worse as the sound is located out towards the side. To understand why sound localization displays this variation with azimuthal angle, we took a first-principles, systemic, analytical approach to model localization acuity. We calculated how ITDs vary with sound frequency, head size and sound source location for humans. This allowed us to model ITD variation for previously published experimental acuity data and determine the distribution of just-noticeable differences in ITD. Our results suggest that the best-fit model is one whereby just-noticeable differences in ITDs are identified with uniform or close to uniform sensitivity across the physiological range. We discuss how our results have several implications for neural ITD processing in different species as well as development of the auditory system
Large-Scale Structures Behind the Milky Way from Near-IR Surveys
About 25% of the optical extragalactic sky is obscured by the dust and stars
of our Milky Way. Dynamically important structures might still lie hidden in
this zone. Various approaches are presently being employed to uncover the
galaxy distribution in the Zone of Avoidance (ZOA) but all suffer from
(different) limitations and selection effects.
We investigated the potential of using the DENIS NIR survey for studies of
galaxies behind the obscuration layer of our Milky Way and for mapping the
Galactic extinction. As a pilot study, we recovered DENIS I, J and K band
images of heavily obscured but optically still visible galaxies. We determined
the I, J and K band luminosity functions of galaxies on three DENIS strips that
cross the center of the nearby, low-latitude, rich cluster Abell 3627. The
extinction-corrected I-J and J-K colours of these cluster galaxies compare well
with that of an unobscured cluster. We searched for and identified galaxies at
latitudes where the Milky Way remains fully opaque (|b|
4-5mag) - in a systematic search as well as around positions of galaxies
detected with the blind HI survey of the ZOA currently conducted with the
Multibeam Receiver of the Parkes Radiotelescope.Comment: 12 pages, including 5 PS figures, LaTeX, uses crckapb.sty and
epsf.tex. Better resolved figures available upon request. To appear in
proceedings of the 3rd Euroconference (Meudon, France, June 1997) on ``The
Impact of Near IR Surveys'', Kluwer 199
Comparison of free-living physical activity data obtained from a Fitbit Zip, the Apple iPhone Health app and a modified Bouchard Activity Record
Issue addressed: Physical activity tracking devices have potential to improve public health, but their data needs to be reliable. No study has compared movement data between the Fitbit Zip, Apple iPhone Health app and physical activity records in a community setting over 10 days. Methods: University students aged 18+ years wore both a Fitbit Zip and an iPhone at/near their right waist and completed a modified Bouchard Activity Record (BAR) for 10 days in a free-living setting. Comparisons were made between the Fitbit Zip and iPhone for the number of steps and the distance travelled and between the Fitbit Zip and BAR for the minutes of activity in three different intensities. Results: Eighteen students provided sufficient data for inclusion. There were strong correlations between steps per day (r =.87) and distance travelled (r =.88) between the Fitbit Zips and iPhones. However, the Fitbit Zip measured significantly more steps per day (mean 8437 vs 7303; P ≤.001) and greater distances (mean 5.9 vs 4.9; P ≤.001) than the iPhone. Correlations between the Fitbit Zips and the BARs were moderate for minutes of total (r =.51) and light (r =.40) activity and weak for moderate/fairly active (r =.20) and vigorous/very active (r =.25). Conclusions: There were strong correlations between the physical activity data measured by Fitbit Zips and iPhones, but the iPhone Health app significantly underestimated the number of steps per day taken and the distance travelled when compared to the Fitbit Zip. So what?: Understanding the comparability of accelerometer devices provides useful information for future pragmatic physical activity measurement
Generalized information reuse for optimization under uncertainty with non-sample average estimators
In optimization under uncertainty for engineering design, the behavior of the system outputs due to uncertain inputs needs to be quantified at each optimization iteration, but this can be computationally expensive. Multi-fidelity techniques can significantly reduce the computational cost of Monte Carlo sampling methods for quantifying the effect of uncertain inputs, but existing multi-fidelity techniques in this context apply only to Monte Carlo estimators that can be expressed as a sample average, such as estimators of statistical moments. Information reuse is a particular multi-fidelity method that treats previous optimization iterations as lower-fidelity models. This work generalizes information reuse to be applicable to quantities with non-sample average estimators. The extension makes use of bootstrapping to estimate the error of estimators and the covariance between estimators at different fidelities. Specifically, the horsetail matching metric and quantile function are considered as quantities whose estimators are not sample-averages. In an optimization under uncertainty for an acoustic horn design problem, generalized information reuse demonstrated computational savings of over 60% compared to regular Monte Carlo sampling
Traumatic brain injury: Age at injury influences dementia risk after TBI
Traumatic brain injury (TBI) is increasingly recognized as a risk factor for dementia. New data provide further support for this association and demonstrate the influence of age at injury and injury severity on dementia risk after TBI, revealing that even mild TBI increases dementia risk in those aged ≥65 years
A cross sectional study of water quality from dental unit water lines in dental practices in the West of Scotland
OBJECTIVE: To determine the microbiological quality of water from dental units in a general practice setting and current practice for disinfection of units. DESIGN: A cross-sectional study of the water quality from 40 dental units in 39 general practices and a questionnaire of the disinfection protocols used in those practices. SETTING: NHS practices in primarydental care. SUBJECTS: Thirty-nine general practices from the West of Scotland. METHODS: Water samples were collected on two separate occasions from dental units and analysed for microbiological quality by the total viable count (TVC) method. Water specimens were collected from the triple syringe, high speed outlet, cup filler and surgery tap. Each participating practitioner was asked to complete a questionnaire. Results Microbial contamination was highest from the high speed outlet followed by the triple syringe and cup filler. On average, the TVC counts from the high speed water lines at 37 degrees C and for the high speed lines, triple syringe and cup filler at 22 degrees C were significantly higher than that from the control tap water specimens. The study included units from 11 different manufacturers with ages ranging from under one year to over eight years. The age of the dental unit analysed did not appear to influence the level of microbial contamination. Five of the practices surveyed used disinfectants to clean the dental units but these had no significant effect on the microbiological quality of the water. The majority of dental units (25 out of 40) were never flushed with water between patients. A number of different non-sterile irrigants were used for surgical procedures. CONCLUSION: The microbiological quality of water from dental units in general dental practice is poor compared with that from drinking water sources. Suitable sterile irrigants should be used for surgical procedures in dental practice. Further work is required for pragmatic decontamination regimens of dental unit water lines in a general dental practice setting
Calculations of air-guided modes in photonic crystal fibers using the multipole method
We demonstrate that a combination of multipole and Bloch methods is well suited for calculating the modes of air core photonic crystal fibers. This includes determining the reflective properties of the cladding, which is a prerequisite for the modal calculations. We demonstrate that in the presence of absorption, the modal losses can be substantially smaller than in the corresponding bulk medium. © 2001 Optical Society of America
Evaluation of the efficacy of Alpron disinfectant for dental unit water lines
AIMS: To assess the efficacy of a disinfectant, Alpron, for controlling microbial contamination within dental unit water lines. METHODS: The microbiological quality of water emerging from the triple syringe, high speed handpiece, cup filler and surgery hand wash basin from six dental units was assessed for microbiological total viable counts at 22 degrees C and 37 degrees C before and after treatment with Alpron solutions. RESULTS: The study found that the use of Alpron disinfectant solutions could reduce microbial counts in dental unit water lines to similar levels for drinking water. This effect was maintained in all units for up to six weeks following one course of treatment. In four out of six units the low microbial counts were maintained for 13 weeks. CONCLUSIONS: Disinfectants may have a short term role to play in controlling microbial contamination of dental unit water lines to drinking water quality. However, in the longer term attention must be paid to redesigning dental units to discourage the build up of microbial biofilms
- …