102 research outputs found

    Successful ACL reconstruction with a variant of the pes anserinus

    Get PDF
    An anatomical variant of the pes anserinus encountered during anterior cruciate ligament reconstructive surgery which has not been previously described is discussed. During routine harvesting, the sartorius fascia was incised and the semitendinosus and gracilis tendons were identified. At the distal portion, it was noted that each tendon gave off an additional tendinous slip. The slip from the semitendinosus tendon had attached to the gracilis tendon and vice versa, thereby creating a double pes anserinus. This variant was used to construct the graft, and at 1 year review the patient had returned to full sporting activities with no complications encountered

    Rotational knee laxity: Reliability of a simple measurement device in vivo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Double bundle ACL reconstruction has been demonstrated to decrease rotational knee laxity. However, there is no simple, commercially-available device to measure knee rotation. The investigators developed a simple, non-invasive device to measure knee rotation. In conjunction with a rigid boot to rotate the tibia and a force/moment sensor to allow precise determination of torque about the knee, a magnetic tracking system measures the axial rotation of the tibia with respect to the femur. This device has been shown to have acceptable levels of test re-test reliability to measure knee rotation in cadaveric knees.</p> <p>Methods</p> <p>The objective of this study was to determine reliability of the device in measuring knee rotation of human subjects. Specifically, the intra-tester reliability within a single testing session, test-retest reliability between two testing sessions, and inter-tester reliability were assessed for 11 male subjects with normal knees.</p> <p>Results</p> <p>The 95% confidence interval for rotation was less than 5° for intra-tester, test-retest, and inter-tester reliability, and the standard error of measurement for the differences between left and right knees was found to be less than 3°.</p> <p>Conclusion</p> <p>It was found that the knee rotation measurements obtained with this device have acceptable limits of reliability for clinical use and interpretation.</p

    Olecranon Stress Injury in an Adolescent Overhand Pitcher

    No full text

    Der Wert gestielter Transplantate in der Rekonstruktion veralteter komplexer Kniebandschäden

    No full text
    • …
    corecore