32 research outputs found
Angiotensin type 1 receptor antagonist losartan, reduces MPTP-induced degeneration of dopaminergic neurons in substantia nigra
BACKGROUND: Recent attention has focused on understanding the role of the brain-renin-angiotensin-system (RAS) in stroke and neurodegenerative diseases. Direct evidence of a role for the brain-RAS in Parkinson's disease (PD) comes from studies demonstrating the neuroprotective effect of RAS inhibitors in several neurotoxin based PD models. In this study, we show that an antagonist of the angiotensin II (Ang II) type 1 (AT(1)) receptor, losartan, protects dopaminergic (DA) neurons against 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) toxicity both in primary ventral mesencephalic (VM) cultures as well as in the substantia nigra pars compacta (SNpc) of C57BL/6 mice (Fig. 1). RESULTS: In the presence of exogenous Ang II, losartan reduced MPP(+ )(5 μM) induced DA neuronal loss by 72% in vitro. Mice challenged with MPTP showed a 62% reduction in the number of DA neurons in the SNpc and a 71% decrease in tyrosine hydroxylase (TH) immunostaining of the striatum, whereas daily treatment with losartan lessened MPTP-induced loss of DA neurons to 25% and reduced the decrease in striatal TH(+ )immunostaining to 34% of control. CONCLUSION: Our study demonstrates that the brain-RAS plays an important neuroprotective role in the MPTP model of PD and points to AT(1 )receptor as a potential novel target for neuroprotection
Dendritic spine abnormalities in amyloid precursor protein transgenic mice demonstrated by gene transfer and intravital multiphoton microscopy
Accumulation of amyloid-beta (Aβ) into senile plaques in Alzheimer’s disease (AD) is a hallmark neuropathological feature of the disorder, which likely contributes to alterations in neuronal structure and function. Recent work has revealed changes in neurite architecture associated with plaques and functional changes in cortical signaling in amyloid precursor protein (APP) expressing mouse models of AD. Here we developed a method using gene transfer techniques to introduce GFP into neurons allowing the investigation of neuronal processes in the vicinity of plaques. Multiphoton imaging of GFP-labeled neurons in living Tg2576 APP mice revealed disrupted neurite trajectories and reductions in dendritic spine density compared to age-matched control mice. A profound deficit in spine density (∼50%) extends approximately 20 μm from plaque edges. Importantly, a robust decrement (∼25%) also occurs on dendrites not associated with plaques, suggesting widespread loss of postsynaptic apparatus. Plaques and dendrites remained stable over the course of weeks of imaging. Post-mortem analysis of axonal immunostaining and co-localization of synaptophysin and postsynaptic density 95 (PSD-95) protein staining around plaques indicate a parallel loss of pre- and postsynaptic partners. These results show considerable changes in dendrites and dendritic spines in APP transgenic mice, demonstrating a dramatic synaptotoxic effect of dense core plaques. Decreased spine density will likely contribute to altered neural system function and behavioral impairments observed in Tg2576 mice
Brain ageing in schizophrenia: evidence from 26 international cohorts via the ENIGMA Schizophrenia consortium
Schizophrenia (SZ) is associated with an increased risk of life-long cognitive impairments, age-related chronic disease, and premature mortality. We investigated evidence for advanced brain ageing in adult SZ patients, and whether this was associated with clinical characteristics in a prospective meta-analytic study conducted by the ENIGMA Schizophrenia Working Group. The study included data from 26 cohorts worldwide, with a total of 2803 SZ patients (mean age 34.2 years; range 18-72 years; 67% male) and 2598 healthy controls (mean age 33.8 years, range 18-73 years, 55% male). Brain-predicted age was individually estimated using a model trained on independent data based on 68 measures of cortical thickness and surface area, 7 subcortical volumes, lateral ventricular volumes and total intracranial volume, all derived from T1-weighted brain magnetic resonance imaging (MRI) scans. Deviations from a healthy brain ageing trajectory were assessed by the difference between brain-predicted age and chronological age (brain-predicted age difference [brain-PAD]). On average, SZ patients showed a higher brain-PAD of +3.55 years (95% CI: 2.91, 4.19; I2 = 57.53%) compared to controls, after adjusting for age, sex and site (Cohen's d = 0.48). Among SZ patients, brain-PAD was not associated with specific clinical characteristics (age of onset, duration of illness, symptom severity, or antipsychotic use and dose). This large-scale collaborative study suggests advanced structural brain ageing in SZ. Longitudinal studies of SZ and a range of mental and somatic health outcomes will help to further evaluate the clinical implications of increased brain-PAD and its ability to be influenced by interventions
Large-scale analysis of structural brain asymmetries in schizophrenia via the ENIGMA consortium
Left-right asymmetry is an important organizing feature of the healthy brain that may be altered in schizophrenia, but most studies have used relatively small samples and heterogeneous approaches, resulting in equivocal findings. We carried out the largest case-control study of structural brain asymmetries in schizophrenia, using MRI data from 5,080 affected individuals and 6,015 controls across 46 datasets in the ENIGMA consortium, using a single image analysis protocol. Asymmetry indexes were calculated for global and regional cortical thickness, surface area, and subcortical volume measures. Differences of asymmetry were calculated between affected individuals and controls per dataset, and effect sizes were meta-analyzed across datasets. Small average case-control differences were observed for thickness asymmetries of the rostral anterior cingulate and the middle temporal gyrus, both driven by thinner left-hemispheric cortices in schizophrenia. Analyses of these asymmetries with respect to the use of antipsychotic medication and other clinical variables did not show any significant associations. Assessment of age- and sex-specific effects revealed a stronger average leftward asymmetry of pallidum volume between older cases and controls. Case-control differences in a multivariate context were assessed in a subset of the data (N = 2,029), which revealed that 7% of the variance across all structural asymmetries was explained by case-control status. Subtle case-control differences of brain macro-structural asymmetry may reflect differences at the molecular, cytoarchitectonic or circuit levels that have functional relevance for the disorder. Reduced left middle temporal cortical thickness is consistent with altered left-hemisphere language network organization in schizophrenia
Giant Choroid Plexus Papilloma Resection Utilizing a Transcollation System
BACKGROUND: Large vascular brain tumors pose an exceptional challenge in young children. Choroid plexus papilloma (CPP) is an example of a rare, often large and especially vascular neuroepithelial tumor that most commonly arises in children under 5 yr old. Although patients may be cured by total resection, this tumor poses significant surgical risks and challenges related to intraoperative hemostasis.
OBJECTIVE: To describe our experience using a transcollation system during brain tumor surgery in a child to achieve hemostasis and minimize blood loss while preserving normal brain tissue.
METHODS: A 3-yr-old girl presented following a fall and was found to have a giant CPP growing from the right lateral ventricle. Given the vascularity of the tumor and the low intravascular reserve in a small child, a transcollation device was used to reduce blood loss intraoperatively.
RESULTS: Gross total resection was achieved with approximately 300 mL of blood loss without complications. The patient did well postoperatively. Imaging performed at 3 mo after resection revealed return of normal brain architecture.
CONCLUSION: Transcollation devices appear to be an effective and safe addition to the armamentarium of neurosurgical hemostatic options in intracranial tumor resection in which there is a high risk of intraoperative hemorrhage
Removal of symptomatic craniofacial titanium hardware following craniotomy: Case series and review
AbstractTitanium craniofacial hardware has become commonplace for reconstruction and bone flap fixation following craniotomy. Complications of titanium hardware include palpability, visibility, infection, exposure, pain, and hardware malfunction, which can necessitate hardware removal. We describe three patients who underwent craniofacial reconstruction following craniotomies for trauma with post-operative courses complicated by medically intractable facial pain. All three patients subsequently underwent removal of the symptomatic craniofacial titanium hardware and experienced rapid resolution of their painful parasthesias. Symptomatic plates were found in the region of the frontozygomatic suture or MacCarty keyhole, or in close proximity with the supraorbital nerve. Titanium plates, though relatively safe and low profile, can cause local nerve irritation or neuropathy. Surgeons should be cognizant of the potential complications of titanium craniofacial hardware and locations that are at higher risk for becoming symptomatic necessitating a second surgery for removal
Recommended from our members
Optimization and Long-Term Stability of Micro Flow Sensors for Smart VP Shunts
This paper reports on a systematic study of the flow sensitivity and resolution of micro-flow sensors intended for use in implantable ventricular-peritoneal shunts. The flow sensors utilize ferromagnetic flaps (transducers) whose deflection is detected by ultra-sensitive MTJ sensors (20mV/V/Oe). A working range of 0-40 ml/h was demonstrated at a maximum uncertainty of 4% RMS and a resolution of 0.4 ml/h. Earlier studies on this sensor unveiled significant low-frequency noise (drift) limiting the sensitivity to 1.4 ml/hr. The present study identifies thermal noise as the main source of low-frequency drift. Using thermal compensation it was found that the drift can be reduced below 2 ml per 24-hr. Combining an array of four transducers operating in series, it has been demonstrated that a sensitivity can be increased 10.9 fold. Furthermore, the report examines the long-term structural stability of the sensors and produces a corrosion report suggesting a lifespan of 15 to 55 years.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]