40 research outputs found

    Assessment of pelvic organ prolapse with the Pelvic Inclination Correction System: defining the normal range and threshold to pathology.

    Get PDF
    PURPOSE To define the normal range and threshold values for pathologic prolapse on MRI using the PICS line and assess its correlation with the pubococcygeal line (PCL). METHODS This prospective, IRB-approved study included 20 nulliparous volunteers and 18 prolapse patients (POP-Q Stage ≥ 2). Organ positions (bladder, cervix, anorectal junction) relative to PICS and PCL were measured on dynamic MRI. Differences in organ position were compared. Receiver-operating characteristic (ROC) analysis was performed to identify cutoff values for prolapse using the PICS line. The correlation between PICS and PCL measurements was tested with Spearman's rank correlation. RESULTS In volunteers, median bladder and cervix positions measured to the PICS at rest were - 2.7 cm and - 5.3 cm compared to - 1.9 cm and - 2.7 cm in patients (p < 0.001). During straining, bladder and cervix were at - 0.9 cm and - 3.2 cm in volunteers versus + 2.5 cm and + 2.5 cm in patients (p < 0.001). Correlation was strong for PICS and PCL measurements for all three compartments (δ = 0.883-0.970, p ≤ 0.001). AUCs of PICS for the anterior and middle compartment were 0.98 (95% confidence interval [CI] 0.96-1.00, p < 0.001) and 0.96 (95% CI 0.89-1.00, p < 0.001) for differentiating patients from healthy volunteers. AUC for the posterior compartment was 0.76 (95% CI 0.57-0.96, p = 0.034). CONCLUSION PICS measurements reliably differentiate patients from volunteers in the anterior and middle compartment. Future studies need to identify a reliable threshold for the posterior compartment. PICS and PCL measurements are strongly correlated

    Pelvic organ movements in asymptomatic nulliparous and symptomatic premenopausal women with pelvic organ prolapse in dynamic MRI: a feasibility study comparing midsagittal single-slice with multi-slice sequences

    Full text link
    PURPOSE To compare multi-slice (MS) MRI sequences of the pelvis acquired at rest and straining to dynamic midsagittal single-slice (SS) sequences for the assessment of pelvic organ prolapse (POP). METHODS This IRB-approved prospective single-center feasibility study included 23 premenopausal symptomatic patients with POP and 22 asymptomatic nulliparous volunteers. MRI of the pelvis at rest and straining was performed with midsagittal SS and MS sequences. Straining effort, visibility of organs and POP grade were scored on both. Organ points (bladder, cervix, anorectum) were measured. Differences between SS and MS sequences were compared with Wilcoxon test. RESULTS Straining effort was good in 84.4% on SS and in 64.4% on MS sequences (p = 0.003). Organ points were always visible on MS sequences, whereas the cervix was not fully visible in 31.1-33.3% on SS sequences. At rest, there were no statistically significant differences of organ point measurements between SS and MS sequences in symptomatic patients. At straining, positions of bladder, cervix, and anorectum were + 1.1 cm (± 1.8 cm), - 0.7 cm (± 2.9 cm), and + 0.7 cm (± 1.3 cm) on SS and + 0.4 mm (± 1.7 cm), - 1.4 cm (± 2.6 cm), and + 0.4 cm (± 1.3 cm) on MS sequences (p < 0.05). Only 2 cases of higher-grade POP were missed on MS sequences (both with poor straining effort). CONCLUSION MS sequences increase the visibility of organ points compared to SS sequences. Dynamic MS sequences can depict POP if images are acquired with sufficient straining effort. Further work is needed to optimize the depiction of the maximum straining effort with MS sequences

    Fully automated deep learning powered calcium scoring in patients undergoing myocardial perfusion imaging

    Full text link
    BACKGROUND To assess the accuracy of fully automated deep learning (DL) based coronary artery calcium scoring (CACS) from non-contrast computed tomography (CT) as acquired for attenuation correction (AC) of cardiac single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI). METHODS AND RESULTS Patients were enrolled in this study as part of a larger prospective study (NCT03637231). In this study, 56 Patients who underwent cardiac SPECT-MPI due to suspected coronary artery disease (CAD) were prospectively enrolled. All patients underwent non-contrast CT for AC of SPECT-MPI twice. CACS was manually assessed (serving as standard of reference) on both CT datasets (n = 112) and by a cloud-based DL tool. The agreement in CAC scores and CAC score risk categories was quantified. For the 112 scans included in the analysis, interscore agreement between the CAC scores of the standard of reference and the DL tool was 0.986. The agreement in risk categories was 0.977 with a reclassification rate of 3.6%. Heart rate, image noise, body mass index (BMI), and scan did not significantly impact (p=0.09 - p=0.76) absolute percentage difference in CAC scores. CONCLUSION A DL tool enables a fully automated and accurate estimation of CAC scores in patients undergoing non-contrast CT for AC of SPECT-MPI

    Follow-up PET/CT of alveolar echinococcosis: Comparison of metabolic activity and immunodiagnostic testing

    Full text link
    PURPOSE To investigate the potential role of follow-up 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in therapy control of inoperable patients with alveolar echinococcosis. MATERIALS AND METHODS In this single-center retrospective cohort study, 48 PET/CT of 16 patients with confirmed alveolar echinococcosis were analysed. FDG-uptake of the most active echinococcosis manifestation was measured (i.e., maximum standardized uptake value (SUVmax) and in relation to background activity in normal liver tissue (SUVratio)) and compared to immunodiagnostic testing. For clinical patient follow-up, patient demographics, laboratory data, including E. granulosus hydatid fluid (EgHF) antibody units (AU) as well as clinical and treatment information were assessed for all patients at the time of PET/CT, and at the last recorded clinical visit. RESULTS Metabolic activity of PET/CT measured in the echinococcosis manifestation was significantly correlated with EgHF AU (p < 0.001). The differences in metabolic activity of echinococcosis manifestations between two consecutive PET/CT examinations of the same patient and differences in EgHF AU in the respective time intervals displayed a significant positive correlation (p = 0.01). A trend for a more rapid decline in SUVratio liver over time was found in patients who stopped benzimidazole therapy versus patients who did not stop therapy (p = 0.059). CONCLUSION In inoperable patients with alveolar echinococcosis, the course of metabolic activity in follow-up PET/CT is associated to the course EgHF antibody levels. Both parameters may potentially be used to evaluate the course of the disease and potentially predict the duration of benzimidazole therapy

    Automated F18-FDG PET/CT image quality assessment using deep neural networks on a latest 6-ring digital detector system

    Get PDF
    To evaluate whether a machine learning classifier can evaluate image quality of maximum intensity projection (MIP) images from F18-FDG-PET scans. A total of 400 MIP images from F18-FDG-PET with simulated decreasing acquisition time (120 s, 90 s, 60 s, 30 s and 15 s per bed-position) using block sequential regularized expectation maximization (BSREM) with a beta-value of 450 and 600 were created. A machine learning classifier was fed with 283 images rated "sufficient image quality" and 117 images rated "insufficient image quality". The classification performance of the machine learning classifier was assessed by calculating sensitivity, specificity, and area under the receiver operating characteristics curve (AUC) using reader-based classification as the target. Classification performance of the machine learning classifier was AUC 0.978 for BSREM beta 450 and 0.967 for BSREM beta 600. The algorithm showed a sensitivity of 89% and 94% and a specificity of 94% and 94% for the reconstruction BSREM 450 and 600, respectively. Automated assessment of image quality from F18-FDG-PET images using a machine learning classifier provides equivalent performance to manual assessment by experienced radiologists

    Impact of Bayesian penalized likelihood reconstruction on quantitative and qualitative aspects for pulmonary nodule detection in digital 2-[18F]FDG-PET/CT

    Full text link
    To evaluate the impact of block sequential regularized expectation maximization (BSREM) reconstruction on quantitative and qualitative aspects of 2-[18F]FDG-avid pulmonary nodules compared to conventional ordered subset expectation maximization (OSEM) reconstruction method. Ninety-one patients with 144 2-[18F]FDG-avid pulmonary nodules (all ≤ 20 mm) undergoing PET/CT for oncological (re-)staging were retrospectively included. Quantitative parameters in BSREM and OSEM (including point spread function modelling) were measured, including maximum standardized uptake value (SUVmax). Nodule conspicuity in BSREM and OSEM images was evaluated by two readers. Wilcoxon matched pairs signed-rank test was used to compare quantitative and qualitative parameters in BSREM and OSEM. Pulmonary nodule SUVmax was significantly higher in BSREM images compared to OSEM images [BSREM 5.4 (1.2–20.7), OSEM 3.6 (0.7–17.4); p = 0.0001]. In a size-based analysis, the relative increase in SUVmax was more pronounced in smaller nodules (≤ 7 mm) as compared to larger nodules (8–10 mm, or > 10 mm). Lesion conspicuity was higher in BSREM than in OSEM (p < 0.0001). BSREM reconstruction results in a significant increase in SUVmax and a significantly improved conspicuity of small 2-[18F]FDG-avid pulmonary nodules compared to OSEM reconstruction. Digital 2-[18F]FDG-PET/CT reading may be enhanced with BSREM as small lesion conspicuity is improved

    Prediction of pelvic lymph node metastases and PSMA PET positive pelvic lymph nodes with multiparametric MRI and clinical information in primary staging of prostate cancer

    Full text link
    PURPOSE To compare the accuracy of multiparametric MRI (mpMRI), 68^{68}Ga-PSMA PET and the Briganti 2019 nomogram in the prediction of metastatic pelvic lymph nodes (PLN) in prostate cancer, to assess the accuracy of mpMRI and the Briganti nomogram in prediction of PET positive PLN and to investigate the added value of quantitative mpMRI parameters to the Briganti nomogram. METHOD This retrospective IRB-approved study included 41 patients with prostate cancer undergoing mpMRI and 68^{68}Ga-PSMA PET/CT or MR prior to prostatectomy and pelvic lymph node dissection. A board-certified radiologist assessed the index lesion on diffusion-weighted (Apparent Diffusion Coefficient, ADC; mean/volume), T2-weighted (capsular contact length, lesion volume/maximal diameters) and contrast-enhanced (iAUC, kep_{ep}, Ktrans^{trans}, ve_{e}) sequences. The probability for metastatic pelvic lymph nodes was calculated using the Briganti 2019 nomogram. PET examinations were evaluated by two board-certified nuclear medicine physicians. RESULTS The Briganti 2019 nomogram performed superiorly (AUC: 0.89) compared to quantitative mpMRI parameters (AUCs: 0.47-0.73) and 68^{68}Ga-PSMA-11 PET (AUC: 0.82) in the prediction of PLN metastases and superiorly (AUC: 0.77) in the prediction of PSMA PET positive PLN compared to MRI parameters (AUCs: 0.49-0.73). The addition of mean ADC and ADC volume from mpMRI improved the Briganti model by a fraction of new information of 0.21. CONCLUSIONS The Briganti 2019 nomogram performed superiorly in the prediction of metastatic and PSMA PET positive PLN, but the addition of parameters from mpMRI can further improve its accuracy. The combined model could be used to stratify patients requiring ePLND or PSMA PET

    Characterization of hypermetabolic lymph nodes after SARS-CoV-2 vaccination using PET-CT derived node-RADS, in patients with melanoma

    Get PDF
    This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18^{18}F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18^{18}F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18^{18}F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18^{18}F]-FDG PET/CT and SARS-CoV-2 vaccination

    Frequency and temporal evolution of COVID-19 vaccination rate among oncological patients undergoing 18F-FDG-PET

    Full text link
    Purpose: To evaluate the temporal evolution of vaccination against COVID-19 in a Swiss oncological cohort. Methods: History of complete vaccination (i.e. at least two vaccine doses) against COVID-19 of patients undergoing oncological 18F-FDG PET/CT between February and September 2021 (n = 2613) was taken. Vaccination rate was compared with age-matched national data from the Swiss Federal Office of Public Health. Subgroup differences in temporal evolution of vaccination rate were analyzed by fitting a generalized linear model and determined by significant interaction between, sex, oncological diagnosis, and month of examination. Results: Rate of complete vaccination against COVID-19 steadily increased and reached 81 % in September 2021. The fraction of vaccinated patients in the oncological cohort was higher in the beginning and approached the fraction in the age-matched general Swiss population at the end of the study period. Month of exam (p < 0.001) was the only significant predictor of the vaccination rate. Conclusion: Vaccination rate against COVID-19 in a Swiss oncological cohort increased steadily from February to September 2021. Compared to the age-matched general population it was higher in the beginning and similar by the end of the study period. Ethics approval: Trial registration: BASEC 2021-00444, Ethikkommission Zürich (Cantonal Ethics Committee Zurich), Switzerland, registered February 24th 2021. Keywords: COVID-19; Cancer; Fluordeoxyglucose; Oncological Imaging; Vaccinatio

    A third of the radiotracer dose: two decades of progress in pediatric [18^{18}F]fluorodeoxyglucose PET/CT and PET/MR imaging

    Full text link
    OBJECTIVES To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3^{3} volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation
    corecore