    Maximal care considerations when treating patients with end-stage heart failure: ethical and procedural quandaries in management of the very sick

    Get PDF
    Deciding who should receive maximal technological treatment options and who should not represents an ethical, moral, psychological and medico-legal challenge for health care providers. Especially in patients with chronic heart failure, the ethical and medico-legal issues associated with providing maximal possible care or withholding the same are coming to the forefront. Procedures, such as cardiac transplantation, have strict criteria for adequate candidacy. These criteria for subsequent listing are based on clinical outcome data but also reflect the reality of organ shortage. Lack of compliance and non-adherence to lifestyle changes represent relative contraindications to heart transplant candidacy. Mechanical circulatory support therapy using ventricular assist devices is becoming a more prominent therapeutic option for patients with end-stage heart failure who are not candidates for transplantation, which also requires strict criteria to enable beneficial outcome for the patient. Physicians need to critically reflect that in many cases, the patient’s best interest might not always mean pursuing maximal technological options available. This article reflects on the multitude of critical issues that health care providers have to face while caring for patients with end-stage heart failure

    Heart transplantation using bivalirudin as anticoagulant

    No full text

    Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

    No full text
    OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass
    corecore