79 research outputs found

    Bronchial Thermoplasty

    Get PDF

    Biopsy frequency and complications among lung cancer patients in the United States

    Get PDF
    Objective: This study aimed to describe the frequency and distribution of biopsy procedures for patients diagnosed and treated for primary lung cancer. Study design: Retrospective cohort study within an administrative database. Materials & methods: This observational study used data from the IBM MarketScan Results: The total number of lung biopsies performed among eligible subjects was 32,814; an average of 1.7 biopsies per patient. Bronchoscopy and percutaneous approaches accounted for 95% of all procedures. Complication rates by procedure are remarkably similar irrespective of biopsy frequency. Conclusion: Nearly half (46%) of patients in this population experienced multiple biopsies prior to diagnosis. Further, biopsy choice or sequence in patients receiving multiple procedures was unpredictable

    One-session bilateral sequential whole lung lavage (OSBSWLL) for the management of pulmonary alveolar proteinosis

    Get PDF
    BACKGROUND: Whole Lung Lavage (WLL) has been an important part in the management of Pulmonary Alveolar Proteinosis (PAP) since it improves radiologic and clinical parameters. Bilateral WLL is usually performed in two sessions on different days. Few case reports have described one-session bilateral sequential lung lavage (OSBSWLL), and none have described ambulatory management (same-day discharge). METHODS: Demographic characteristics, physiologic parameters, procedure details and outcomes were retrospectively collected on consecutive patients who underwent OSBSWLL for PAP following an ambulatory protocol stablished in our institution. RESULTS: A total of 13 patients underwent 30 OSBSWLL (61.5% male; mean age 40). The mean SpO2 was 90% (IQR 9) and 94% (IQR 6), before and after OSBSWLL respectively. In 63.3% of cases, patients were discharged home the same day of procedure. Only in two cases (6.6%), patients required post-procedure prolonged mechanical ventilation (\u3e 4 h) due to persistent hypoxia. CONCLUSIONS: OSBSWLL can be performed with same-day discharge

    Diphenhydramine as an adjunct to conscious sedation in bronchoscopy

    Get PDF
    Intravenous benzodiazepines are commonly used to achieve conscious sedation in outpatient bronchoscopy. Though effective, dose-dependent-adverse events may be encountered with the use of these sedatives. Diphenhydramine, a hypnotic, is sometimes used as an adjunctive agent in bronchoscopy to decrease sedative usage. However, data to support this practice is lacking. Our goal was to determine if adjunctive diphenhydramine significantly decreases doses of benzodiazepine in outpatient bronchoscopy. METHODS: We conducted a single-center retrospective analysis of all outpatient bronchoscopies from November 2013 to February 2016. Subjects included were those who each had two bronchoscopies: no diphenhydramine used (control) versus diphenhydramine used (intervention). The procedure time, total doses of midazolam and opiates (in morphine equivalence) for each procedure were collected. A multiple regression analysis was used to compare differences between bronchoscopy groups in midazolam and opiate use. RESULTS: Of 1164 patients with greater than 1 outpatient bronchoscopies, 61 unique subjects (female 56%) fulfilled the primary inclusion criteria thus resulting to 122 procedures. Mean body mass index was 32 kg/m2. Procedure time was 22.9 ± 16 mins in diphenhydramine group and 23.2 ± 17.8 mins in control group. Mean morphine equivalents administered was 5.6 ± 2.6 mg in diphenhydramine group and 6.2 ± 2.4 mg in control group. Mean midazolam use was 8.4 ± 3.2 mg in diphenhydramine group and 10.2 ± 3.8 mg in control group (difference: -1.795, p-value = 0.005). The mean dose of diphenhydramine used was 38.32 ± 15.12 mg. In a multivariate model, mean midazolam use remained less in the diphenhydramine group after adjusting for procedure time and morphine equivalents, (difference -1.28 mg, p-value = 0.005). CONCLUSIONS: Intravenous administration of diphenhydramine during outpatient bronchoscopy reduces midazolam usage, however, the absolute amount of dose reduction may not be clinically significant

    Robotic bronchoscopy for peripheral pulmonary lesions: A multicenter pilot and feasibility study (BENEFIT)

    Get PDF
    BACKGROUND: The diagnosis of peripheral pulmonary lesions (PPL) continues to present clinical challenges. Despite extensive experience with guided bronchoscopy, the diagnostic yield has not improved significantly. Robotic-assisted bronchoscopic platforms have been developed potentially to improve the diagnostic yield for PPL. Presently, limited data exist that evaluate the performance of robotic systems in live human subjects. RESEARCH QUESTION: What is the safety and feasibility of robotic-assisted bronchoscopy in patients with PPLs? STUDY DESIGN AND METHODS: This was a prospective, multicenter pilot and feasibility study that used a robotic bronchoscopic system with a mother-daughter configuration in patients with PPL 1 to 5 cm in size. The primary end points were successful lesion localization with the use of radial probe endobronchial ultrasound (R-EBUS) imaging and incidence of procedure related adverse events. Robotic bronchoscopy was performed in patients with the use of direct visualization, electromagnetic navigation, and fluoroscopy. After the use of R-EBUS imaging, transbronchial needle aspiration was performed. Rapid on-site evaluation (ROSE) was used on all cases. Transbronchial needle aspiration alone was sufficient when ROSE was diagnostic; when ROSE was not diagnostic, transbronchial biopsy was performed with the use of the robotic platform, followed by conventional guided bronchoscopic approaches at the discretion of the investigator. RESULTS: Fifty-five patients were enrolled at five centers. One patient withdrew consent, which left 54 patients for data analysis. Median lesion size was 23 mm (interquartile range, 15 to 29 mm). R-EBUS images were available in 53 of 54 cases. Lesion localization was successful in 51 of 53 patients (96.2%). Pneumothorax was reported in two of 54 of the cases (3.7%); tube thoracostomy was required in one of the cases (1.9 %). No additional adverse events occurred. INTERPRETATION: This is the first, prospective, multicenter study of robotic bronchoscopy in patients with PPLs. Successful lesion localization was achieved in 96.2% of cases, with an adverse event rate comparable with conventional bronchoscopic procedures. Additional large prospective studies are warranted to evaluate procedure characteristics, such as diagnostic yield. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT03727425; URL: www.clinicaltrials.gov

    Costs of Biopsy and Complications in Patients with Lung Cancer

    Get PDF
    PURPOSE: To describe the distribution of diagnostic procedures, rates of complications, and total cost of biopsies for patients with lung cancer. PATIENTS AND METHODS: Observational study using data from IBM Marketscan(®) Databases for continuously insured adult patients with a primary lung cancer diagnosis and treatment between July 2013 and June 2017. Costs of lung cancer diagnosis covered 6 months prior to index biopsy through treatment. Costs of chest CT scans, biopsy, and post-procedural complications were estimated from total payments. Costs of biopsies incidental to inpatient admissions were estimated by comparable outpatient biopsies. RESULTS: The database included 22,870 patients who had a total of 37,160 biopsies, of which 16,009 (43.1%) were percutaneous, 14,997 (40.4%) bronchoscopic, 4072 (11.0%) surgical and 2082 (5.6%) mediastinoscopic. Multiple biopsies were performed on 41.9% of patients. The most common complications among patients receiving only one type of biopsy were pneumothorax (1304 patients, 8.4%), bleeding (744 patients, 4.8%) and intubation (400 patients, 2.6%). However, most complications did not require interventions that would add to costs. Median total costs were highest for inpatient surgical biopsies (29,988)andlowestforoutpatientpercutaneousbiopsies(29,988) and lowest for outpatient percutaneous biopsies (1028). Repeat biopsies of the same type increased costs by 40-80%. Complications account for 13% of total costs. CONCLUSION: Costs of biopsies to confirm lung cancer diagnosis vary substantially by type of biopsy and setting. Multiple biopsies, inpatient procedures and complications result in higher costs

    Understanding the patient journey to diagnosis of lung cancer

    Get PDF
    OBJECTIVE: This research describes the clinical pathway and characteristics of two cohorts of patients. The first cohort consists of patients with a confirmed diagnosis of lung cancer while the second consists of patients with a solitary pulmonary nodule (SPN) and no evidence of lung cancer. Linked data from an electronic medical record and the Louisiana Tumor Registry were used in this investigation. MATERIALS AND METHODS: REACHnet is one of 9 clinical research networks (CRNs) in PCORnet®, the National Patient-Centered Clinical Research Network and includes electronic health records for over 8 million patients from multiple partner health systems. Data from Ochsner Health System and Tulane Medical Center were linked to Louisiana Tumor Registry (LTR), a statewide population-based cancer registry, for analysis of patient\u27s clinical pathways between July 2013 and 2017. Patient characteristics and health services utilization rates by cancer stage were reported as frequency distributions. The Kaplan-Meier product limit method was used to estimate the time from index date to diagnosis by stage in lung cancer cohort. RESULTS: A total of 30,559 potentially eligible patients were identified and 2929 (9.58%) had primary lung cancer. Of these, 1496 (51.1%) were documented in LTR and their clinical pathway to diagnosis was further studied. Time to diagnosis varied significantly by cancer stage. A total of 24,140 patients with an SPN were identified in REACHnet and 15,978 (66.6%) had documented follow up care for 1 year. 1612 (10%) had no evidence of any work up for their SPN. The remaining 14,366 had some evidence of follow up, primarily office visits and additional chest imaging. CONCLUSION: In both cohorts multiple biopsies were evident in the clinical pathway. Despite clinical workup, 70% of patients in the lung cancer cohort had stage III or IV disease. In the SPN cohort, only 66% were identified as receiving a diagnostic work-up

    Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ionâ„¢ Endoluminal System

    Get PDF
    BACKGROUND: Traditional bronchoscopy provides limited approach to peripheral nodules. Shape-sensing robotic-assisted bronchoscopy (SSRAB, Ion™ Endoluminal System) is a new tool for minimally invasive peripheral nodule biopsy. We sought to answer the research question: Does SSRAB facilitate sampling of pulmonary nodules during bronchoscopists\u27 initial experience? METHODS: The lead-in stage of a multicenter, single-arm, prospective evaluation of the Ion Endoluminal System (PRECIsE) is described. Enrolled subjects ≥ 18 years old had recent computed tomography evidence of one or more solid or semi-solid pulmonary nodules ≥ 1.0 to ≤ 3.5 cm in greatest dimension and in any part of the lung. Subjects were followed at 10- and 30-days post-procedure. This stage provided investigators and staff their first human experience with the SSRAB system; safety and procedure outcomes were analyzed descriptively. Neither diagnostic yield nor sensitivity for malignancy were assessed in this stage. Categorical variables are summarized by percentage; continuous variables are summarized by median/interquartile range (IQR). RESULTS: Sixty subjects were enrolled across 6 hospitals; 67 nodules were targeted for biopsy. Median axial, coronal and sagittal diameters were \u3c 18 mm with a largest cardinal diameter of 20.0 mm. Most nodules were extraluminal and distance from the outer edge of the nodule to the pleura or nearest fissure was 4.0 mm (IQR: 0.0, 15.0). Median bronchial generation count to the target location was 7.0 (IQR: 6.0, 8.0). Procedure duration (catheter-in to catheter-out) was 66.5 min (IQR: 50.0, 85.5). Distance from the catheter tip to the closest edge of the virtual nodule was 7.0 mm (IQR: 2.0, 12.0). Biopsy completion was 97.0%. No pneumothorax or airway bleeding of any grade was reported. CONCLUSIONS: Bronchoscopists leveraged the Ion SSRAB\u27s functionality to drive the catheter safely in close proximity of the virtual target and to obtain biopsies. This initial, multicenter experience is encouraging, suggesting that SSRAB may play a role in the management of pulmonary nodules. Clinical Trial Registration identifier and date NCT03893539; 28/03/2019

    The Influence of Dosimetric Parameters on Quality of Life for Early Stage Non-small Cell Lung Cancer Patients Treated with Stereotactic Body Radiation Therapy

    Get PDF
    Background: Lung stereotactic body radiotherapy (SBRT) has become a standard treatment option for early stage non-small cell lung cancer (NSCLC) patients who are medically inoperable. The influence of radiation dose/volume parameters on quality of life is not known. Our hypothesis is that clinically meaningful declines in quality of life over time will be associated with increased radiation lung dose/volume parameters. Objectives: To investigate clinical toxicity and quality of life (QOL) outcomes of stage I NSCLC patients after SBRT as a function of radiation dose/volume parameters. Methods: In this IRB-approved study, 55 stage I NSCLC patients who received SBRT (12 Gy x 4) and completed QOL forms were analyzed. Clinical symptoms and QOL were measured at baseline and at 3, 6, 12, 18, 24, and 36 months post-SBRT. Clinical toxicity was graded using the common terminology criteria for adverse effects (CTCAE v4.0). Quality of life was followed using the validated Functional Assessment of Cancer Therapy-Trial Outcome Index (FACT-TOI) instrument. Dosimetric parameters, including the mean lung radiation dose (MLD), and the volume of normal lung receiving \u3e 5, 10, 13 or 20 Gy (V5, V10, V13, and V20) were measured from the radiation treatment plan. Student\u27s t-test and Pearson correlation analyses were used to examine the relationships between radiation lung metrics and clinically meaningful changes in QOL and/or clinical toxicities. Kaplan-Meier method was used to estimate rates of local control (LC), disease free survival (DFS), and overall survival (OS). Results: With a median follow-up of 24 months, the 3 year LC, DFS, and OS were 93%, 65% and 84%, respectively, with 5.5% grade 3 toxicity and no grade 4 or 5 toxicities. Clinically meaningful declines in patient reported QOL (FACT-TOI, lung cancer subscale, physical well-being, and/or functional well-being) post-treatment significantly correlated with increased dosimetric parameters, such as V10, V13, and V20. Conclusions: While lung SBRT is associated with excellent LC and minimal clinical toxicity for early stage NSCLC, clinically meaningful declines in QOL significantly correlated with increasing lung dose/volume parameters. This suggests that further improvements in the techniques of lung SBRT have the potential to further enhance patients\u27 QOL following this treatment
    • …
    corecore