12 research outputs found

    Factors influencing endoscopic estimation of colon polyp size in a colon model

    Get PDF
    Background/Aims Colorectal polyps are removed to prevent progression to colorectal cancer. Polyp size is an important factor for risk stratification of malignant transformation. Endoscopic size estimation correlates poorly with pathological reports and several factors have been suggested to influence size estimation. We aimed to gain insight into the factors influencing endoscopic polyp size estimation. Methods Images of polyps in an artificial model were obtained at 1, 3, and 5 cm from the colonoscope’s tip. Participants were asked to estimate the diameter and volume of each polyp. Results Fifteen endoscopists from three large-volume centers participated in this study. With an intraclass correlation coefficient of 0.66 (95% confidence interval [CI], 0.62–0.71) for diameter and 0.56 (95% CI, 0.50–0.62) for volume. Polyp size estimated at 3 cm from the colonoscope’s tip yielded the best results. A lower distance between the tip and the polyp was associated with a larger estimated polyp size. Conclusions Correct endoscopic estimation of polyp size remains challenging. This finding can affect size estimation skills and future training programs for endoscopists

    Geometrical changes in Anaconda endograft limbs after endovascular aneurysm repair: A potential predictor for limb occlusion

    Get PDF
    The emergence of limb occlusion after endovascular aneurysm repair may be related to the conformational changes between the endograft structure and the patient's anatomy. This study analyzed detailed geometric changes of Anaconda endograft (Terumo Aortic, Inchinnan, Scotland, UK) limbs during the cardiac cycle–based computed tomography on serial imaging after graft implantation. Fifteen patients (mean age 72.8 ± 3.7 years; 14 men) underwent postoperative electrocardiogram-gated computed tomography scans according to a prospective study design between April 2014 and May 2017. Changes in curvature, length of the limbs, and distances between successive stent rings (inter-ring distance) of the endograft limbs during a 2-year follow-up period were quantified using meticulous image processing methods involving image registration, centerline extraction, and model-based stent-ring segmentation. From discharge to 24 months, mean curvature increased significantly by 9.6 m–1 (standard deviation [SD], 11.1 m–1; 95% confidence interval [CI], 3.4 to 15.8 m–1; P =.002) for the right limbs and by 6.1 m–1 (SD 9.4 m–1; 95% CI, 0.8 to 11.5 m–1; P =.21) for the left limbs. The length of the right limbs decreased significantly, by 9.5 mm (SD 7.6 mm; 95% CI, 3.5 to 15.6 mm; P =.002); the length of the left limbs decreased by 10.1 mm (SD 5.1 mm; 95% CI, 5.9 to 14.2 mm; P <.001). The minimal inter-ring distance decreased by 0.36 mm (SD 0.26 mm; 95% CI, 0.17 to 0.55 mm; P <.001) for the right limbs and 0.35 mm (SD 0.19 mm; 95% CI, 0.21 to 0.49 mm; P <.001) for the left limbs. Cardiac pulsatility–induced changes in curvature, limb length, and inter-ring distance were negligible (2%, 0.3% and 0.3%, respectively). Changes in the geometry of the Anaconda endograft limbs after endovascular aortic aneurysm repair were observed during a 2-year follow-up manifest as an increase in curvature, shortening of the stent-graft limbs, and a corresponding decrease in inter-ring distance. These stent-graft conformational changes could result in inward folding of the graft fabric, which may relate to the emergence of limb occlusion. Further investigation of these metrics in a larger cohort involving patients with and without occlusions may allow determination of their predictive value

    In Vivo Quantification of Cardiac-Pulsatility-Induced Motion Before and After Double-Branched Endovascular Aortic Arch Repair

    Get PDF
    The Relay®Branch stent-graft (Terumo Aortic, Sunrise, FL, USA) offers a custom-made endovascular solution for complex aortic arch pathologies. In this technical note, a modified electrocardiography (ECG)-gated computed tomography (CT)-based algorithm was applied to quantify cardiac-pulsatility-induced changes of the aortic arch geometry and motion before and after double-branched endovascular repair (bTEVAR) of an aortic arch aneurysm. This software algorithm has the potential to provide novel and clinically relevant insights in the influence of bTEVAR on aortic anatomy, arterial compliance, and stent-graft dynamics

    Geometrical Changes of the Aorta as Predictors for Thromboembolic Events After EVAR With the Anaconda Stent-Graft

    Get PDF
    Purpose: Thromboembolic events (TE), including limb graft occlusion (LGO) and distal limb embolization (DLE), are common complications after endovascular aneurysm repair (EVAR). The aim of this study was to find predictors for TE in patients treated with the Anaconda stent-graft for infrarenal aneurysms. Materials and Methods: Geometrical and anatomical variables were retrospectively analyzed in a consecutive Anaconda cohort. Pre- and postoperative CT scans were used to derive geometrical parameters length, curvature, torsion, and tortuosity index (TI) from the center lumen lines (CLLs). Limb characteristics, pre-to-post EVAR and mid-term-follow-up changes in the parameters were evaluated for their predictive value for TE. Results: Eighty-four patients (mean age 74±8.3 years, 74 men) were enrolled. The risk of TE was lowered with pre-to-post implant decreasing TI (steps of 0.05: OR: 1.30, 95% CI: 1.01-1.66, p=0.04), pre-to-post implant decreasing mean curvature (OR: 1.08, 95% CI: 1.01-1.16, p=0.03), and a larger degree of circumferential common iliac artery (CIA) calcification (OR: 0.98, 95% CI: 0.97-1.00, p=0.03). The only LGO predictor was the caudal relocation of maximal curvature after EVAR (OR: 1.01, 95% CI: 1.00-1.01, p=0.04). Preventors of DLE were CIA diameter (OR: 0.87, 95% CI: 0.76-0.99, p=0.04), circumferential CIA calcification (OR: 0.97, 95% CI: 0.95-1.00, p=0.03), mean and maximal curvature of the preoperative aortoiliac trajectory (OR: 0.86, 95% CI: 0.79-0.94, p<0.01 and OR: 0.97, 95% CI: 0.95-1.00, p=0.03, respectively) and pre-to-postoperative decrease in mean curvature (OR: 1.11, 95% CI: 1.02-1.21, p=0.02). Midterm TE predictors were length (OR: 0.95, 95% CI: 0.89-1.01, p=0.08) and torsion maximum location (OR: 1.01, 95% CI: 0.99-1.01, p=0.10). Conclusion: The present study confirms that treatment of infrarenal AAA with an Anaconda stent-graft is related to a relatively high TE rate which decreases with a pre-to-postoperative reduction in curvature and TI, and a larger degree of circumferential CIA calcification. In other words, more aortoiliac straightening and more circumferential CIA calcification may prevent TE development after EVAR with this stent-graft

    Differences in Cardiac-Pulsatility-Induced Displacement and Geometry Changes between the Cook ZBIS and Gore IBE: Postoperative Comparison Using ECG-Gated CTA Scans

    Get PDF
    To what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE). All patients underwent a retrospective electrocardiogram (ECG)-gated computed tomographic angiography (CTA) during follow-up. Cardiac-pulsatility-induced displacement was quantified for the following locations: (neo) bifurcation of the aorta, IBD flow divider, distal markers of the internal iliac artery (IIA) component and first IIA bifurcation. Geometrical parameters (length, tortuosity index, curvature and torsion) were quantified over centerlines. Displacement was more pronounced for the IBE than the ZBIS, e.g., craniocaudal displacement of 0.91 mm (0.91–1.13 mm) vs. 0.57 mm (0.40–0.75 mm, p = 0.004), respectively. The IBDs demonstrated similar geometrical parameters in the neo-common iliac artery and distal IIA, except for the larger dynamic curvature and torsion of the distal IIA in IBEs. The IBEs showed more dynamic length and curvature change compared to the ZBIS in the stented IIA. The IIA trajectory showed more pronounced deformation during the cardiac cycle after placement of an IBE than a ZBIS, suggesting the IBE is more conformable than the ZBIS

    Differences in Cardiac-Pulsatility-Induced Displacement and Geometry Changes between the Cook ZBIS and Gore IBE: Postoperative Comparison Using ECG-Gated CTA Scans

    No full text
    To what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE). All patients underwent a retrospective electrocardiogram (ECG)-gated computed tomographic angiography (CTA) during follow-up. Cardiac-pulsatility-induced displacement was quantified for the following locations: (neo) bifurcation of the aorta, IBD flow divider, distal markers of the internal iliac artery (IIA) component and first IIA bifurcation. Geometrical parameters (length, tortuosity index, curvature and torsion) were quantified over centerlines. Displacement was more pronounced for the IBE than the ZBIS, e.g., craniocaudal displacement of 0.91 mm (0.91&ndash;1.13 mm) vs. 0.57 mm (0.40&ndash;0.75 mm, p = 0.004), respectively. The IBDs demonstrated similar geometrical parameters in the neo-common iliac artery and distal IIA, except for the larger dynamic curvature and torsion of the distal IIA in IBEs. The IBEs showed more dynamic length and curvature change compared to the ZBIS in the stented IIA. The IIA trajectory showed more pronounced deformation during the cardiac cycle after placement of an IBE than a ZBIS, suggesting the IBE is more conformable than the ZBIS