Hemispherical and minimally invasive total hip reamers: a biomechanical analysis of use and design
Background The purpose of this study was to determine the accuracy of used and new reamer systems for both hemispherical and minimally invasive (MIS) acetabular reamers. Methods New and used hemispherical and MIS acetabular reamers were tested on a computer numerical control machine to ream holes in special machinable wax blocks. Each reamer was tested 3 times in sizes 48 mm through 55 mm. Results The used reamers significantly underreamed by an average of 1.33 vs 0.28 mm compared to new reamers. Hemispherical reamers underreamed significantly more than MIS reamers, with a mean difference of 0.99 vs 0.63 mm, respectively. Used hemispherical reamers showed an average ream undersize of 1.61 vs 0.37 mm, compared to new hemispherical reamers. Used MIS reamers showed an average ream undersize of 1.06 vs 0.20 mm for the new MIS reamers. Conclusions For a manufacturer-specified reamer size, both hemispherical and MIS reamers underream. Newer reamers cut truer to expected values than used ones. MIS reamers performed more accurately than hemispherical reamers. Used acetabular reamer systems may negatively affect the sizing of prepared acetabular beds; therefore, awareness of this potential inaccuracy should be considered when performing total hip arthroplasty. © 2016 The Author
Intraoperative Periprosthetic Femur Fracture: A Biomechanical Analysis of Cerclage Fixation.
Intraoperative periprosthetic femur fracture is a known complication of total hip arthroplasty (THA) and a variety of cerclage systems are available to manage these fractures. The purpose of this study was to examine the in situ biomechanical response of cerclage systems for fixation of periprosthetic femur fractures that occur during cementless THA. We compared cobalt chrome (CoCr) cables, synthetic cables, monofilament wires and hose clamps under axial compressive and torsional loading. Metallic constructs with a positive locking system performed the best, supporting the highest loads with minimal implant subsidence (both axial and angular) after loading. Overall, the CoCr cable and hose clamp had the highest construct stiffness and least reduction in stiffness with increased loading. They were not demonstrably different from each other
Hemispherical and minimally invasive total hip reamers: a biomechanical analysis of use and design
Background: The purpose of this study was to determine the accuracy of used and new reamer systems for both hemispherical and minimally invasive (MIS) acetabular reamers.
Methods: New and used hemispherical and MIS acetabular reamers were tested on a computer numerical control machine to ream holes in special machinable wax blocks. Each reamer was tested 3 times in sizes 48 mm through 55 mm.
Results: The used reamers significantly underreamed by an average of 1.33 vs 0.28 mm compared to new reamers. Hemispherical reamers underreamed significantly more than MIS reamers, with a mean difference of 0.99 vs 0.63 mm, respectively. Used hemispherical reamers showed an average ream undersize of 1.61 vs 0.37 mm, compared to new hemispherical reamers. Used MIS reamers showed an average ream undersize of 1.06 vs 0.20 mm for the new MIS reamers.
Conclusions: For a manufacturer-specified reamer size, both hemispherical and MIS reamers underream. Newer reamers cut truer to expected values than used ones. MIS reamers performed more accurately than hemispherical reamers. Used acetabular reamer systems may negatively affect the sizing of prepared acetabular beds; therefore, awareness of this potential inaccuracy should be considered when performing total hip arthroplasty
Rivaroxaban Versus Enoxaparin for Venous Thromboembolism Prophylaxis after Hip and Knee Arthroplasty.
The oral Factor Xa inhibitor rivaroxaban (Xarelto) has been the pharmacologic agent used for venous thromboembolism (VTE) prophylaxis after primary hip and knee arthroplasty (THA/TKA) at our institution since February 2012. The purpose of our study was to compare rates of VTE and major bleeding between rivaroxaban and our previous protocol of enoxaparin after THA/TKA. A retrospective cohort study was performed including 2406 consecutive patients at our institution between 1/1/11 and 9/30/13. Patients who did not have unilateral primary THA/TKA or who received other anticoagulants were excluded. Of the 1762 patients included, 1113 patients (63.2%) received enoxaparin and 649 patients (36.8%) received rivaroxaban. This study found no demonstrable differences between these two anticoagulants in rates of VTE, infection, reoperation, transfusion, or major bleeding. Therapeutic, Retrospective comparative study, Level III
The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
Background: The purpose of this study was to investigate the stability of dual-taper modular implants following impaction forces delivered at varying locations as measured by the distraction forces required to disassemble the components.
Methods: Distraction of the head-neck and neck-stem (NS) tapers of dual-taper modular implants with 0°, 8°, and 15° neck angles were measured utilizing a custom-made distraction fixture attached to a servohydraulic materials test machine. Distraction was measured after hand pressing the components as well as following a simulated firm hammer blow impaction. Impacts to the 0°, 8°, 15° necks were directed axially in line with the neck, 10° anterior, and 10° proximal to the axis of the neck, respectively.
Results: Impaction increased the range of NS component distraction forces when compared to hand pressed components (1125-1743 N vs 248-302 N, respectively). Off-axis impacts resulted in significantly reduced mean (±95% confidence interval) distraction forces (8° neck, 1125 ± 117 N; 15° neck, 1212 ± 73 N), which were up to 35% lower than the mean distraction force for axial impacts to the 0° neck (1743 ± 138 N).
Conclusions: Direction of impaction influences stability of the modular interface. The greatest stability was achieved with impaction directed in line with the longitudinal axis of the taper junction. Off-axis impaction of the 8° and 15° neck led to significantly reduced stability at the NS. Improving stability of dual-taper modular hip prostheses with appropriately directed impaction may help to minimize micromotion, component settling, fretting corrosion, and subsequent failure
Topical vs Intravenous Tranexamic Acid in Primary Total Hip Arthroplasty: A Double-Blind, Randomized Controlled Trial.
BACKGROUND: Tranexamic acid (TXA) reduces perioperative blood loss in total hip arthroplasty (THA).
METHODS: In our randomized control trial, 139 patients were enrolled and received 2 g of either topical or intravenous (IV) TXA. Preoperative and postoperative protocols were standardized.
RESULTS: Calculated blood and Hgb loss were lower in the IV group (1195.0 ± 485.9 mL, 1442.7 ± 562.7 mL; P = .006), (160.3 [g] ± 63.8, 188.4 [g] ± 68.5; P = .014). There was a trend toward significance in transfusion reduction (11% [IV] vs 18% [topical]; P = .3). Both groups effectively reduced the transfusion rate. There was significant financial incentive for the use of TXA in THA with a savings of $314 per patient.
CONCLUSIONS: IV and topical TXA are effective tools to reduce blood loss and transfusion costs in THA, and we recommend the IV form for ease of use
Heterotopic Ossification Prophylaxis After Total Hip Arthroplasty: Randomized Trial of 400 vs 700 cGy.
BACKGROUND: Heterotopic ossification (HO) is a known complication following total hip arthroplasty. Radiation is an effective prophylaxis, but an optimal protocol has yet to be determined. We performed a randomized, double-blinded clinical trial in high-risk patients to determine the efficacy of 400 vs 700 cGy doses of radiation.
METHODS: One hundred forty-seven patients undergoing total hip arthroplasty and at high risk for HO at an urban medical center were randomized to receive either a single 400 or 700 cGy dose of radiation postoperatively. High risk was defined as a diagnosis of diffuse idiopathic skeletal hyperostosis, hypertrophic osteoarthritis, ankylosing spondylitis, or history of previous HO. Radiation was administered on the first or second postoperative day. A single blinded reviewer graded radiographs taken immediately postoperatively and at a minimum of 6 months postoperatively using the Brooker classification. Progression was defined as an increase in Brooker classification. Operative data including surgical approach, implant fixation, revision surgery, and postoperative range of motion data were also collected.
RESULTS: A significantly greater portion of patients who received the 400 cGy dose demonstrated progression of HO than patients who received the 700 cGy dose. There were no wound complications. No preoperative factors were associated with a higher rate of progression. Patients who progressed had less flexion on physical examination than patients who did not progress, but this was not clinically significant.
CONCLUSION: Seven hundred centigray was superior to 400 cGy in preventing HO formation following total hip arthroplasty in high-risk patients and may be the more effective treatment in this population. Further studies comparing 700 cGy to dosages between 400 and 700 cGy may help to clarify if a more optimal dose can be identified
Non-ischaemic cardiomyopathy associated with elevated serum cobalt and accelerated wear of a metal-on-metal hip resurfacing
A man in his late 30s developed non-ischaemic cardiomyopathy due to systemic cobalt toxicity associated with accelerated bearing surface wear from metal-on-metal hip resurfacing implanted in the previous 6 years. Following revision arthroplasty, the patient regained baseline cardiac function. Cobalt-induced cardiomyopathy is a grave condition that deserves early consideration due to potentially irreversible morbidity. We present this case to increase awareness, facilitate early detection and emphasise the need for research into the diagnosis and management of at-risk patients