19 research outputs found
Use of extended realities in cardiology
Recent miniaturization of electronic components and advances in image processing software have facilitated the entry of extended reality technology into clinical practice. In the last several years, the number of applications in cardiology has multiplied, with many promising to become standard of care. We review many of these applications in the areas of patient and physician education, cardiac rehabilitation, pre-procedural planning and intraprocedural use. The rapid integration of these approaches into the many facets of cardiology suggests that they will one day become an every-day part of physician practice
Can smartphone wireless ECGs be used to accurately assess ECG intervals in pediatrics? A comparison of mobile health monitoring to standard 12-lead ECG
BACKGROUND:Arrhythmias in children are often paroxysmal, complicating the ability to capture the abnormal rhythm on routine ECG during an outpatient visit. The Alivecor Kardia Mobile (KM) device is a wireless mobile health (mHealth) device that generates a single lead ECG tracing with a FDA-approved algorithm for detection of atrial fibrillation in adults. OBJECTIVE:The goal of this study is to assess the accuracy of interval measurements on KM tracings by directly comparing to standard 12-lead ECGs in pediatric patients. METHODS:This single center, prospective study enrolled pediatric outpatients, age 20ms with 4/9 (44%) having a conduction disorder and 2/9 (22%) having marked sinus arrhythmia. Bland-Altman method of agreement demonstrated strong agreement for QRSd and QTc. The AF algorithm reported 4/30 (13%) false positive "possible AF" diagnoses (rhythm over-read on KM demonstrated n = 3 marked sinus arrhythmia, n = 1 sinus rhythm with aberrated PACs) resulting in a specificity of 87%. CONCLUSION:The Alivecor Kardia device produces accurate single lead ECG tracings in both healthy children and children with cardiac disease or rhythm abnormalities across the pediatric spectrum. This mHealth application provides an accurate, non-invasive, real-time approach for ambulatory ECG monitoring in children and adolescents
Forceāsensing catheters during pediatric radiofrequency ablation: The FEDERATION Study
Background
Based on data from studies of atrial fibrillation ablations, optimal parameters for the TactiCath (TC; St. Jude Medical, Inc) forceāsensing ablation catheter are a contact force of 20Ā g and a forceātime integral of 400Ā gĀ·s for the creation of transmural lesions. We aimed to evaluate TC in pediatric and congenital heart disease patients undergoing ablation.
Methods and Results
Comprehensive chart and case reviews were performed from June 2015 to March 2016. Of the 102 patients undergoing electrophysiology study plus ablation, 58 (57%) underwent ablation initially with a forceāsensing catheter. Patients had an average age of 14 (2.4ā23) years and weight of 58 (18ā195) kg with 15 patients having abnormal cardiac anatomy. Electrophysiology diagnoses for the +
TC
group included 30 accessory pathwayāmediated tachycardia, 24 atrioventricular nodal reentrant tachycardia, and 7 other. Baseline generator settings included a power of 20Ā W, temperature of 40Ā°, and 6Ā cc/min flow during lesion creation with 11 patients (19%) having alterations to parameters. Seventeen patients (30%) converted to an alternate ablation source. A total of 516 lesions were performed using the
TC
with a median contact force of 6Ā g, forceātime integral of 149Ā gĀ·s, and lesion size index of 3.3. Medianāterm followāup demonstrated 5 (10%) recurrences with no acute or medianāterm complications.
Conclusions
TactiCath can be effectively employed in the treatment of pediatric patients with congenital heart disease with lower forces than previously described in the atrial fibrillation literature. Patients with atrioventricular nodal reentrant tachycardia or atrioventricular reciprocating tachycardia may not require transmural lesions and the
TC
may provide surrogate markers for success during slow pathway ablation.
</jats:sec
Percutaneous pulmonary valve implantation alters electrophysiologic substrate
BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is firstāline therapy for some congenital heart disease patients with right ventricular outflow tract dysfunction. The hemodynamics improvements after PPVI are well documented, but little is known about its effects on the electrophysiologic substrate. The objective of this study is to assess the shortā and mediumāterm electrophysiologic substrate changes and elucidate postprocedure arrhythmias. METHODS AND RESULTS: A retrospective chart review of patients undergoing PPVI from May 2010 to April 2015 was performed. AĀ total of 106 patients underwent PPVI; most commonly these patients had tetralogy of Fallot (n=59, 55%) and pulmonary insufficiency (n=60, 57%). The median followāup time was 28Ā months (7ā63Ā months). PreāPPVI, 25 patients (24%) had documented arrhythmias: nonsustained ventricular tachycardia (NSVT) (n=9, 8%), frequent premature ventricular contractions (PVCs) (n=6, 6%), and atrial fibrillation/flutter (AF/AFL) (n=10, 9%). PostāPPVI, arrhythmias resolved in 4 patients who had NSVT (44%) and 5 patients who had PVCs (83%). New arrhythmias were seen in 16 patients (15%): 7 NSVT, 8 PVCs, and 1 AF/AFL. There was resolution at mediumāterm followāup in 6 (86%) patients with newāonset NSVT and 7 (88%) patients with newāonset PVCs. There was no difference in QRS duration preāPPVI, postāPPVI, and at mediumāterm followāup (P=0.6). The median corrected QT lengthened immediately postāPPVI but shortened significantly at midterm followāup (P<0.01). CONCLUSIONS: PPVI reduced the prevalence of NSVT. The majority of postimplant arrhythmias resolve by 6Ā months of followāup
Implantable loop recorder monitoring for refining management of children with inherited arrhythmia syndromes
BACKGROUND: Implantable loop recorders (ILRs) are conventionally utilized to elucidate the mechanism of atypical syncope. The objective of this study was to assess the impact of these devices on management of pediatric patients with known or suspected inherited arrhythmia syndromes. METHODS AND RESULTS: A retrospective chart review was undertaken of all pediatric patients with known or suspected inherited arrhythmia syndromes in whom an ILR was implanted from 2008 to 2015. Captured data included categorization of diagnosis, treatment, transmitted tracings, and the impact of ILR tracings on management. Transmissions were categorized as symptomatic, autotriggered, or routine. Actionable transmissions were abnormal tracings that directly resulted in a change of medical or device therapy. A total of 20 patients met the stated inclusion criteria (long QT syndrome, n=8, catecholaminergic polymorphic ventricular tachycardia,n=9, Brugada syndrome, n=1, arrhythmogenic right ventricular cardiomyopathy, n=2), with 60% of patients being genotype positive. Primary indication for implantation of ILR included ongoing monitoring +/ā symptoms (n=15, 75%), suspicion of noncompliance (n=1, 5%), and liberalization of recommended activity restrictions (n=4, 25%). A total of 172 transmissions were received in patients with inherited arrhythmia syndromes, with 7% yielding actionable data. The majority (52%) of symptom events were documented in the long QT syndrome population, with only 1 tracing (5%) yielding actionable data. Automatic transmissions were mostly seen in the catecholaminergic polymorphic ventricular tachycardia cohort (81%), with 21% yielding actionable data. There was no actionable data in routine transmissions. CONCLUSIONS: ILRs in patients with suspected or confirmed inherited arrhythmia syndromes may be useful for guiding management. Findings escalated therapies in 30% of subjects. As importantly, in this highārisk population, the majority of symptom events represented normal or benign rhythms, reassuring patients and physicians that no further intervention was required
Implementation and early experience of a pediatric electrophysiology telehealth program
BACKGROUND: Telehealth (TH) visits have been growing with exponential increased utilization during the COVID-19 pandemic. The aim of this manuscript is to describe the implementation and early experience of a pediatric electrophysiology (EP) TH program implemented during the pandemic, assessing patient satisfaction, patient equity and inclusion (measured by geographical outreach), and sustainability.
METHODS: A retrospective chart review study was performed and data were collected from the medical record, including demographic, testing, and billing data from scheduled TH encounters between March and August 2020 of a single pediatric EP group in the Midwest. Patients were called to complete satisfaction surveys.
RESULTS: Patients with diverse pathologies were seen in TH, with supraventricular/atrial tachycardias (n = 41, 35%) and inherited arrhythmia syndromes (n = 23, 20%) being most common. The mean distance from clinic was 95 miles (range 2.8-320 miles), with 43% of patients living more than 100 miles away from clinic. A total of 172 tests were performed previsit (n = 102, 59%), during the visit (n = 17, 10%), or postvisit (n = 53, 31%), including 15 EP studies. Time-based Current Procedural Terminology codes were predominantly used for billing purposes (n = 92, 78%). There was generation of work relative value units (wRVU) for visits (220.5 wRVU) and testing (325.1 wRVU). Survey data demonstrated that 98% of patients were satisfied with their telehealth appointment and 99% had a clear understanding of their diagnosis.
CONCLUSION: Pediatric EP TH clinics can provide care for a geographically and pathologically heterogeneous group of patients who had positive attitudes toward TH. Our study shows significant downstream testing and subsequent wRVU generation, suggesting financial sustainability
Early preclinical experience of a mixed reality ultrasound system with active GUIDance for NEedle-based interventions: The GUIDE study
BACKGROUND: Use of ultrasound (US) to facilitate vascular access has increased compared to landmark-based procedures despite ergonomic challenges and need for extrapolation of 2-dimensional images to understand needle position. The MantUSā¢ system (Sentiar, Inc.,) uses a mixed reality (MxR) interface to display US images and integrate real-time needle tracking.
OBJECTIVE: The purpose of this prospective preclinical study was to evaluate the feasibility and usability of MantUS in a simulated environment.
METHODS: Participants were recruited from pediatric cardiology and critical care. Access was obtained in 2 vascular access training models: a femoral access model and a head and neck model for a total of 4 vascular access sites under 2 conditions-conventional US and MantUS. Participants were randomized for order of completion. Videos were obtained, and quality of access including time required, repositions, number of attempts, and angle of approach were quantified.
RESULTS: Use of MantUS resulted in an overall reduction in number of needle repositions (
CONCLUSION: Use of MantUS improved vascular access among all comers, including the quality of access. This improvement was even more notable in the vascular variant (RFV). MantUS readily benefited users by providing improved spatial understanding. Further development of MantUS will focus on improving user interface and experience, with larger clinical usage and in-human studies
Assessment of Apple Watch Series 6 pulse oximetry and electrocardiograms in a pediatric population
BACKGROUND: Recent technologic advances have resulted in increased development and utilization of direct-to-consumer cardiac wearable devices with various functionality. This study aimed to assess Apple Watch Series 6 (AW6) pulse oximetry and electrocardiography (ECG) in a cohort of pediatric patients.
METHODS: This single-center, prospective study enrolled pediatric patients ā„ 3kg and having an ECG and/or pulse oximetry (SpO2) as part of their planned evaluation. Exclusion criteria: 1) non-English speaking patients and 2) patients in state custody. Simultaneous tracings were obtained for SpO2 and ECG with concurrent standard pulse oximeter and 12-lead ECG. AW6 automated rhythm interpretations were compared to physician over-read and categorized as accurate, accurate with missed findings, inconclusive (automated interpretation: inconclusive ), or inaccurate.
RESULTS: A total of 84 patients were enrolled over a 5-week period. 68 patients (81%) were placed into the SpO2 and ECG arm, with 16 patients (19%) placed into the SpO2 only arm. Pulse oximetry data was successfully collected in 71/84 (85%) patients and ECG data in 61/68 (90%). ĪSpO2 between modalities was 2.0Ā±2.6% (r = 0.76). ĪRR was 43Ā±44msec (r = 0.96), ĪPR 19Ā±23msec (r = 0.79), ĪQRS 12Ā±13msec (r = 0.78), and ĪQT 20Ā±19msec (r = 0.9). The AW6 automated rhythm analysis yielded a 75% specificity and found: 1) 40/61 (65.6%) accurate , 2) 6/61 (9.8%) accurate with missed findings , 3) 14/61 (23%) inconclusive , and 4) 1/61 (1.6%) incorrect.
CONCLUSION: The AW6 can accurately measure oxygen saturation when compared to hospital pulse oximeters in pediatric patients and provide good quality single lead ECGs that allow for accurate measurement of RR, PR, QRS, and QT intervals with manual interpretation. The AW6-automated rhythm interpretation algorithm has limitations for smaller pediatric patients and patients with abnormal ECGs
IV sotalol use in pediatric and congenital heart patients: A multicenter registry study
Background There is limited information regarding the clinical use and effectiveness of IV sotalol in pediatric patients and patients with congenital heart disease, including those with severe myocardial dysfunction. A multicenter registry study was designed to evaluate the safety, efficacy, and dosing of IV sotalol. Methods and Results A total of 85 patients (age 1 day-36 years) received IV sotalol, of whom 45 (53%) had additional congenital cardiac diagnoses and 4 (5%) were greater than 18 years of age. In 79 patients (93%), IV sotalol was used to treat supraventricular tachycardia and 4 (5%) received it to treat ventricular arrhythmias. Severely decreased cardiac function by echocardiography was seen before IV sotalol in 7 (9%). The average dose was 1 mg/kg (range 0.5-1.8 mg/kg/dose) over a median of 60 minutes (range 30-300 minutes). Successful arrhythmia termination occurred in 31 patients (49%, 95% CI [37%-62%]) with improvement in rhythm control defined as rate reduction permitting overdrive pacing in an additional 18 patients (30%, 95% CI [19%-41%]). Eleven patients (16%) had significant QTc prolongation to \u3e465 milliseconds after the infusion, with 3 (4%) to \u3e500 milliseconds. There were 2 patients (2%) for whom the infusion was terminated early. Conclusions IV sotalol was safe and effective for termination or improvement of tachyarrhythmias in 79% of pediatric patients and patients with congenital heart disease, including those with severely depressed cardiac function. The most common dose, for both acute and maintenance dosing, was 1 mg/kg over ~60 minutes with rare serious complications