88 research outputs found

    Reference values for exhaled nitric oxide (reveno) study

    Get PDF
    BACKGROUND: Despite the widespread use of fractional exhaled nitric oxide (FE(NO)) as a biomarker of airways inflammation, there are no published papers describing normal FE(NO )values in a large group of healthy adults. OBJECTIVE: The aim of this study was to establish adult FE(NO )reference values according to the international guidelines. METHODS: FE(NO )was measured in 204 healthy, non-smoking adults with normal spirometry values using the on-line single-breath technique, and the results were analysed chemiluminescently. RESULTS: The main result of the study was the significant difference in FE(NO )values between men and women, thus indicating that gender-based reference FE(NO )values are necessary. The FE(NO )levels obtained at expiratory flows of 50 ml/s ranged from 2.6 to 28.8 ppb in men, and from 1.6 to 21.5 ppb in women. CONCLUSION: We propose reference FE(NO )values for healthy adult men and women that could be used for clinical and research purposes

    Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Get PDF
    BACKGROUND: Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). METHODS: A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). RESULTS: Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FE(NO )range of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. CONCLUSION: The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care

    IgE sensitisation in relation to flow-independent nitric oxide exchange parameters

    Get PDF
    BACKGROUND: A positive association between IgE sensitisation and exhaled NO levels has been found in several studies, but there are no reports on the compartment of the lung that is responsible for the increase in exhaled NO levels seen in IgE-sensitised subjects. METHODS: The present study comprised 288 adult subjects from the European Community Respiratory Health Survey II who were investigated in terms of lung function, IgE sensitisation (sum of specific IgE), smoking history and presence of rhinitis and asthma. Mean airway tissue concentration of NO (Caw(NO)), airway transfer factor for NO (Daw(NO)), mean alveolar concentration of NO (Calv(NO)) and fractional exhaled concentration of NO at a flow rate of 50 mL s(-1 )(FE(NO 0.05)) were determined using the extended NO analysis. RESULTS: IgE-sensitised subjects had higher levels (geometric mean) of FE(NO 0.05 )(24.9 vs. 17.3 ppb) (p < 0.001), Daw(NO )(10.5 vs. 8 mL s(-1)) (p = 0.02) and Caw(NO )(124 vs. 107 ppb) (p < 0.001) and positive correlations were found between the sum of specific IgE and FE(NO 0.05), Caw(NO )and Daw(NO )levels (p < 0.001 for all correlations). Sensitisation to cat allergen was the major determinant of exhaled NO when adjusting for type of sensitisation. Rhinitis and asthma were not associated with the increase in exhaled NO variables after adjusting for the degree of IgE sensitisation. CONCLUSION: The presence of IgE sensitisation and the degree of allergic sensitisation were related to the increase in airway NO transfer factor and the increase in NO concentration in the airway wall. Sensitisation to cat allergen was related to the highest increases in exhaled NO parameters. Our data suggest that exhaled NO is more a specific marker of allergic inflammation than a marker of asthma or rhinitis

    Tolerance and rebound with zafirlukast in patients with persistent asthma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The potential for tolerance to develop to zafirlukast, a cysteinyl leukotriene (CysLT) receptor antagonist (LRA) in persistent asthma, has not been specifically examined.</p> <p>Objective</p> <p>To look for any evidence of tolerance and potential for short-term clinical worsening on LRA withdrawal. Outcome measures included changes in; airway hyperresponsiveness to inhaled methacholine (PD<sub>20</sub>FEV<sub>1</sub>), daily symptoms and peak expiratory flows (PEF), sputum and blood cell profiles, sputum CysLT and prostaglandin (PG)E<sub>2 </sub>and exhaled nitric oxide (eNO) levels.</p> <p>Methods</p> <p>A double blind, placebo-controlled study of zafirlukast, 20 mg twice daily over 12 weeks in 21 asthmatics taking β<sub>2</sub>-agonists only (Group I), and 24 subjects treated with ICS (Group II).</p> <p>Results</p> <p>In Group I, zafirlukast significantly improved morning PEF and FEV<sub>1</sub>compared to placebo (p < 0.01), and reduced morning waking with asthma from baseline after two weeks (p < 0.05). Similarly in Group II, FEV<sub>1 </sub>improved compared to placebo (p < 0.05), and there were early within-treatment group improvements in morning PEF, β<sub>2</sub>-agonist use and asthma severity scores (p < 0.05). However, most improvements with zafirlukast in Group I and to a lesser extent in Group II deteriorated toward baseline values over 12 weeks. In both groups, one week following zafirlukast withdrawal there were significant deteriorations in morning and evening PEFs and FEV<sub>1 </sub>compared with placebo (p ≤ 0.05) and increased nocturnal awakenings in Group II (p < 0.05). There were no changes in PD<sub>20</sub>FEV<sub>1</sub>, sputum CysLT concentrations or exhaled nitric oxide (eNO) levels. However, blood neutrophils significantly increased in both groups following zafirlukast withdrawal compared to placebo (p = 0.007).</p> <p>Conclusion</p> <p>Tolerance appears to develop to zafirlukast and there is rebound clinical deterioration on drug withdrawal, accompanied by a blood neutrophilia.</p

    Clinical patterns in asthma based on proximal and distal airway nitric oxide categories

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The exhaled nitric oxide (eNO) signal is a marker of inflammation, and can be partitioned into proximal [J'aw<sub>NO </sub>(nl/s), maximum airway flux] and distal contributions [CA<sub>NO </sub>(ppb), distal airway/alveolar NO concentration]. We hypothesized that J'aw<sub>NO </sub>and CA<sub>NO </sub>are selectively elevated in asthmatics, permitting identification of four inflammatory categories with distinct clinical features.</p> <p>Methods</p> <p>In 200 consecutive children with asthma, and 21 non-asthmatic, non-atopic controls, we measured baseline spirometry, bronchodilator response, asthma control and morbidity, atopic status, use of inhaled corticosteroids, and eNO at multiple flows (50, 100, and 200 ml/s) in a cross-sectional study design. A trumpet-shaped axial diffusion model of NO exchange was used to characterize J'aw<sub>NO </sub>and CA<sub>NO</sub>.</p> <p>Results</p> <p>J'aw<sub>NO </sub>was not correlated with CA<sub>NO</sub>, and thus asthmatic subjects were grouped into four eNO categories based on upper limit thresholds of non-asthmatics for J'aw<sub>NO </sub>(≥ 1.5 nl/s) and CA<sub>NO </sub>(≥ 2.3 ppb): Type I (normal J'aw<sub>NO </sub>and CA<sub>NO</sub>), Type II (elevated J'aw<sub>NO </sub>and normal CA<sub>NO</sub>), Type III (elevated J'aw<sub>NO </sub>and CA<sub>NO</sub>) and Type IV (normal J'aw<sub>NO </sub>and elevated CA<sub>NO</sub>). The rate of inhaled corticosteroid use (lowest in Type III) and atopy (highest in Type II) varied significantly amongst the categories influencing J'aw<sub>NO</sub>, but was not related to CA<sub>NO</sub>, asthma control or morbidity. All categories demonstrated normal to near-normal baseline spirometry; however, only eNO categories with increased CA<sub>NO </sub>(III and IV) had significantly worse asthma control and morbidity when compared to categories I and II.</p> <p>Conclusions</p> <p>J'aw<sub>NO </sub>and CA<sub>NO </sub>reveal inflammatory categories in children with asthma that have distinct clinical features including sensitivity to inhaled corticosteroids and atopy. Only categories with increase CA<sub>NO </sub>were related to poor asthma control and morbidity independent of baseline spirometry, bronchodilator response, atopic status, or use of inhaled corticosteroids.</p

    Expiratory flow rate, breath hold and anatomic dead space influence electronic nose ability to detect lung cancer

    Get PDF
    BACKGROUND: Electronic noses are composites of nanosensor arrays. Numerous studies showed their potential to detect lung cancer from breath samples by analysing exhaled volatile compound pattern ("breathprint"). Expiratory flow rate, breath hold and inclusion of anatomic dead space may influence the exhaled levels of some volatile compounds; however it has not been fully addressed how these factors affect electronic nose data. Therefore, the aim of the study was to investigate these effects. METHODS: 37 healthy subjects (44 +/- 14 years) and 27 patients with lung cancer (60 +/- 10 years) participated in the study. After deep inhalation through a volatile organic compound filter, subjects exhaled at two different flow rates (50 ml/sec and 75 ml/sec) into Teflon-coated bags. The effect of breath hold was analysed after 10 seconds of deep inhalation. We also studied the effect of anatomic dead space by excluding this fraction and comparing alveolar air to mixed (alveolar + anatomic dead space) air samples. Exhaled air samples were processed with Cyranose 320 electronic nose. RESULTS: Expiratory flow rate, breath hold and the inclusion of anatomic dead space significantly altered "breathprints" in healthy individuals (p 0.05). These factors also influenced the discrimination ability of the electronic nose to detect lung cancer significantly. CONCLUSIONS: We have shown that expiratory flow, breath hold and dead space influence exhaled volatile compound pattern assessed with electronic nose. These findings suggest critical methodological recommendations to standardise sample collections for electronic nose measurements

    Mepolizumab for Treating Severe Eosinophilic Asthma: An Evidence Review Group Perspective of a NICE Single Technology Appraisal

    Get PDF
    As part of its single technology appraisal (STA) process, the National Institute for Health and Care Excellence (NICE) invited the company (GlaxoSmithKline) that manufactures mepolizumab (Nucala(®)) to submit evidence on the clinical and cost effectiveness of mepolizumab for the treatment of severe eosinophilic asthma. The School of Health and Related Research Technology Appraisal Group (ScHARR-TAG) at the University of Sheffield was commissioned to act as the independent evidence review group (ERG). The ERG produced a review of the evidence for the clinical and cost effectiveness of mepolizumab as add-on to standard of care (SoC) compared with SoC and omalizumab, based upon the company's submission to NICE. The clinical-effectiveness evidence in the company's submission was based predominantly on three randomised controlled trials (DREAM, MENSA and SIRIUS) comparing add-on mepolizumab with placebo plus SoC. The relevant population was defined in terms of degree of asthma severity (four or more exacerbations in the previous year and/or dependency on maintenance oral corticosteroids [mOCS]) and degree of eosinophilia (a blood eosinophil count of ≥ 300 cells/µl in the previous year) based on post hoc subgroup analyses of the pivotal trials. Other subpopulations were considered throughout the appraisal, defined by different eosinophil measurements, number of exacerbations and dependency (or lack thereof) on mOCS. Statistically significant reductions in clinically significant exacerbations were observed in patients receiving mepolizumab compared with SoC meta-analysed across MENSA and DREAM in the modified intention-to-treat (ITT) population (rate ratio [RR] 0.51; 95% confidence interval [CI] 0.42-0.62) as well as in the relevant population (RR 0.47; 95% CI 0.36-0.62). In terms of quality of life, differences on the St. George's Respiratory Questionnaire in MENSA for add-on subcutaneous mepolizumab 100 mg vs. placebo were 7 and 7.5 units in the modified ITT and relevant populations, respectively. A number of issues in the clinical evidence base warrant caution in its interpretation. The ERG noted that the definition of SoC used in the trials differed from that in clinical practice, where patients with severe uncontrolled asthma start treatment with a mOCS. The company's economic post-consultation analysis incorporating a confidential patient access scheme (PAS) estimated that the incremental cost-effectiveness ratio (ICER) for add-on mepolizumab compared with SoC was £27,418 per quality-adjusted life-year (QALY) gained in the relevant population if patients stopped mepolizumab after 1 year unless (1) the number of exacerbations decreased at least 50% or (2) a reduction in corticosteroids dose was achieved whilst maintaining asthma control. The ERG applied an age adjustment to all utilities and corrected the post-continuation assessment utilities, which resulted in an ICER for add-on mepolizumab compared with SoC of £29,163 per QALY gained. The ERG noted that this ICER was not robust for patients who continued treatment due to a corticosteroid dose reduction where exacerbations had decreased by less than 50%, because corticosteroid dose reduction was not allowed in the main trial in which the evidence was gathered (MENSA). The NICE appraisal committee (AC) concluded that add-on mepolizumab could be recommended as an option for treating severe refractory eosinophilic asthma in adults for the relevant population when the stopping rule suggested by the company was applied. The AC also concluded that the comparison between mepolizumab and omalizumab was not clinically relevant or methodologically robust

    The Urban Environment and Childhood Asthma (URECA) birth cohort study: design, methods, and study population

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The incidence and morbidity of wheezing illnesses and childhood asthma is especially high in poor urban areas. This paper describes the study design, methods, and population of the Urban Environment and Childhood Asthma (URECA) study, which was established to investigate the immunologic causes of asthma among inner-city children.</p> <p>Methods and Results</p> <p>URECA is an observational prospective study that enrolled pregnant women in central urban areas of Baltimore, Boston, New York City, and St. Louis and is following their offspring from birth through age 7 years. The birth cohort consists of 560 inner-city children who have at least one parent with an allergic disease or asthma, and all families live in areas in which at least 20% of the population has incomes below the poverty line. In addition, 49 inner-city children with no parental history of allergies or asthma were enrolled. The primary hypothesis is that specific urban exposures in early life promote a unique pattern of immune development (impaired antiviral and increased Th2 responses) that increases the risk of recurrent wheezing and allergic sensitization in early childhood, and of asthma by age 7 years. To track immune development, cytokine responses of blood mononuclear cells stimulated <it>ex vivo </it>are measured at birth and then annually. Environmental assessments include allergen and endotoxin levels in house dust, pre- and postnatal maternal stress, and indoor air nicotine and nitrogen dioxide. Nasal mucous samples are collected from the children during respiratory illnesses and analyzed for respiratory viruses. The complex interactions between environmental exposures and immune development will be assessed with respect to recurrent wheeze at age 3 years and asthma at age 7 years.</p> <p>Conclusion</p> <p>The overall goal of the URECA study is to develop a better understanding of how specific urban exposures affect immune development to promote wheezing illnesses and asthma.</p

    Residential Proximity to a Major Roadway Is Associated with Features of Asthma Control in Children

    Get PDF
    BACKGROUND: While several studies suggest that traffic-related air pollutants are detrimental for respiratory health, few studies have examined relationships between residential proximity to a major roadway and asthma control in children. Furthermore, a major limitation of existing research is reliance on self-reported outcomes. We therefore determined the spatial relationship between the distance from a major roadway and clinical, physiologic and inflammatory features of asthma in a highly characterized sample of asthmatic children 6-17 years of age across a wide range of severities. We hypothesized that a closer residential proximity to a major roadway would be associated with increased respiratory symptoms, altered pulmonary function and a greater magnitude of airway and systemic inflammation. METHODOLOGY/PRINCIPAL FINDINGS: 224 children 6-17 years with confirmed asthma completed questionnaires and underwent spirometry, plethysmography, exhaled nitric oxide determination, exhaled breath condensate collection and venipuncture. Residential distance from a major roadway was determined by mapping the geographic coordinates of the residential address in Geographic Information System software. The distance between the home address and the nearest major roadway was calculated according to the shortest distance between the two points (i.e., "as the crow flies"). Asthmatic children living in closer proximity to a major roadway had an increased frequency of wheezing associated with increased medication requirements and more hospitalizations even after controlling for potential confounders. These children also had increased airway resistance, increased airway inflammation reflected by a lower breath condensate pH, and higher plasma EGF concentrations. CONCLUSIONS/SIGNIFICANCE: These findings suggest that closer residential proximity to a major roadway is associated with poorer asthma control in school-age children. Assessment of residential proximity to major roadways may be useful in the clinical evaluation of asthma in children
    • …
    corecore