99 research outputs found

    Ascending Aneurysms in Bicuspid Aortic Valve

    Get PDF

    Atrial natiuretic peptide release at rest and with exercise after cardiac transplantation with bicaval anastomoses

    Get PDF
    AbstractBicaval anastomoses in orthotopic cardiac transplantation offer the advantage of preserving the right atrial geometry. To elucidate the impact of this anastomotic technique on atrial natriuretic peptide plasma levels at rest and with exercise, nine patients were submitted to a symptom-limited supine exercise test. Atrial natriuretic peptide plasma levels in samples obtained from the right atrium were elevated at rest (274.4 ± 60.4 pg/ml), at peak exercise (438.1 ± 71.7 pg/ml), and thereafter (328.1 ± 71.2 pg/ml) with respect to normal reference values of 21 ± 1 pg/ml at rest and 92 ± 14 at peak exercise. Renin, angiotensin, and aldosterone plasma levels were almost normal and did not indicate any pathologic processes in volume homeoostasis. Right-sided hemodynamic parameters were not correlated with atrial natriuretic peptide secretion. An adverse relationship between cold ischemic time of the donor organ and atrial natriuretic peptide release was found ( r = 0.88, p < 0.0008), indicating that endocrine cardiocytes are sensitive to prolonged ischemia. Atrial natriuretic peptide release may thus be independent of the surgical approach, and other unique characteristics of the transplanted heart, such as denervation, are more likely to be responsible for elevated atrial natriuretic peptide plasma concentrations after orthotopic heart transplantation. (J THORAC CARDIOVASC SURG 1995;110:1600-5

    Fourteen years' experience with 501 subcoronary Ross procedures: Surgical details and results

    Get PDF
    ObjectiveDuring the past decade the Ross procedure using the full root has become the predominant surgical technique. However, progressive autograft dilatation and eventual failure remain a concern. Here we report on the surgical techniques and results of the subcoronary technique over a 14-year period.MethodsA total of 501 patients (mean age, 44.9 ± 12.9 years; 117 female; 384 male) were operated on from June 1994 to December 2007. The follow-up database, with a completeness of 98.2%, was closed on December 2008, comprising of 2931 patient-years with a mean follow-up of 5.9 ± 3.6 years (range, 0.1–14.1 years).ResultsSurgical details are presented. Early and late mortality were 0.4% (n = 2) and 4% (n = 20), respectively, valve-related mortality was 1.2% (n = 6), whereas the overall survival did not differ from that of the normal population. Neurologic events occurred in 22 patients, major bleeding in 9, autograft endocarditis in 8, and homograft endocarditis in 10. Freedom from autograft and homograft reoperation was 91.9% at 10 years. For the majority of patients, hemodynamics was excellent and no root dilatation was observed.ConclusionsMidterm results after the original subcoronary Ross procedure are excellent, including normal survival and low risk of valve-related morbidity. Longer-term results are necessary for continuous judgment of the subcoronary technique

    Pathway Analysis of Differentially Expressed Genes in Patients with Acute Aortic Dissection

    Get PDF
    Background: Acute aortic dissection (AAD) is a life-threatening condition with high mortality and a relatively unclarified pathophysiological mechanism. Although differentially expressed genes in AAD have been recognized, interactions between these genes remain poorly defined. This study was conducted to gain a better understanding of the molecular mechanisms underlying AAD and to support the future development of a clinical test for monitoring patients at high risk. Materials and Methods: Aortic tissue was collected from 19 patients with AAD (mean age 61.7 ± 13.1 years), and from eight other patients (mean age 32.9 ± 12.2 years) who carried the mutated gene for Marfan syndrome (MS). Six patients (mean age 56.7 ± 12.3 years) served as the control group. The PIQOR TM Immunology microarray with 1076 probes in quadruplicates was utilized; the differentially expressed genes were analysed in a MedScan search using PathwayAssist software. Quantitative reverse transcription-polymerase chain reaction (qRT-PCR) and protein analysis were performed. Results: Interactions of MS fibrillin-1 (FBN1) in the MedScan pathway analysis showed four genes, fi bulin-1 (FBLN1), fi bulin-2 (FBLN2), decorin (DCN) and microfi brillar associated protein 5 (MFAP5), which were differentially expressed in all tissue from AAD. The validation of these genes by qRT-PCR revealed a minimum of three-fold downregulation of FBLN1 (0.5 ± 0.4 vs. 6.1 ± 2.3 fold, p = 0.003) and of DCN (2.5 ± 1.0 vs. 8.5 ± 4.7 fold, p = 0.04) in AAD compared to MS and control samples. Conclusions: Downregulation of fibrillin-1 (FBN1) may weaken extracellular components in the aorta and/or interfer with the transmission of cellular signals and eventually cause AAD. Additional research on these four identified genes can be a starting point to develop a diagnostic tool

    Elevation of Matrix Metalloproteinases in Different Areas of Ascending Aortic Aneurysms in Patients with Bicuspid and Tricuspid Aortic Valves

    Get PDF
    Our aim is to investigate the elevation of matrix proteins in tissues obtained from distal, above the sinotubular junction (proximal), concave, and convex sites of aneurysms in the ascending aorta using a simultaneous multiplex protein detection system. Tissues were collected from 41 patients with ascending aortic aneurysms. A total of 31 patients had a bicuspid aortic valve (BAV), whereas 10 had a tricuspid aortic valve (TAV). Concave and convex aortic site samples were collected from all patients, whereas proximal and distal convexity samples were obtained from 19 patients with BAV and 7 patients with TAV. Simultaneous detection of matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) was performed at each of the four aortic sites. MMP-2 levels were higher in the concave aortic sites than in the convex aortic sites. In contrast, MMP-8 levels were higher in the convex sites than in the concave sites, as were MMP-9 levels. In both BAV and TAV patients, TIMP-3 levels were higher in the concave sites than in the convex sites. However, TIMP-2 and TIMP-4 levels were significantly elevated in the sinotubular proximal aorta of BAV patients. Simultaneous detection of MMPs and TIMPs revealed different levels at different aortic sites in the same patient
    corecore