19 research outputs found

    A proteomic approach to investigating gene cluster expression and secondary metabolite functionality in Aspergillus fumigatus.

    Get PDF
    A combined proteomics and metabolomics approach was utilised to advance the identification and characterisation of secondary metabolites in Aspergillus fumigatus. Here, implementation of a shotgun proteomic strategy led to the identification of non-redundant mycelial proteins (n = 414) from A. fumigatus including proteins typically under-represented in 2-D proteome maps: proteins with multiple transmembrane regions, hydrophobic proteins and proteins with extremes of molecular mass and pI. Indirect identification of secondary metabolite cluster expression was also achieved, with proteins (n = 18) from LaeA-regulated clusters detected, including GliT encoded within the gliotoxin biosynthetic cluster. Biochemical analysis then revealed that gliotoxin significantly attenuates H2O2-induced oxidative stress in A. fumigatus (p>0.0001), confirming observations from proteomics data. A complementary 2-D/LC-MS/MS approach further elucidated significantly increased abundance (p<0.05) of proliferating cell nuclear antigen (PCNA), NADH-quinone oxidoreductase and the gliotoxin oxidoreductase GliT, along with significantly attenuated abundance (p<0.05) of a heat shock protein, an oxidative stress protein and an autolysis-associated chitinase, when gliotoxin and H2O2 were present, compared to H2O2 alone. Moreover, gliotoxin exposure significantly reduced the abundance of selected proteins (p<0.05) involved in de novo purine biosynthesis. Significantly elevated abundance (p<0.05) of a key enzyme, xanthine-guanine phosphoribosyl transferase Xpt1, utilised in purine salvage, was observed in the presence of H2O2 and gliotoxin. This work provides new insights into the A. fumigatus proteome and experimental strategies, plus mechanistic data pertaining to gliotoxin functionality in the organism

    The response of a tensioned roof to the action of an acoustic wave

    No full text
    Hala Główna „Spodek” w Katowicach jest jedną z największych hal widowiskowo-sportowych w Polsce. Budowa prowadzona była w latach 60. ubiegłego wieku, a rozpoczęcie użytkowania miało miejsce w 1971 roku. W 2011 roku został przeprowadzony remont, w ramach którego wymieniono elewację z płyt azbestowo-cementowych oraz dokonano modernizacji nagłośnienia hali. Wprowadzenie nowych urządzeń emitujących dźwięk, szczególnie o niskiej częstotliwości, stwarzało ryzyko, że odpowiedź konstrukcji przekrycia dachowego może objawiać się istotnymi wartościami przemieszczeń. Zaplanowano zatem badania, w ramach których prowadzono pomiary parametrów fizycznych związanych z pracą konstrukcji w warunkach oddziaływania fali akustycznej.The Spodek building in Katowice is one of the largest indoor sports and entertainment venues in Poland. It was built in the 1960s, and opened in 1971. In 2011 a repair programme was carried out, including the replacement of the elevation made of asbestos-cement panels, and modernization of the venue’s amplification systems. The introduction of new sound-emitting devices, particularly those of low frequency, created a risk that the response of the roof structure might be manifested in significant values of displacement. It was therefore planned to carry out tests in which measurements would be made of physical parameters relating to the behaviour of the structure under the action of an acoustic wave

    Application of optical fibers in engineering measurements on the example of selected laboratory tests

    No full text
    W artykule opisano wybrane przykłady badań laboratoryjnych, których celem było zweryfikowanie przydatności światłowodowej techniki pomiarowej do praktycznych zastosowań inżynierskich. Światłowody, ze względu na wiele zalet, mają szansę stać się przełomem w dziedzinie inżynierii lądowej zwanej monitorowaniem konstrukcji (ang. structural health monitoring). Do rozwiązania pozostaje jednak wiele problemów technicznych, związanych między innymi ze sposobem montażu i zabezpieczenia delikatnych włókien światłowodowych przed uszkodzeniami mechanicznymi. Opracowanie rozwiązań umożliwiających pozyskiwanie wiarygodnej i kompleksowej wiedzy na temat pracy obiektu budowlanego ma w ogólności prowadzić do poprawy jego bezpieczeństwa przy jednoczesnym minimalizowaniu nakładów finansowych.The article describes some examples of laboratory tests, which aim was to verify the usefulness of fiber optic measurement technology for practical engineering applications. Optical fibers, due to the many advantages, have a chance to become a crucial solution in the field of civil engineering called structural health monitoring. However, there are many problems to solve related to, inter alia, the way of mounting and protection of weak fibers from mechanical damage. Preparing solutions for obtaining reliable and comprehensive knowledge about structure operation should generally lead to improved safety, while minimizing financial outlay

    Pomiary dynamiczne - czy to się opłaca?

    No full text
    Instalacja systemów monitorowania dynamicznego w czasie budowy generującej drgania wiąże się z wieloma praktycznymi korzyściami, ale także z koniecznością poniesienia pewnych nakładów. Z pewnością koszty związane z wystąpieniem awarii istniejących obiektów będą zawsze większe od kosztów samego systemu, którego zadaniem jest wczesne ostrzeganie o zagrożeniach. Jednak w celu podejmowania optymalnych decyzji inwestycyjnych, konieczne jest uwzględnienie teorii prawdopodobieństwa i niezawodności konstrukcji.Installation of dynamic structural health monitoring systems during construction generating vibrations is associated with many practical benefits but also with the necessity of some expenses. Certainly, the costs associated with the failures of existing facilities will always be higher than the costs of the system itself, which task is to provide early warning of hazards. However, in order to make optimal investment decisions, it is necessary to consider the theory of probability and structural reliability

    A structural health monitoring system for a cylindrical coal tank

    No full text
    Referat opisuje zastosowanie systemu monitorowania konstrukcji (SHM) do oceny stanu wytężenia zbiornika na węgiel znajdującego się w niskim stanie technicznym. Podano sposób prowadzenia monitoringu, typ czujników oraz opisano podstawowe wyniki. Zastosowanie współczesnego narzędzia wspomagającego diagnozę konstrukcji umożliwiło wydłużenie okresu użytkowania zbiornika o kilka lat.This paper describes the use of a structural health monitoring (SHM) system to evaluate stress in a coal tank being in poor technical condition. The method of monitoring and the type of sensors are presented, and basic results are described. The use of a modern tool assisting structural diagnosis has made it possible to extend the lifetime of the tank by several years

    Structural health monitoring systems for prestressed structures

    No full text
    Technologię sprężania wykorzystuje się przede wszystkim w elementach o dużych rozpiętościach, przenoszących znaczne obciążenia, których konsekwencje zniszczenia byłyby bardzo duże. Dlatego istotne jest, aby proces projektowania, wznoszenia oraz późniejszej eksploatacji takich obiektów był odpowiednio kontrolowany.Prestressing technology is primarily used for a large-span elements, carrying heavy loads, which failure consequences would be very substantial. Thus, it is essential to control adequately the process of designing, erecting and further operating of such kind of objects. Computational procedures, presented in the standards, allow for the safe design, but do not provide the full knowledge about structure’s work in its real conditions of use. This knowledge could be acquired by interpreting the results of measurements made by structural health monitoring systems. This article presents an overview of the most important ways to monitor the work of prestressed elements based on selected systems implemented in different types of objects in Poland

    Wykorzystanie drgań samowzbudnych do dynamicznych pomiarów odkształceń realizowanych za pomocą tensometrów z drgającą struną

    No full text
    This study examines a set of vibrating wire extensometers in which a van der Pol generator has been used to maintain the natural vibrations of the wire. Excited in this way, self-exited vibrations allow for uninterrupted strain measurements over time, including fast-changing strains as well as chaotic nature strains. For the two typical vibrating wire gauges used in the industry, the impact of the wire extension speed on its metrological characteristics and applicability has been analyzed.W pracy poddano analizie układ ekstensometru strunowego, w którym w celu utrzymania niegasnących drgań własnych struny zastosowano generator van der Pola. Wzbudzone w ten sposób drgania samowzbudne pozwalają na nieprzerwany w czasie pomiar odkształceń, w tym również odkształceń szybkozmiennych i o charakterze chaotycznym. Dla dwóch typowych czujników strunowych stosowanych w przemyśle przeanalizowano wpływ szybkości rozciągania struny na jej właściwości metrologiczne i możliwości zastosowania

    Experiences from making use of structural health monitoring of a rail bridge structure impacted by mining deformations

    No full text
    W wyniku prowadzonej eksploatacji górniczej dochodzi do deformacji powierzchni terenu. W przypadku obiektów liniowych, takich jak obiekty mostowe, ważne jest wzajemne położenie względem siebie poszczególnych elementów mostu: przęseł, filarów, podpór. Na przemieszczanie się tych elementów ma wpływ zarówno charakter górniczych deformacji terenu, jak i układ ułożyskowania. Wrażliwa na deformacje terenu konstrukcja mostu wymaga stałej kontroli jego geometrii. Zastosowanie automatycznego systemu monitorowania pozwala na zwiększenie jakości i dokładności informacji o zmianach zachodzących w obiekcie przy jednoczesnym obniżeniu nakładu pracy na pozyskiwanie danych i ich analizę, co przekłada się w istotny sposób na wzrost bezpieczeństwa analizowanej konstrukcji. W artykule opisano doświadczenia z użytkowania systemu monitorowania konstrukcji mostu kolejowego poddanego oddziaływaniu eksploatacji górniczej. Dokonano analizy potrzeb związanych z ciągłą kontrolą stanu technicznego, podano zasady budowy systemu oraz przedstawiono pierwsze wyniki pracy automatycznego systemu monitorowania zainstalowanego na obiekcie.Mining area deformations occur as a result of mining exploitation. In the case of linear objects such as bridge objects, it is important to mutual putting towards the elements of a bridge such as: spans, pillars, supports. The displacements of these elements depend on the nature of mining deformation and also on the system of bearings. Bridge structure susceptible to area deformation requires constant monitoring of its geometry. The use of automatic SHM system allows to increase the quality and accuracy of information relating to the changes occurring within the structure, while reducing the amount of work for data acquisition and analysis, resulting in a significant increase of the structure safety. This paper presents the experiences from making use of the monitoring system for structures of a railway bridge subjected to the influence of mining exploitation. The paper also presents an analysis of requirements for the continuous control of the structural health of a bridge structure, the rules of building of the automatic SHM and the first results of the automatic SHM system installed on the structure

    Odkształcenia mostu z kompozytów FRP w świetle różnych metod pomiarowych

    No full text
    Konstrukcje mostowe zbudowane z kompozytów FRP charakteryzują się bardzo małym ciężarem zapewniającym łatwy transport i szybki montaż, możliwościami prefabrykacji całych przęseł, bardzo dużą wytrzymałością, doskonałą trwałością, odpowiednią sztywnością i dobrymi parametrami dynamicznymi. W referacie przedstawiono wyniki pomiarów odkształceń belkowego przęsła mostu typu all-composite. Pomiary odkształceń pod obciążeniem statycznym wykonano trzema różnymi metodami: metodą konwencjonalnej tensometrii elektrooporowej oraz za pomocą technologii strunowej i za pomocą rozłożonych czujników światłowodowe DFOS (ang. distributed fibre optic sensors). Przeprowadzone badania wykazały bardzo dużą zgodność odkształceń pomierzonych tymi metodami. Porównanie trzech technologii pomiarowych pozwoliło także na wybór technologii najbardziej odpowiedniej dla mostów kompozytowych.The all-composite bridges in which both the girder and deck slab are fully made of FRP composite, are characterized by: a very low weight, prefabrication even entire spans, very high strength, excellent durability, appropriate stiffness, and proper dynamic behavior of the bridge. The mail results of strain measurement in the all-composite bridge span under static load test have been presented. Three different measurement methods have been applied: vibrating strain gauge, distributed fibre optic sensors (DFOS) and strain gauge transducer. The proof load tests have revealed the good agreement and consistency between these results. The comparison made on the basis of measurements has allowed to choose the most appropriate method to be used in the further monitoring system of the bridge

    Strains of all-FRP composite bridge measured by the different methods

    No full text
    Konstrukcje mostowe zbudowane z kompozytów FRP charakteryzują się bardzo małym ciężarem zapewniającym łatwy transport i szybki montaż, możliwościami prefabrykacji całych przęseł, bardzo dużą wytrzymałością, doskonałą trwałością, odpowiednią sztywnością i dobrymi parametrami dynamicznymi. W referacie przedstawiono wyniki pomiarów odkształceń belkowego przęsła mostu typu all-composite. Pomiary odkształceń pod obciążeniem statycznym wykonano trzema różnymi metodami: metodą konwencjonalnej tensometrii elektrooporowej oraz za pomocą technologii strunowej i za pomocą rozłożonych czujników światłowodowe DFOS (ang. distributed fibre optic sensors). Przeprowadzone badania wykazały bardzo dużą zgodność odkształceń pomierzonych tymi metodami. Porównanie trzech technologii pomiarowych pozwoliło także na wybór technologii najbardziej odpowiedniej dla mostów kompozytowych.The all-composite bridges in which both the girder and deck slab are fully made of FRP composite, are characterized by: a very low weight, prefabrication even entire spans, very high strength, excellent durability, appropriate stiffness, and proper dynamic behavior of the bridge. The mail results of strain measurement in the all-composite bridge span under static load test have been presented. Three different measurement methods have been applied: vibrating strain gauge, distributed fibre optic sensors (DFOS) and strain gauge transducer. The proof load tests have revealed the good agreement and consistency between these results. The comparison made on the basis of measurements has allowed to choose the most appropriate method to be used in the further monitoring system of the bridge
    corecore