21 research outputs found

    Single Balloon Enteroscopy-Assisted ERCP Using Rendezvous Technique for Sharp Angulation of Roux-en-Y Limb in a Patient with Bile Duct Stones

    Get PDF
    The acute angulation of Roux-en-Y (R-Y) limb precludes endoscopic access for endoscopic retrograde cholangiopancreatography (ERCP) even using a balloon enteroscopy. Here, we describe a case of successful single balloon enteroscopy (SBE)-assisted ERCP using a rendezvous technique in a patient with sharply angulated R-Y limb in a 79-year-old woman who had bile duct stones. Method. At first, a guidewire was passed antegradely through the major papilla after the needle puncture using percutaneous transhepatic biliary drainage technique. A hydrophilic guidewire with an ERCP catheter was antegradely advanced beyond the Roux limb. After a guidewire was firmly grasped by a snare forceps, it was pulled out of the body, resulting that the enteroscope could advance to the papilla. After papillary dilation, complete removal of bile duct stones was achieved without any procedure-related complication. In conclusion, although further study is needed, SBE-assisted ERCP using a rendezvous technique may have a potential for selected patients

    Transpapillary incision of refractory circumscript pancreatic duct stricture using wire-guided snare forceps

    No full text
    Endoscopic therapy of pancreatic duct (PD) strictures using balloon dilation and pancreatic duct stent (PS) placement has been reported to improve the severity of abdominal pain in selected patients with chronic pancreatitis (CP). However, some strictures are refractory and require frequent PS exchange to control symptoms. We describe two cases of successful endoscopic PD incision for difficult PD stricture using a wire-guided snare. The snare is partially opened within the strictured pancreatic duct while applying current, thus incising the duct. Although both cases were successful without complications we do not advocate that this method be used routinely because of the potential for severe complications, e.g. bleeding, ductal perforation or pancreatic parenchymal damage. In order to prevent these complications, we developed a wire-guided technique under fluoroscopic control. We think this procedure may be useful in patients with short, straight PD strictures. Although further study is required, this approach may have potential for selected patients with refractory PD strictures due to CP

    Transnasal endoscopic biliary drainage as a rescue management for the treatment of acute cholangitis

    No full text
    Endoscopic biliary drainage has been established to provide effective treatment for acute obstructive jaundice and cholangitis. A recently developed ultrathin transnasal videoendoscope (TNE) is minimally invasive even for critically ill patients and can be performed without conscious sedation. Transnasal endoscopic biliary drainage (TNE-BD) is performed using a front-viewing TNE with approximately 5 mm outer diameter and 2 mm working channel diameter. Finally, 5F naso-biliary tube or plastic stent are placed. Technical success rates are approximately 100% and 70% for post-endoscopic sphincterotomy or placement of self-expandable metallic stent, and intact papilla, respectively. There are no serious complications. In conclusion, although further cases should be accumulated, TNE-BD and in particular, one-step naso-biliary drainage using TNE may be a useful and novel technique for the treatment of acute cholangitis

    Endoscopic ultrasound-guided choledochoduodenostomy in patients with failed endoscopic retrograde cholangiopancreatography

    No full text
    Endoscopic ultrasonography (EUS)-guided biliary drainage was performed for treatment of patients who have obstructive jaundice in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). In the present study, we introduced the feasibility and outcome of EUS-guided choledochoduodenostomy in four patients who failed in ERCP. We performed the procedure in 2 papilla of Vater, including one resectable case, and 2 cases of cancer of the head of pancreas. Using a curved linear array echoendoscope, a 19 G needle or a needle knife was punctured transduodenally into the bile duct under EUS visualization. Using a biliary catheter for dilation, or papillary balloon dilator, a 7-Fr plastic stent was inserted through the choledochoduodenostomy site into the extrahepatic bile duct. In 3 (75%) of 4 cases, an indwelling plastic stent was placed, and in one case in which the stent could not be advanced into the bile duct, a naso-biliary drainage tube was placed instead. In all cases, the obstructive jaundice rapidly improved after the procedure. Focal peritonitis and bleeding not requiring blood transfusion was seen in one case. In this case, pancreatoduodenectomy was performed and the surgical findings revealed severe adhesion around the choledochoduodenostomy site. Although further studies and development of devices are mandatory, EUS-guided choledochoduodenostomy appears to be an effective alternative to ERCP in selected cases

    Endoscopic removal and trimming of distal self-expandable metallic biliary stents

    No full text
    AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS)
    corecore