7 research outputs found

    EN-BIRTH Data Collector Training - Supporting Annexes

    Get PDF
    The EN-BIRTH study aims to validate selected newborn and maternal indicators for routine facility-based tracking of coverage and quality of care for use at district, national and global levels. The item contains consent forms and participant information, in addition to standard operating procedures (SOP) for adverse clinical events, and managing distress in interviews. The full complement of annex files used during the training can be requested via this site if required

    EN-BIRTH Data Collection Tools

    Get PDF
    The EN-BIRTH study aims to validate selected newborn and maternal indicators for routine facility-based tracking of coverage and quality of care for use at district, national and global levels. The item contains the following data collection tools: Register data extraction, Observation checklist (labour and delivery ward), Observation checklist (kangaroo mother care), Patient record verification tools for antenatal corticosteroid administration, Patient record verification tools for antibiotic administration, and the Maternal recall survey

    EN-BIRTH Data Collector Training – Training Module material

    Get PDF
    The EN-BIRTH study aims to validate selected newborn and maternal indicators for routine facility-based tracking of coverage and quality of care for use at district, national and global levels. The item contains PowerPoint slides used for the nine modules of the Data Collector's Training Programme delivered during May and June 2017. Module 1 (introduction) provides an overview of the training syllabus; Module 2 (Registration) helps tracking officers to understand their roles and responsibilities in the project and how to best execute them; Module 3 (Observation: Labour & Delivery) is intended to help Labour & Delivery observers to conduct themselves, and their work, in accordance with project guidelines and training handbook; Module 4 (Observation: Resuscitation - Nepal) covers the function of CCTV cameras and the value of collecting extra observation data from filmed clinical events; Module 5 (Observation: KMC) outlines expectations and practices to be applied by KMC (kangaroo mother care) observers; Module 6 (Data Extraction & Verification) outlines how data collectors should extract and verify register data and record information in the app extraction form in the L&D ward and KMC ward; Module 7 (Maternal Pre-discharge Recall Survey) outlines how to conduct high-quality interviews and administer the maternal pre-discharge recall survey; Module 8 (Supervision) equips supervisors with the skills to be good team managers, ensure team effectiveness and happiness, respond to incidents in the health facility, and monitor data quality; and finally Module 9 (Training Summary) provides a recap of key information taught over the week

    The Association of Women's Empowerment with Stillbirths in Nepal

    No full text
    INTRODUCTION: Globally, 2.6 million stillbirths occur each year. Empowering women can improve their overall reproductive health and help reduce stillbirths. Women empowerment has been defined as women's ability to make choices in economic decision-making, household and health care decision-making. In this paper, we aimed to evaluate if women's empowerment is associated with stillbirths. METHODS: Data from 2016 Nepal Demographic Health Surveys (NDHS) were analysed to evaluate the association between women's empowerment and stillbirths. Equiplots were generated to assess the distribution of stillbirths by wealth quintile, place of residence and level of maternal education using data from NHDS 1996, 2001, 2006, 2011 and 2016 data. For the association of women empowerment factors and stillbirths, univariate and multivariate analyses were conducted. RESULTS: A total of 88 stillbirths were reported during the survey. Univariate analysis showed age of mother, education of mother, age of husband, wealth index, head of household, decision on healthcare and decision on household purchases had significant association with stillbirths (p < 0.05). In multivariate analysis, only maternal age 35 years and above was significant (aOR 2.42; 1.22-4.80). Education of mother (aOR 1.48; 0.94-2.33), age of husband (aOR 1.54; 0.86-2.76), household head (aOR 1.51; 0.88-2.59), poor wealth index (aOR 1.62; 0.98-2.68), middle wealth index (aOR 1.37; 0.76-2.47), decision making for healthcare (aOR 1.36; 0.84-2.21) and household purchases (aOR 1.01; 0.61-1.66) had no any significant association with stillbirths. CONCLUSIONS: There are various factors linked with stillbirths. It is important to track stillbirths to improve health outcomes of mothers and newborn. Further studies are necessary to analyse women empowerment factors to understand the linkages between empowerment and stillbirths

    Usability and acceptability of an automated respiratory rate counter to assess childhood pneumonia in Nepal

    No full text
    AIM: Pneumonia is the leading cause of child death after the neonatal period, resulting from late care seeking and inappropriate treatment. Diagnosis involves counting respiratory rate (RR); however, RR counting remains challenging for health workers and miscounting, and misclassification of RR is common. We evaluated the usability of a new automated RR counter, the Philips Children's Respiratory Monitor (ChARM), to Female Community Health Volunteers (FCHVs), and its acceptability to FCHVs and caregivers in Nepal. METHODS: A cross-sectional study was conducted in Jumla district, Nepal. About 133 FCHVs were observed between September and December 2018 when using ChARM during 517 sick child consultations, 264 after training and 253 after 2 months of routine use of ChARM. Acceptability of the ChARM was explored using semi-structured interviews. RESULTS: FCHV adherence to guidelines after 2 months of using ChARM routinely was 52.8% (95% CI 46.6-58.9). The qualitative findings suggest that ChARM is acceptable to FCHVs and caregivers; however, capacity constraints such as older age and low literacy and impacted device usability were mentioned. CONCLUSION: Further research on the performance, cost-effectiveness and implementation feasibility of this device is recommended, especially among low-literate CHWs
    corecore