15 research outputs found
Museum Guide
Ubiquitous computing is a concept in software engineering and computer science where computing is made to appear anytime and everywhere. In contrast to desktop computing, ubiquitous computing can occur using any device, in any location, and in any format. The process of investigating digital devices for the purpose of generating evidence related to an incident under investigation is referred to as Museum Guide. The motivation of this project is to detect crimes committed against people in which the evidence exists on a computer the system attempts to address whether or not evidence for events defined by the investigator is present in the document�s collected from the suspect�s computer. We propose a novel subject based semantic approach that clusters all the documents into a set of overlapping clusters corresponding to one unique subject of interest entered by the investigator
AI Foundation Models for Weather and Climate: Applications, Design, and Implementation
Machine learning and deep learning methods have been widely explored in
understanding the chaotic behavior of the atmosphere and furthering weather
forecasting. There has been increasing interest from technology companies,
government institutions, and meteorological agencies in building digital twins
of the Earth. Recent approaches using transformers, physics-informed machine
learning, and graph neural networks have demonstrated state-of-the-art
performance on relatively narrow spatiotemporal scales and specific tasks. With
the recent success of generative artificial intelligence (AI) using pre-trained
transformers for language modeling and vision with prompt engineering and
fine-tuning, we are now moving towards generalizable AI. In particular, we are
witnessing the rise of AI foundation models that can perform competitively on
multiple domain-specific downstream tasks. Despite this progress, we are still
in the nascent stages of a generalizable AI model for global Earth system
models, regional climate models, and mesoscale weather models. Here, we review
current state-of-the-art AI approaches, primarily from transformer and operator
learning literature in the context of meteorology. We provide our perspective
on criteria for success towards a family of foundation models for nowcasting
and forecasting weather and climate predictions. We also discuss how such
models can perform competitively on downstream tasks such as downscaling
(super-resolution), identifying conditions conducive to the occurrence of
wildfires, and predicting consequential meteorological phenomena across various
spatiotemporal scales such as hurricanes and atmospheric rivers. In particular,
we examine current AI methodologies and contend they have matured enough to
design and implement a weather foundation model.Comment: 44 pages, 1 figure, updated Fig.
Pleural effusion guidelines from ICS and NCCP Section 1: Basic principles, laboratory tests and pleural procedures
Pleural effusion is a common problem in our country, and most of these patients need invasive tests as they can’t be evaluated by blood tests alone. The simplest of them is diagnostic pleural aspiration, and diagnostic techniques such as medical thoracoscopy are being performed more frequently than ever before. However, most physicians in India treat pleural effusion empirically, leading to delays in diagnosis, misdiagnosis and complications from wrong treatments. This situation must change, and the adoption of evidence-based protocols is urgently needed. Furthermore, the spectrum of pleural disease in India is different from that in the West, and yet Western guidelines and algorithms are used by Indian physicians. Therefore, India-specific consensus guidelines are needed. To fulfil this need, the Indian Chest Society and the National College of Chest Physicians; the premier societies for pulmonary physicians came together to create this National guideline. This document aims to provide evidence based recommendations on basic principles, initial assessment, diagnostic modalities and management of pleural effusions
Recommended from our members
Long-term treatment with responsive brain stimulation in adults with refractory partial seizures.
OBJECTIVE: The long-term efficacy and safety of responsive direct neurostimulation was assessed in adults with medically refractory partial onset seizures. METHODS: All participants were treated with a cranially implanted responsive neurostimulator that delivers stimulation to 1 or 2 seizure foci via chronically implanted electrodes when specific electrocorticographic patterns are detected (RNS System). Participants had completed a 2-year primarily open-label safety study (n = 65) or a 2-year randomized blinded controlled safety and efficacy study (n = 191); 230 participants transitioned into an ongoing 7-year study to assess safety and efficacy. RESULTS: The average participant was 34 (±11.4) years old with epilepsy for 19.6 (±11.4) years. The median preimplant frequency of disabling partial or generalized tonic-clonic seizures was 10.2 seizures a month. The median percent seizure reduction in the randomized blinded controlled trial was 44% at 1 year and 53% at 2 years (p < 0.0001, generalized estimating equation) and ranged from 48% to 66% over postimplant years 3 through 6 in the long-term study. Improvements in quality of life were maintained (p < 0.05). The most common serious device-related adverse events over the mean 5.4 years of follow-up were implant site infection (9.0%) involving soft tissue and neurostimulator explantation (4.7%). CONCLUSIONS: The RNS System is the first direct brain responsive neurostimulator. Acute and sustained efficacy and safety were demonstrated in adults with medically refractory partial onset seizures arising from 1 or 2 foci over a mean follow-up of 5.4 years. This experience supports the RNS System as a treatment option for refractory partial seizures. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that for adults with medically refractory partial onset seizures, responsive direct cortical stimulation reduces seizures and improves quality of life over a mean follow-up of 5.4 years
Brain-responsive neurostimulation in patients with medically intractable mesial temporal lobe epilepsy.
OBJECTIVE: Evaluate the seizure-reduction response and safety of mesial temporal lobe (MTL) brain-responsive stimulation in adults with medically intractable partial-onset seizures of mesial temporal lobe origin.
METHODS: Subjects with mesial temporal lobe epilepsy (MTLE) were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events.
RESULTS: There were 111 subjects with MTLE; 72% of subjects had bilateral MTL onsets and 28% had unilateral onsets. Subjects had one to four leads placed; only two leads could be connected to the device. Seventy-six subjects had depth leads only, 29 had both depth and strip leads, and 6 had only strip leads. The mean follow-up was 6.1 ± (standard deviation) 2.2 years. The median percent seizure reduction was 70% (last observation carried forward). Twenty-nine percent of subjects experienced at least one seizure-free period of 6 months or longer, and 15% experienced at least one seizure-free period of 1 year or longer. There was no difference in seizure reduction in subjects with and without mesial temporal sclerosis (MTS), bilateral MTL onsets, prior resection, prior intracranial monitoring, and prior vagus nerve stimulation. In addition, seizure reduction was not dependent on the location of depth leads relative to the hippocampus. The most frequent serious device-related adverse event was soft tissue implant-site infection (overall rate, including events categorized as device-related, uncertain, or not device-related: 0.03 per implant year, which is not greater than with other neurostimulation devices).
SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including patients with unilateral or bilateral MTLE who are not candidates for temporal lobectomy or who have failed a prior MTL resection
Brain-responsive neurostimulation in patients with medically intractable seizures arising from eloquent and other neocortical areas.
OBJECTIVE: Evaluate the seizure-reduction response and safety of brain-responsive stimulation in adults with medically intractable partial-onset seizures of neocortical origin.
METHODS: Patients with partial seizures of neocortical origin were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. Additional analyses considered safety and seizure reduction according to lobe and functional area (e.g., eloquent cortex) of seizure onset.
RESULTS: There were 126 patients with seizures of neocortical onset. The average follow-up was 6.1 implant years. The median percent seizure reduction was 70% in patients with frontal and parietal seizure onsets, 58% in those with temporal neocortical onsets, and 51% in those with multilobar onsets (last observation carried forward [LOCF] analysis). Twenty-six percent of patients experienced at least one seizure-free period of 6 months or longer and 14% experienced at least one seizure-free period of 1 year or longer. Patients with lesions on magnetic resonance imaging (MRI; 77% reduction, LOCF) and those with normal MRI findings (45% reduction, LOCF) benefitted, although the treatment response was more robust in patients with an MRI lesion (p = 0.02, generalized estimating equation [GEE]). There were no differences in the seizure reduction in patients with and without prior epilepsy surgery or vagus nerve stimulation. Stimulation parameters used for treatment did not cause acute or chronic neurologic deficits, even in eloquent cortical areas. The rates of infection (0.017 per patient implant year) and perioperative hemorrhage (0.8%) were not greater than with other neurostimulation devices.
SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including adults with seizures of neocortical onset, and those with onsets from eloquent cortex