4 research outputs found

    Placement of a Viabahn stent-graft for hepatic artery pseudoaneurysm complicated by arterial dissection caused by a guiding sheath

    No full text
    A 69-year-old man was transferred to our hospital for massive hemorrhage from a right hepatic artery pseudoaneurysm 5 months after surgery for gastric cancer. Stent-graft placement was planned to avoid fatal hepatic infarction, and a guiding sheath was advanced deeply into the tortuous and stenotic right hepatic artery beyond the pseudoaneurysm for safe deployment of a stent-graft. However, this advancement caused arterial dissection of the right hepatic artery. After the guiding sheath was pulled back, a Viabahn stent-graft was successfully advanced over a guidewire to exclude the pseudoaneurysm. We consider that a Viabahn stent-graft is more flexible than a guiding sheath and that advancing a Viabahn stent-graft directly from a proximally placed guiding sheath is safer than advancing a guiding sheath into a tortuous and stenotic abdominal artery. Keywords: Stent-graft, Pseudoaneurysm, Arterial dissectio

    Usefulness of a distal access catheter in embolization of a short gastric artery pseudoaneurysm

    No full text
    A 59-year-old man was admitted to our hospital for hematemesis. A hematoma was found in the posterior wall of the stomach, but the source of bleeding was not identified. One month later, contrast-enhanced computed tomography revealed a pseudoaneurysm in the short gastric artery. Embolization of the pseudoaneurysm was difficult due to vessel tortuosity. Usage of a distal access catheter improved catheter stability and enabled successful embolization. We consider a distal access catheter to be useful for embolization of an aneurysm beyond a tortuous artery. Keywords: Short gastric artery, Pseudoaneurysm, Embolization, Distal access cathete

    Loop formation by an aortic occlusion balloon catheter during resuscitative endovascular balloon occlusion of the aorta (REBOA)

    No full text
    A 77-year-old man was transferred to our hospital for endoscopically uncontrollable active bleeding from a duodenal ulcer. Soon after his arrival, he became hemodynamically unstable and resuscitative endovascular balloon occlusion of the aorta was performed using a 7-F aortic occlusion balloon catheter (Rescue Balloon; Tokai Medical Products, Aichi, Japan). He became hemodynamically stable and was transferred to the CT room. CT demonstrated that the distal part of the catheter shaft had made a loop in the aorta and the balloon was located at the level of the upper abdomen. We consider the low-profile occlusion balloon catheter to be less rigid than large ones, and care should be taken to prevent balloon migration and catheter shaft bending. Keywords: Resuscitative endovascular balloon occlusion of the aorta, Aortic occlusion balloon cathete

    Successful embolization of ileal conduit stomal varices with N-butyl cyanoacrylate via a recanalized paraumbilical vein

    No full text
    A 77-year-old woman with liver cirrhosis was admitted to our hospital for marked hemorrhage in her ileal conduit stoma. She had a history of cystectomy and urinary diversion for bladder carcinoma 2 years ago. Contrast-enhanced CT demonstrated varices in the ileal conduit stoma. We accessed the varices via a recanalized paraumbilical vein to avoid pain from the transhepatic approach, and selectively embolized the varices with N-butyl cyanoacrylate (NBCA). We consider antegrade embolization of ileal conduit stomal varices with NBCA to be effective and feasible. Access via a paraumbilical vein is a useful alternative to the transhepatic approach. Keywords: Ectopic varix, Portal hypertension, Embolization, N-butyl cyanoacrylate, Paraumbilical vei
    corecore