18 research outputs found

    Matrix Metalloproteinase-1 and -9 in Human Placenta during Spontaneous Vaginal Delivery and Caesarean Sectioning in Preterm Pregnancy

    Get PDF
    Preterm birth is a major public health problem in terms of loss of life, long-term and short term disabilities worldwide. The process of parturition (both term and preterm) involves intensive remodelling of the extracellular matrix (ECM) in the placenta and fetal membranes by matrix metalloproteinases (MMPs). Our previous studies show reduced docosahexaenoic acid (DHA) in women delivering preterm. Further omega 3 fatty acids are reported to regulate MMP levels. This study was undertaken to examine the placental levels of MMPs and their association with placental DHA levels in women delivering preterm. The levels of MMP-1 and MMP-9 in 74 women delivering preterm (52 by spontaneous vaginal delivery and 22 by caesarean sectioning) and 75 women delivering at term (59 by spontaneous vaginal delivery and 16 by caesarean sectioning) were determined by enzyme-linked immunosorbent assay (ELISA) and their association with placental DHA was studied. Placental MMP-1 levels were higher (p<0.05) in women delivering preterm (both by spontaneous vaginal delivery and caesarean sectioning) as compared to those delivering at term. In contrast, placental MMP-9 levels in preterm pregnancies was higher (p<0.05) in women with spontaneous vaginal delivery while lower (p<0.05) in women delivering by caesarean sectioning. Low placental DHA was associated with higher placental MMP-9 levels. Our study suggests a differential effect of mode of delivery on the levels of MMPs from placenta. Further this study suggests a negative association of DHA and the levels of MMP-9 in human placenta although the mechanisms need further study

    Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries

    Get PDF
    Purpose: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. Methods: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0&nbsp;–&nbsp;8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Results: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9&nbsp;% of the patients, and a PET study in 2.1&nbsp;%. The average effective dose of SPECT was 8.0 ± 3.4&nbsp;mSv (RoW 11.4 ± 4.3&nbsp;mSv; P &lt; 0.001) and of PET was 2.6 ± 1.5&nbsp;mSv (RoW 3.8 ± 2.5&nbsp;mSv; P &lt; 0.001). The mean effective doses of SPECT and PET differed between European regions (P &lt; 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P &lt; 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. Conclusion: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice

    Current worldwide nuclear cardiology practices andradiationexposure: results from the 65 country IAEA nuclear cardiology protocols cross-sectional study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiationoptimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposurewere identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally

    Evidence of spread of the emerging infectious disease, finch trichomonosis, by migrating birds

    Full text link
    Finch trichomonosis emerged in Great Britain in 2005 and led to epidemic mortality and a significant population decline of greenfinches, Carduelis chloris and chaffinches, Fringilla coelebs, in the central and western counties of England and Wales in the autumn of 2006. In this article, we show continued epidemic spread of the disease with a pronounced shift in geographical distribution towards eastern England in 2007. This was followed by international spread to southern Fennoscandia where cases were confirmed at multiple sites in the summer of 2008. Sequence data of the ITS1/5.8S/ITS2 ribosomal region and part of the small subunit (SSU) rRNA gene showed no variation between the British and Fennoscandian parasite strains of Trichomonas gallinae. Epidemiological and historical ring return data support bird migration as a plausible mechanism for the observed pattern of disease spread, and suggest the chaffinch as the most likely primary vector. This finding is novel since, although intuitive, confirmed disease spread by migratory birds is very rare and, when it has been recognised, this has generally been for diseases caused by viral pathogens. We believe this to be the first documented case of the spread of a protozoal emerging infectious disease by migrating birds
    corecore