2,405 research outputs found
Classical and Quantum Cosmology of Multigravity
Recently, a multigraviton theory on a simple closed circuit graph
corresponding to the discretization of compactification of the
Kaluza-Klein (KK) theory has been considered. In the present paper, we extend
this theory to that on a general graph and study what modes of particles are
included. Furthermore, we generalize it in a possible nonlinear theory based on
the vierbein formalism and study classical and quantum cosmological solutions
in the theory. We found that scale factors in a solution for this theory repeat
acceleration and deceleration.Comment: 17 pages, 15 figures, RevTeX4.1, revised versio
Irreducible characters of GSp(4, q) and dimensions of spaces of fixed vectors
In this paper, we compute the conjugacy classes and the list of irreducible
characters of GSp(4,q), where q is odd. We also determine precisely which
irreducible characters are non-cuspidal and which are generic. These characters
are then used to compute dimensions of certain subspaces of fixed vectors of
smooth admissible non-supercuspidal representations of GSp(4,F), where F is a
non-archimedean local field of characteristic zero with residue field of order
q.Comment: 48 pages, 21 tables. Corrected an error in Table 16 for type V*
representations (theta_11 and theta_12 were switched
Surface MIMO: Using Conductive Surfaces For MIMO Between Small Devices
As connected devices continue to decrease in size, we explore the idea of
leveraging everyday surfaces such as tabletops and walls to augment the
wireless capabilities of devices. Specifically, we introduce Surface MIMO, a
technique that enables MIMO communication between small devices via surfaces
coated with conductive paint or covered with conductive cloth. These surfaces
act as an additional spatial path that enables MIMO capabilities without
increasing the physical size of the devices themselves. We provide an extensive
characterization of these surfaces that reveal their effect on the propagation
of EM waves. Our evaluation shows that we can enable additional spatial streams
using the conductive surface and achieve average throughput gains of 2.6-3x for
small devices. Finally, we also leverage the wideband characteristics of these
conductive surfaces to demonstrate the first Gbps surface communication system
that can directly transfer bits through the surface at up to 1.3 Gbps.Comment: MobiCom '1
Similarity In Phase Diagrams Between Ionic And Nonionic Surfactant Solutions At Constant Temperature
Ocean temperature and salinity components of the Madden-Julian oscillation observed by Argo floats
New diagnostics of the Madden-Julian Oscillation (MJO) cycle in ocean temperature and, for the first time, salinity are presented. The MJO composites are based on 4 years of gridded Argo float data from 2003 to 2006, and extend from the surface to 1,400 m depth in the tropical Indian and Pacific Oceans. The MJO surface salinity anomalies are consistent with precipitation minus evaporation fluxes in the Indian Ocean, and with anomalous zonal advection in the Pacific. The Argo sea surface temperature and thermocline depth anomalies are consistent with previous studies using other data sets. The near-surface density changes due to salinity are comparable to, and partially offset, those due to temperature, emphasising the importance of including salinity as well as temperature changes in mixed-layer modelling of tropical intraseasonal processes. The MJO-forced equatorial Kelvin wave that propagates along the thermocline in the Pacific extends down into the deep ocean, to at least 1,400 m. Coherent, statistically significant, MJO temperature and salinity anomalies are also present in the deep Indian Ocean
Electroretinographic Evaluations Using Skin Electrode of Eyes with Bleb-Related Endophthalmitis Following Vitrectomy with 0.025% Povidone Iodine Irrigation
Koki Sakata, Takeshi Katsumoto, Tomoyuki Kumagai, Kei Shinoda Department of Ophthalmology, Saitama Medical University, Saitama, JapanCorrespondence: Kei Shinoda, Department of Ophthalmology, Saitama Medical University, 38 Morohongo, Moroyama, Saitama, 350-0495, Japan, Tel +81-4-9276-1250, Fax +81-4-9295-8002, Email [email protected]: To determine whether 0.025% povidone-iodine (0.025% PI) in the irrigation solution during vitrectomy for endophthalmitis is safe.Methods: Two cases of bleb-associated endophthalmitis were treated with vitrectomy using 0.025% PI in the irrigation solution. The RETevel electroretinographic (ERG) system with skin electrodes was used to assess the physiology of the retina pre- and postoperatively.Case: Case 1 was a 46-year-old man who had atopic keratoconjunctivitis and underwent trabeculectomy with the creation of a bleb after there was a rise in the intraocular pressure. One month postoperatively, a mild filtering bleb-associated endophthalmitis developed, and the eye was treated with intravitreal and subconjunctival injections of vancomycin (VCM) and ceftazidime (CAZ). After three days, the fundus was not visible and B-mode echography showed an area of high brightness in the retina. Vitrectomy with irrigation with VCM and CAZ, and 0.025% PI was performed successfully. Pre- and postoperative ERGs showed an improvement in both the a- and b-wave amplitudes and the b/a ratio was stable at 2.0. Case 2 was a 63-year-old man who had undergone trabeculectomy for glaucoma. Five years later, the eye developed blebitis which was treated with topical and subconjunctival injections of VCM and CAZ. Three days later, vitreous opacities appeared and a high brightness area was seen in the B-mode echographic images. Vitrectomy with VCM and CAZ, and 0.025% PI irrigation was successfully performed. Comparisons of the pre- and postoperative ERGs found that the a- and b- wave amplitudes of the ERGs increased and the b/a ratio was stable at approximately 1.5.Conclusion: Vitrectomy with 0.025% PI irrigation is safe and ERG recordings with skin electrodes can be used to evaluate the pre- and postoperative retinal physiology safely.Plain Language Summary: We report our findings in two cases of bleb-related endophthalmitis that underwent pars plana vitrectomy (PPV) with irrigation with 0.025% povidone-iodine (PI)-Balanced Salt Solution (BSS) PLUS (Alcon Laboratories, Fort Worth, TX). The retinal function was evaluated by full-field electroretinograms (ERGs) recorded with skin electrodes before and after the vitrectomy.At present, there is no consensus on whether patients with bleb-related endophthalmitis should be treated with PPV or treated solely by intravitreal antibiotics. It was recently reported that vitrectomy using an irrigation solution containing 0.025% PI followed by postoperative antibiotics was effective and safe for the treatment of endogenous endophthalmitis and postoperative endophthalmitis. However, iodine is known to be retinotoxic depending on its concentration.Electroretinography is a useful method to evaluate the safety of medications because it represents the physiology of the entire retina. However, conventional recording procedures with contact lens electrodes cannot be used in eyes with bleb associated endophthalmitis. Therefore, we performed ERG using skin electrodes which were introduced relatively recently. As a result, electroretinographic response showed that retinal function was not altered after surgery in these two cases.Keywords: blebitis, electroretinography, bleb-related endophthalmitis, povidone iodine irrigation, vitrectom
Recent X-ray measurements of the accretion-powered pulsar 4U 1907+09
X-ray observations of the accreting X-ray pulsar 4U~1907+09, obtained during
February 1996 with the Proportional Counter Array on the Rossi X-ray Timing
Experiment (RXTE), have enabled the first measurement of the intrinsic pulse
period Ppulse since 1984: Ppulse=440.341[+0.012,-0.017] s. 4U 1907+09 is in a
binary system with a blue supergiant. The orbital parameters were solved and
this enabled the correction for orbital delay effects of a measurement of
Ppulse obtained in 1990 with Ginga. Thus, three spin down rates could be
extracted from four pulse periods obtained in 1983, 1984, 1990, and 1996. These
are within 8% equal to a value of dPpulse/dt=+0.225 s/yr. This suggest that the
pulsar is perhaps in a monotonous spin down mode since its discovery in 1983.
Furthermore, the RXTE observations show transient ~18 s oscillations during a
flare that lasted about 1 hour. The oscillations may be interpreted as
Keplerian motion of an accretion disk near the magnetospheric radius. This, and
the notion that the co-rotation radius is much larger than any conceivable
value for the magnetospheric radius (because of the long spin period), renders
it unlikely that this pulsar spins near equilibrium like is suspected for other
slowing accreting X-ray pulsars. We suggest as an alternative that perhaps the
frequent occurrence of a retrograde transient accretion disk may be
consistently slowing the pulsar down. Further observations of flares can
provide more evidence of this.Comment: 26 pages, 11 figures, to be published in Astrophysical Journal part I
on March 20, 199
Sonic-Point Model of Kilohertz Quasi-Periodic Brightness Oscillations in Low-Mass X-ray Binaries
Strong, coherent, quasi-periodic brightness oscillations (QPOs) with
frequencies ranging from about 300 Hz to 1200 Hz have been discovered with the
Rossi X-ray Timing Explorer in the X-ray emission from some fifteen neutron
stars in low-mass binary systems. Two simultaneous kilohertz QPOs differing in
frequency by 250 to 350 Hertz have been detected in twelve of the fifteen
sources. Here we propose a model for these QPOs. In this model the X-ray source
is a neutron star with a surface magnetic field of 10^7 to 10^10 G and a spin
frequency of a few hundred Hertz, accreting gas via a Keplerian disk. The
frequency of the higher-frequency QPO in a kilohertz QPO pair is the Keplerian
frequency at a radius near the sonic point at the inner edge of the Keplerian
flow whereas the frequency of the lower-frequency QPO is approximately the
difference between the Keplerian frequency at a radius near the sonic point and
the stellar spin frequency. This model explains naturally many properties of
the kilohertz QPOs, including their frequencies, amplitudes, and coherence. We
show that if the frequency of the higher-frequency QPO in a pair is an orbital
frequency, as in the sonic-point model, the frequencies of these QPOs place
interesting upper bounds on the masses and radii of the neutron stars in the
kilohertz QPO sources and provide new constraints on the equation of state of
matter at high densities. Further observations of these QPOs may provide
compelling evidence for the existence of a marginally stable orbit, confirming
a key prediction of general relativity in the strong-field regime.Comment: 67 pages, including 15 figures and 5 tables; uses aas2pp4; final
version to appear in the Astrophysical Journal on 1 December 199
Measurement of the cosmic-ray antiproton spectrum at solar minimum with a long-duration balloon flight over Antarctica
The energy spectrum of cosmic-ray antiprotons from 0.17 to 3.5 GeV has been
measured using 7886 antiprotons detected by BESS-Polar II during a
long-duration flight over Antarctica near solar minimum in December 2007 and
January 2008. This shows good consistency with secondary antiproton
calculations. Cosmologically primary antiprotons have been investigated by
comparing measured and calculated antiproton spectra. BESS-Polar II data show
no evidence of primary antiprotons from evaporation of primordial black holes.Comment: 4 pages, 4 figures, submitted to Physical Review Letter
- …