749 research outputs found

    Directional Sensitivity of Echolocation System in Bats Producing Frequency-Modulated Signals

    Get PDF
    1. Radiation patterns of the 55, 75 and 95 kHz components in frequency-modulated sounds emitted by the grey bat (Myotis grisescens) were studied. FM sounds similar to species-specific orientation sounds were elicited by electrical stimuli applied to the midbrain while the head of the animal was immobilized by a nail cemented to its skull. The main beam was emitted 5-10° downward from the eye-nostril line. The radiation angle at one half of maximum amplitude was 38° lateral, 18° up and 50° down at 55 kHz, 34° lateral, 8° up and 32° down at 75 kHz, and 30° lateral, 5° up and 25° down at 95 kHz. At 95 kHz, two prominent side lobes were present. 2. The directional sensitivity of the auditory system (DSA) measured in terms of the potential evoked in the lateral lemniscus was studied with the grey bat (M. grisescens) and the little brown bat (M. lucifugus). The maximally sensitive direction moved toward the median plane with the increase in frequency from 35-95 kHz. The slope of the DSA curve increased from 0.3-0.6 dB/degree with frequency. 3. The directional sensitivity of the echolocation system (DSE) was calculated using both the DSA curve and the radiation pattern of the emitted sound. The maximally sensitive direction of the echolocation system was 15° lateral to the median plane at 55kHz and 2.5° lateral at 95 kHz. The slope of the DSE curve increased from o.6 to 1.0 dB/degree with frequency. Thus, the higher the frequency of sound, the sharper was the directional sensitivity of the echolocation system. 4. The interaural pressure difference (IPD), which appeared to be the essential cue for echolocation in Myotis, changed linearly with the azimuth angle from 0-30° lateral regardless of the frequency of sound, at respective rates of 0.4, 0.7, 0.3 and 0.4 dB/degree for 35, 55, 75 and 95 kHz sounds. Beyond 30°, the change in IPD was quite different depending on frequency. For 75 and 95 kHz sounds, the IPD stayed nearly the same between 30° and 90°. Thus, the 75-95 kHz components in FM orientation sounds were not superior to the 35 and 55 kHz components in terms of the IPD cue for echolocation. 5. Assuming the just-detectable IPD and ITD to be 0.5 dB and 5µsec respectively, as in man, the just-detectable azimuth difference of Myotis around the median plane would be 0.7-1.7° with the IPD cue and 11° with the ITD cue

    Lens surgeries along the nn-twisted Whitehead link

    Full text link
    We determine lens surgeries (i.e.\ Dehn surgery yielding a lens space) along the nn-twisted Whitehead link. To do so, we first give necessary conditions to yield a lens space from the Alexander polynomial of the link as: (1) n=1n=1 (i.e. the Whitehead link), and (2) one of surgery coefficients is 1, 2 or 3. Our interests are not only lens surgery itself but also how to apply the Alexander polynomial for this kind of problems.Comment: 24 pages, 5 figure

    Sarcomere Imaging by Quantum Dots for the Study of Cardiac Muscle Physiology

    Get PDF
    We here review the use of quantum dots (QDs) for the imaging of sarcomeric movements in cardiac muscle. QDs are fluorescence substances (CdSe) that absorb photons and reemit photons at a different wavelength (depending on the size of the particle); they are efficient in generating long-lasting, narrow symmetric emission profiles, and hence useful in various types of imaging studies. Recently, we developed a novel system in which the length of a particular, single sarcomere in cardiomyocytes can be measured at ~30 nm precision. Moreover, our system enables accurate measurement of sarcomere length in the isolated heart. We propose that QDs are the ideal tool for the study of sarcomere dynamics during excitation-contraction coupling in healthy and diseased cardiac muscle
    corecore