26 research outputs found

    A novel mathematical model of activation and sensitization of platelets subjected to dynamic stress histories

    Get PDF
    Abstract Blood recirculating devices, such as ventricular assist devices and prosthetic heart valves, are burdened by thromboembolic complications requiring complex and lifelong anticoagulant therapy with its inherent hemorrhagic risks. Pathologic flow patterns occurring in such devices chronically activate platelets, and the optimization of their thrombogenic performance requires the development of flow-induced platelet activation models. However, existing models are based on empirical correlations using the wellestablished power law paradigm of constant levels of shear stress during certain exposure times as factors for mechanical platelet activation. These models are limited by their range of application and do not account for other relevant phenomena, such as loading rate dependence and platelet sensitization to high stress conditions, which characterize the dynamic flow conditions in devices. These limitations were addressed by developing a new class of phenomenological stress-induced platelet activation models that specifies the rate of platelet activation as a function of the entire stress history and results in a differential equation that can be directly integrated to calculate the cumulative levels of activation. The proposed model reverts to the power law under constant shear stress conditions and is able to describe experimental results in response to a diverse range of highly dynamic stress conditions found in blood recirculating devices. The model was tested in vitro under emulated device flow conditions and correlates well with experimental results. This new model provides a reliable and robust mathematical tool that can be incorporated into computational fluid dynamic studies in order to optimize design, with the goal of improving the thrombogenic performance of blood recirculating devices

    Hemodynamic and thrombogenic analysis of a trileaflet polymeric valve using a fluid-structure interaction approach

    Get PDF
    Surgical valve replacement in patients with severe calcific aortic valve disease using either bioprosthetic or mechanical heart valves is still limited by structural valve deterioration for the former and thrombosis risk mandating anticoagulant therapy for the latter. Prosthetic polymeric heart valves have the potential to overcome the inherent material and design limitations of these valves, but their development is still ongoing. The aim of this study was to characterize the hemodynamics and thrombogenic potential of the Polynova polymeric trileaflet valve prototype using a fluid-structure interaction (FSI) approach. The FSI model replicated experimental conditions of the valve as tested in a left heart simulator. Hemodynamic parameters (transvalvular pressure gradient, flow rate, maximum velocity, and effective orifice area) were compared to assess the validity of the FSI model. The thrombogenic footprint of the polymeric valve was evaluated using a Lagrangian approach to calculate the stress accumulation (SA) values along multiple platelet trajectories and their statistical distribution. In the commissural regions, platelets were exposed to the highest SA values because of highest stress levels combined with local reverse flow patterns and vortices. Stress-loading waveforms from representative trajectories in regions of interest were emulated in our Hemodynamic Shearing Device (HSD). Platelet activity was measured using our platelet activation state (PAS) assay and the results confirmed the higher thrombogenic potential of the commissural hotspots. In conclusion, the proposed method provides an in depth analysis of the hemodynamic and thrombogenic performance of the polymer valve prototype and identifies locations for further design optimization

    Shear-Mediated Platelet Microparticles Demonstrate Phenotypic Heterogeneity as to Morphology, Receptor Distribution, and Hemostatic Function

    No full text
    Implantable Cardiovascular Therapeutic Devices (CTD), while lifesaving, impart supraphysiologic shear stress to platelets, resulting in thrombotic and bleeding coagulopathy. We previously demonstrated that shear-mediated platelet dysfunction is associated with downregulation of platelet GPIb-IX-V and 伪IIb尾3 receptors via generation of Platelet-Derived MicroParticles (PDMPs). Here, we test the hypothesis that sheared PDMPs manifest phenotypical heterogeneity of morphology and receptor surface expression and modulate platelet hemostatic function. Human gel-filtered platelets were exposed to continuous shear stress. Alterations of platelet morphology were visualized using transmission electron microscopy. Surface expression of platelet receptors and PDMP generation were quantified by flow cytometry. Thrombin generation was quantified spectrophotometrically, and platelet aggregation was measured by optical aggregometry. Shear stress promotes notable alterations in platelet morphology and ejection of distinctive types of PDMPs. Shear-mediated microvesiculation is associated with the remodeling of platelet receptors, with PDMPs expressing significantly higher levels of adhesion receptors (伪IIb尾3, GPIX, PECAM-1, P-selectin, and PSGL-1) and agonist receptors (P2Y12 and PAR1). Sheared PDMPs promote thrombin generation and inhibit platelet aggregation induced by collagen and ADP. Sheared PDMPs demonstrate phenotypic heterogeneity as to morphology and defined patterns of surface receptors and impose a bidirectional effect on platelet hemostatic function. PDMP heterogeneity suggests that a range of mechanisms are operative in the microvesiculation process, contributing to CTD coagulopathy and posing opportunities for therapeutic manipulation

    A review of Wells, R. & Gianetti, V. (1990). Handbook of Brief Psychotherapies, New York: Plenum

    Get PDF
    This handbook sets out to provide a comprehensive account of current knowledge on empirically grounded time-limited approaches to psychotherapy. The book contains 25 chapters divided into five sections. The first includes a series of essays on key topics such as theoretical integration, recent innovative approaches to process research, and the implications of mental health policy for brief therapy. The second section covers a number of technical issues such as managing engagement problems, using time limited contracts to promote change, setting tasks and single session therapy. The third, fourth and fifth sections contain review chapters on individual, family and group approaches to brief therapy. Within these chapters, psychodynamic, systems and cognitive-behavioural perspectives are well represented along with a number on interesting integrative approaches

    Routine clinical anti-platelet agents have limited efficacy in modulating hypershear-mediated platelet activation associated with mechanical circulatory support

    No full text
    Introduction: Continuous flow ventricular assist devices (cfVADs) continue to be limited by thrombotic complications associated with disruptive flow patterns and supraphysiologic shear stresses. Patients are prescribed complex antiplatelet therapies, which do not fully prevent recurrent thromboembolic events. This is partially due to limited data on antiplatelet efficacy under cfVAD-associated shear conditions. Materials and methods: We investigated the efficacy of antiplatelet drugs directly acting on three pathways: (1) cyclooxygenase (aspirin), (2) phosphodiesterase (dipyridamole, pentoxifylline, cilostazol), and (3) glycoprotein IIb-IIIa (eptifibatide). Gel-filtered platelets treated with these drugs were exposed for 10 min to either constant shear stresses (30 dyne/cm2and 70 dyne/cm2) or dynamic shear stress profiles extracted from simulated platelet trajectories through a cfVAD (Micromed DeBakey). Platelet activation state (PAS) was measured using a modified prothrombinase-based assay, with drug efficacy quantified based on PAS reduction compared to untreated controls. Results and conclusions: Significant PAS reduction was observed for all drugs after exposure to 30 dyne/cm2constant shear stress, and all drugs but dipyridamole after exposure to the 30th percentile shear stress waveform of the cfVAD. However, only cilostazol was significantly effective after 70 dyne/cm2constant shear stress exposure, though no significant reduction was observed upon exposure to median shear stress conditions in the cfVAD. These results, coupled with the persistence of reported clinical thrombotic complication, suggest the need for the development of new classes of drugs that are especially designed to mitigate thrombosis in cfVAD patients, while reducing or eliminating the risk of bleeding

    Thrombogenic potential of innovia polymer valves versus Carpentier-Edwards Perimount Magna Sortic Bioprosthetic Valves

    No full text
    Trileaflet polymeric prosthetic aortic valves (AVs) produce hemodynamic characteristics akin to the natural AV and may be most suitable for applications such as transcatheter implantation and mechanical circulatory support (MCS) devices. Their success has not yet been realized due to problems of calcification, durability, and thrombosis. We address the latter by comparing the platelet activation rates (PARs) of an improved polymer valve design (Innovia LLC) made from poly(styrene-block-isobutylene-block-styrene) (SIBS) with the commercially available Carpentier-Edwards Perimount Magna Aortic Bioprosthetic Valve. We used our modified prothrombinase platelet activity state (PAS) assay and flow cytometry methods to measure platelet activation of a pair of 19 mm valves mounted inside a pulsatile Berlin left ventricular assist device (LVAD). The PAR of the polymer valve measured with the PAS assay was fivefold lower than that of the tissue valve (p = 0.005) and fourfold lower with flow cytometry measurements (p = 0.007). In vitro hydrodynamic tests showed clinically similar performance of the Innovia and Magna valves. These results demonstrate a significant improvement in thrombogenic performance of the polymer valve compared with our previous study of the former valve design and encourage further development of SIBS for use in heart valve prostheses. Copyright 漏 American Society of Artificial Internal Organs

    Shear-Mediated Platelet Activation is Accompanied by Unique Alterations in Platelet Release of Lipids

    No full text
    Introduction: Platelet activation by mechanical means such as shear stress exposure, is a vital driver of thrombotic risk in implantable blood-contacting devices used in the treatment of heart failure. Lipids are essential in platelets activation and have been studied following biochemical activation. However, little is known regarding lipid alterations occurring with mechanical shear-mediated platelet activation. Methods: Here, we determined if shear-activation of platelets induced lipidome changes that differ from those associated with biochemically-mediated platelet activation. We performed high-resolution lipidomic analysis on purified platelets from four healthy human donors. For each donor, we compared the lipidome of platelets that were non-activated or activated by shear, ADP, or thrombin treatment. Results: We found that shear activation altered cell-associated lipids and led to the release of lipids into the extracellular environment. Shear-activated platelets released 21 phospholipids and sphingomyelins at levels statistically higher than platelets activated by biochemical stimulation. Conclusions: We conclude that shear-mediated activation of platelets alters the basal platelet lipidome. Further, these alterations differ and are unique in comparison to the lipidome of biochemically activated platelets. Many of the released phospholipids contained an arachidonic acid tail or were phosphatidylserine lipids, which have known procoagulant properties. Our findings suggest that lipids released by shear-activated platelets may contribute to altered thrombosis in patients with implanted cardiovascular therapeutic devices. 漏 2021, Biomedical Engineering Society.Arizona Biomedical Research Commission12 month embargo; published: 25 August 2021This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]
    corecore