11 research outputs found

    Data-independent proteomic screen identifies novel tamoxifen agonist that mediates drug resistance

    Get PDF
    A label-free quantitative variation of the recently developed data-independent shotgun proteomic method Precursor Acquisition Independent From Ion Count (PAcIFIC) was used to identify novel proteins implicated in cancer progression and resistance. Specifically, this screen identified the pro-metastatic protein anterior gradient 2 (AGR2) as significantly up-regulated in tamoxifen treated cells. Highlighting the need for direct proteome profiling methods like PAcIFIC, neither data-dependent gas-phase fractionation nor a transcriptomic screen detected AGR2 protein/transcript at significantly up-regulated levels. Further cell-based experiments using human cancer cell lines and in vivo xenografts confirmed the PAcIFIC hypothesis that AGR2 is up-regulated in MCF-7 cells post tamoxifen treatment, and that it is implicated in drug resistance mediation

    Urinary Excretion of 3-Hydroxyisovaleryl Carnitine Is an Early and Sensitive Indicator of Marginal Biotin Deficiency in Humans12

    Full text link
    Mounting evidence indicates that marginal biotin deficiency is not rare, contrary to previous assumptions. Accordingly, robust indicators of biotin status would be useful. In a study of 10 healthy adults, we recently provided evidence that abnormally increased plasma concentration of 3-hydroxyisovaleryl carnitine (3HIA-carnitine) is a sensitive indicator of marginal biotin deficiency. We sought to determine whether urinary excretion of 3HIA-carnitine (expressed as the ratio to urinary creatinine) significantly increases in marginal biotin deficiency. Marginal, asymptomatic biotin deficiency was induced experimentally in the same 10 healthy adults (8 women) by feeding undenatured egg white with meals for 28 d. Biotin status was repleted by a mixed general diet plus biotin supplementation. Urinary excretion of 3HIA-carnitine was determined by liquid chromatography-tandem MS on d 0, 14, and 28 (depletion) and on d 35 and 50 (repletion). Mean urinary 3HIA-carnitine concentration increased with depletion (P < 0.0001; d 0 vs. 28) and decreased with repletion (P = 0.0002; d 28 vs. 50). Urinary 3HIA-carnitine excretion was greater than the upper limit of normal in 9 of 10 participants by d 14 and decreased to within normal limits by d 50 in all participants. This study provides evidence that urinary excretion of 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of collection of untimed urine samples and application of a new analytical method with simplified sample preparation suggest that urinary 3HIA-carnitine is likely to be a useful indicator for large population studies

    Plasma concentration of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans1234

    Full text link
    Background: Blood-based indicators of biotin status in humans were shown to be useful tools in several clinical situations, including pregnancy. We previously validated the activity of the biotin-dependent enzyme propionyl-coenzyme A carboxylase (PCC) in lymphocytes as a sensitive and specific blood-based indicator of marginal degrees of biotin deficiency. However, the measurement of PCC activity in population studies presents substantial analytic challenges. 3-Hydroxyisovaleryl carnitine (3HIA-carnitine) increases in response to the decreased activity of the biotin-dependent enzyme methylcrotonyl-coenzyme A carboxylase and might reflect biotin status
    corecore