24 research outputs found

    Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time

    Get PDF
    Purpose Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS). Methods For twenty patients, an optimizer for automated multi-criterial planning with integrated beam angle optimization (BAO) was used to generate dual-arc VMAT plans, supplemented with five non-coplanar IMRT beams with individually optimized orientations (VMAT+5). In all plan generations, reduction of high rectum dose had the highest priority after obtaining adequate PTV coverage. A CS with two most preferred directions in VMAT+5 and largest rectum dose reductions compared to dual-arc VMAT was then selected to define VMAT+CS. VMAT+CS was compared with automatically generated i) dual-arc coplanar VMAT plans (VMAT), ii) VMAT+5 plans, and iii) IMRT plans with 30 patient-specific non-coplanar beam orientations (30-NCP). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Differences in PTV doses, healthy tissue sparing, and computation and treatment delivery times were quantified. Results For equal PTV coverage, VMAT+CS, consisting of dual-arc VMAT supplemented with two fixed, non-coplanar IMRT beams with fixed Gantry/Couch angles of 65 degrees/30 degrees and 295 degrees/-30 degrees, significantly reduced OAR doses and the dose bath, compared to dual-arc VMAT. Mean relative differences in rectum D-mean, D-1cc, V-40GyEq and V-60GyEq were 19.4 +/- 10.6%, 4.2 +/- 2.7%, 34.9 +/- 20.3%, and 39.7 +/- 23.2%, respectively (all p Conclusions The proposed two-beam non-coplanar class solution to complement coplanar dual-arc VMAT resulted in substantial plan quality improvements for OARs (especially rectum) and reduced irradiated patient volumes with minor increases in treatment delivery times

    First fully automated planning solution for robotic radiosurgery - comparison with automatically planned volumetric arc therapy for prostate cancer

    Get PDF
    Background: For conventional radiotherapy treatment units, automated planning can significantly improve plan quality. For robotic radiosurgery, systems for automatic generation of clinically deliverable plans do not yet exist. For prostate stereotactic body radiation therapy (SBRT), few studies have systematically compared VMAT with robotic treatment. Material and methods: The multi-criteria autoplanning optimizer, developed at our institute, was coupled to the commercial treatment planning system of our robotic treatment unit, for fully automated generation of clinically deliverable plans (autoROBOT). The system was then validated by comparing autoROBOT plans with manually generated plans. Next, the autoROBOT system was used for systematic comparisons between autoROBOT plans and VMAT plans, that were also automatically generated (autoVMAT). CTV-PTV margins of 3 mm were used for autoROBOT (clinical routine) and autoVMAT plan generation. For autoVMAT, an extra plan was generated with 5 mm margin (often applied for VMAT). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Results: Compared to manual planning, autoROBOT improved rectum D (16%), V (75%) and D (41%), and bladder D (37%) (all p .002), with equal PTV coverage. In the autoROBOT and autoVMAT comparison, both with 3 mm margin, rectum doses were lower for autoROBOT by 5% for rectum D (p=.002), 33% for V (p=.001) and 4% for D (p=.05), with comparable PTV coverage and other OAR sparing. With 5 mm margin for VMAT, 18/20 plans had a PTV coverage lower than requested

    The impact of bone marrow sparing on organs at risk dose for cervical cancer:a Pareto front analysis

    Get PDF
    Background and purpose: To quantify the increase in bladder and rectum dose of a bone marrow sparing (BMS) VMAT strategy for primary treatment of locally advanced cervical cancer (LACC). Materials and methods: Twenty patients with stage IB-IVA cervical cancer were selected for this study. The whole Pelvic Bones (PB) was taken as substitute for bone marrow. For every patient, Pareto-optimal plans were generated to explore the trade-off between rectum, bladder, and PB mean dose. The PB mean dose was decreased in steps of 1 Gy. For each step, the increase in rectum and bladder mean dose was quantified. The increase in mean dose of other OAR compared to no BMS was constrained to 1 Gy. Results: In total, 931 plans of 19 evaluable patients were analyzed. The average [range] mean dose of PB without BMS was 22.8 [20.7-26.2] Gy. When maximum BMS was applied, the average reduction in mean PB dose was 5.4 [3.0-6.8] Gy resulting in an average mean PB dose of 17.5 [15.8-19.8] Gy. For &lt;1 Gy increase in both the bladder and the rectum mean dose, the PB mean dose could be decreased by &gt;2 Gy, &gt;3 Gy, &gt;4 Gy, and &gt;5 Gy for 19/19, 13/19, 5/19, and 1/19 patients, respectively. Conclusion: Based on the comprehensive three-dimensional Pareto front analysis, we conclude that 2-5 Gy BMS can be implemented without a clinically relevant increase in mean dose to other OAR. If BMS is too dominant, it results in a large increase in mean dose to other OAR. Therefore, we recommend implementing moderate BMS for the treatment of LACC patients with VMAT.</p

    Validation of fully automated VMAT plan generation for library-based plan-of-the-day cervical cancer radiotherapy

    Get PDF
    Purpose: To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer. Material and Methods: Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid. Results: All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p<0.001). For 41/44 autoVMAT plans, SB V45Gy was lower than for manVMAT (p<0.001, average reduction 30.3%), while SB V15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs. sponsored the appointment of STH for this project. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Conclusions: Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible

    Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation

    Get PDF
    _Background:_ Planning for Volumetric Modulated Arc Therapy (VMAT) may be time consuming and its use is limited by available staff resources. Automated multicriterial treatment planning can eliminate this bottleneck. We compared automatically created (auto) VMAT plans generated by Erasmus-iCycle to manually created VMAT plans for treatment of spinal metastases. _Methods:_ Forty-two targets in 32 patients were analyzed. Lungs and kidneys were defined as organs at risk (OARs). Twenty-two patients received radiotherapy on kidney levels, 17 on lung levels, and 3 on both levels. _Results:_ All Erasmus-iCycle plans were clinically acceptable. When compared to manual plans, planning target volume (PTV) coverage of auto plans was significantly better. The Homogeneity Index did not differ significantly between the groups. Mean dose to OARs was lower in auto plans concerning both kidneys and the left lung. One hotspot (>110% of D50%) occurred in the spinal cord of one auto plan (33.2 Gy, D50%: 30 Gy). Treatment time was 7% longer in auto plans. _Conclusions:_ Erasmus-iCycle plans showed better target coverage and sparing of OARs at the expense of minimally longer treatment times (for which no constraint was set)

    Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer

    Get PDF
    Background: Postoperative/adjuvant radiotherapy of advanced gastric cancer involves a large planning target volume (PTV) with multi-concave shapes which presents a challenge for volumetric modulated arc therapy (VMAT) planning. This study investigates the advantages of automated VMAT planning for this site compared to manual VMAT planning by expert planners. Methods: For 20 gastric cancer patients in the postoperative/adjuvant setting, dual-arc VMAT plans were generated using fully automated multi-criterial treatment planning (autoVMAT), and compared to manually generated VMAT plans (manVMAT). Both automated and manual plans were created to deliver a median dose of 45 Gy to the PTV using identical planning and segmentation parameters. Plans were evaluated by two expert radiation oncologists for clinical acceptability. AutoVMAT and manVMAT plans were also compared based on dose-volume histogram (DVH) and predicted normal tissue complication probability (NTCP) analysis. Results: Both manVMAT and autoVMAT plans were considered clinically acceptable. Target coverage was similar (manVMAT: 96.6 ± 1.6%, autoVMAT: 97.4 ± 1.0%, p = 0.085). With autoVMAT, median kidney dose was reduced on average by &gt; 25%; (for left kidney from 11.3 ± 2.1 Gy to 8.9 ± 3.5 Gy (p = 0.002); for right kidney from 9.2 ± 2.2 Gy to 6.1 ± 1.3 Gy (p &lt;  0.001)). Median dose to the liver was lower as well (18.8 ± 2.3 Gy vs. 17.1 ± 3.6 Gy, p = 0.048). In addition, Dmax of the spinal cord was significantly reduced (38.3 ± 3.7 Gy vs. 31.6 ± 2.6 Gy, p &lt;  0.001). Substantial improvements in dose conformity and integral dose were achieved with autoVMAT plans (4.2% and 9.1%, respectively; p &lt;  0.001). Due to the better OAR sparing in the autoVMAT plans compared to manVMAT plans, the predicted NTCPs for the left and right kidney and the liver-PTV were significantly reduced by 11.3%, 12.8%, 7%, respectively (p ≤ 0.001). Delivery time and total number of monitor units were increased in autoVMAT plans (from 168 ± 19 s to 207 ± 26 s, p = 0.006) and (from 781 ± 168 MU to 1001 ± 134 MU, p = 0.003), respectively. Conclusions: For postoperative/adjuvant radiotherapy of advanced gastric cancer, involving a complex target shape, automated VMAT planning is feasible and can substantially reduce the dose to the kidneys and the liver, without compromising the target dose delivery

    The impact of bone marrow sparing on organs at risk dose for cervical cancer: a Pareto front analysis

    Get PDF
    Background and purposeTo quantify the increase in bladder and rectum dose of a bone marrow sparing (BMS) VMAT strategy for primary treatment of locally advanced cervical cancer (LACC).Materials and methodsTwenty patients with stage IB-IVA cervical cancer were selected for this study. The whole Pelvic Bones (PB) was taken as substitute for bone marrow. For every patient, Pareto-optimal plans were generated to explore the trade-off between rectum, bladder, and PB mean dose. The PB mean dose was decreased in steps of 1 Gy. For each step, the increase in rectum and bladder mean dose was quantified. The increase in mean dose of other OAR compared to no BMS was constrained to 1 Gy.ResultsIn total, 931 plans of 19 evaluable patients were analyzed. The average [range] mean dose of PB without BMS was 22.8 [20.7-26.2] Gy. When maximum BMS was applied, the average reduction in mean PB dose was 5.4 [3.0-6.8] Gy resulting in an average mean PB dose of 17.5 [15.8-19.8] Gy. For &lt;1 Gy increase in both the bladder and the rectum mean dose, the PB mean dose could be decreased by &gt;2 Gy, &gt;3 Gy, &gt;4 Gy, and &gt;5 Gy for 19/19, 13/19, 5/19, and 1/19 patients, respectively.ConclusionBased on the comprehensive three-dimensional Pareto front analysis, we conclude that 2-5 Gy BMS can be implemented without a clinically relevant increase in mean dose to other OAR. If BMS is too dominant, it results in a large increase in mean dose to other OAR. Therefore, we recommend implementing moderate BMS for the treatment of LACC patients with VMAT

    Pre-clinical validation of a novel system for fully-automated treatment planning

    Get PDF
    Introduction: Many approaches for automated treatment planning (autoplanning) have been proposed and investigated. Autoplanning can enhance plan quality compared to ‘manual’ trial-and-error planning, and decrease routine planning workload. A few approaches have been implemented in commercial treatment planning systems (TPSs). We performed a pre-clinical validation of a new system (‘NovelATP’) that is based on fully-automated multi-criterial optimization (MCO). The aim of NovelATP is to automatically generate for each patient a single high-quality, Pareto-optimal plan without manual Pareto navigation. Material and methods: Validation was performed by generating VMAT/IMRT plans for conventional treatment of prostate cancer (101 pts), prostate SBRT (20 pts), bilateral head-and-neck cancer (50 pts) and rectal cancer treated at an MR-Linac (23 pts). NovelATP autoplans were compared to plans that were generated with our in-house autoplanning system. In many previous validation studies, the latter system consistently showed enhanced plan quality when compared to manual planning. Results: Dosimetrical differences between NovelATP and benchmark plans were on average small and presumably not clinically relevant, pointing at high NovelATP dosimetric plan quality. MUs were 11–19% higher with NovelATP. NovelATP delivery times were up to 12% longer. Overall, there was a slight disadvantage for NovelATP regarding gamma analyses. Calculation times for NovelATP plans were between 29 and 151 min with no overall differences with the benchmark plans. Conclusion: The new autoplanning system was able to produce high-quality plans for four highly different planning protocols/treatment sites with a total of 194 patients investigated
    corecore