    Increased Longevity of a Novel Gas Exchanger System for Low-Flow Veno-Venous Extracorporeal CO2 Removal in Acute Hypercapnic Respiratory Failure

    Full text link
    Introduction: Low-flow veno-venous extracorporeal CO2 removal (ECCO2R) is an adjunctive therapy to support lung protective ventilation or maintain spontaneous breathing in hypercapnic respiratory failure. Low-flow ECCO2R is less invasive compared to higher flow systems, while potentially compromising efficiency and membrane lifetime. To counteract this shortcoming, a high-longevity system has recently been developed. Our hypotheses were that the novel membrane system provides runtimes up to 120 h, and CO2 removal remains constant throughout membrane system lifetime. Methods: Seventy patients with pH ≤ 7.25 and/or PaCO2 ≥9 kPa exceeding lung protective ventilation limits, or experiencing respiratory exhaustion during spontaneous breathing, were treated with the high-longevity ProLUNG system or in a control group using the original gas exchanger. Treatment parameters, gas exchanger runtime, and sweep-gas VCO2 were recorded across 9,806 treatment-hours and retrospectively analyzed. Results: 25/33 and 23/37 patients were mechanically ventilated as opposed to awake spontaneously breathing in both groups. The high-longevity system increased gas exchanger runtime from 29 ± 16 to 48 ± 36 h in ventilated and from 22 ± 14 to 31 ± 31 h in awake patients (p < 0.0001), with longer runtime in the former (p < 0.01). VCO2 remained constant at 86 ± 34 mL/min (p = 0.11). Overall, PaCO2 decreased from 9.1 ± 2.0 to 7.9 ± 1.9 kPa within 1 h (p < 0.001). Tidal volume could be maintained at 5.4 ± 1.8 versus 5.7 ± 2.2 mL/kg at 120 h (p = 0.60), and peak airway pressure could be reduced from 31.1 ± 5.1 to 27.5 ± 6.8 mbar (p < 0.01). Conclusion: Using a high-longevity gas exchanger system, membrane lifetime in low-flow ECCO2R could be extended in comparison to previous systems but remained below 120 h, especially in spontaneously breathing patients. Extracorporeal VCO2 remained constant throughout gas exchanger system runtime and was consistent with removal of approximately 50% of expected CO2 production, enabling lung protective ventilation despite hypercapnic respiratory failure

    Increased Longevity of a Novel Gas Exchanger System for Low-Flow Veno-Venous Extracorporeal CO2Removal in Acute Hypercapnic Respiratory Failure

    No full text
    Introduction: Low-flow veno-venous extracorporeal CO2 removal (ECCO2R) is an adjunctive therapy to support lung protective ventilation or maintain spontaneous breathing in hypercapnic respiratory failure. Low-flow ECCO2R is less invasive compared to higher flow systems, while potentially compromising efficiency and membrane lifetime. To counteract this shortcoming, a high-longevity system has recently been developed. Our hypotheses were that the novel membrane system provides runtimes up to 120 h, and CO2 removal remains constant throughout membrane system lifetime. Methods: Seventy patients with pH ≤ 7.25 and/or PaCO2 ≥9 kPa exceeding lung protective ventilation limits, or experiencing respiratory exhaustion during spontaneous breathing, were treated with the high-longevity ProLUNG system or in a control group using the original gas exchanger. Treatment parameters, gas exchanger runtime, and sweep-gas VCO2 were recorded across 9,806 treatment-hours and retrospectively analyzed. Results: 25/33 and 23/37 patients were mechanically ventilated as opposed to awake spontaneously breathing in both groups. The high-longevity system increased gas exchanger runtime from 29 ± 16 to 48 ± 36 h in ventilated and from 22 ± 14 to 31 ± 31 h in awake patients (p < 0.0001), with longer runtime in the former (p < 0.01). VCO2 remained constant at 86 ± 34 mL/min (p = 0.11). Overall, PaCO2 decreased from 9.1 ± 2.0 to 7.9 ± 1.9 kPa within 1 h (p < 0.001). Tidal volume could be maintained at 5.4 ± 1.8 versus 5.7 ± 2.2 mL/kg at 120 h (p = 0.60), and peak airway pressure could be reduced from 31.1 ± 5.1 to 27.5 ± 6.8 mbar (p < 0.01). Conclusion: Using a high-longevity gas exchanger system, membrane lifetime in low-flow ECCO2R could be extended in comparison to previous systems but remained below 120 h, especially in spontaneously breathing patients. Extracorporeal VCO2 remained constant throughout gas exchanger system runtime and was consistent with removal of approximately 50% of expected CO2 production, enabling lung protective ventilation despite hypercapnic respiratory failure

    Severe disruption of the cytoskeleton and immunologically relevant surface molecules in a human macrophageal cell line in microgravity — Results of an in vitro experiment on board of the Shenzhou-8 space mission

    Get PDF
    During spaceflight the immune system is one of the most affected systems of the human body. During the SIMBOX (Science in Microgravity Box) mission on Shenzhou-8, we investigated microgravity-associated long-term alterations in macrophageal cells, the most important effector cells of the immune system. We analyzed the effect of long-term microgravity on the cytoskeleton and immunologically relevant surface molecules. Human U937 cells were differentiated into a macrophageal phenotype and exposed to microgravity or 1g on a reference centrifuge on-orbit for 5 days. After on-orbit fixation, the samples were analyzed with immunocytochemical staining and confocal microscopy after landing. The unmanned Shenzhou-8 spacecraft was launched on board a Long March 2F (CZ-2F) rocket from the Jiuquan Satellite Launch Center (JSLC) and landed after a 17-day-mission. We found a severely disturbed actin cytoskeleton, disorganized tubulin and distinctly reduced expression of CD18, CD36 and MHC-II after the 5 days in microgravity. The disturbed cytoskeleton, the loss of surface receptors for bacteria recognition, the activation of T lymphocytes, the loss of an important scavenger receptor and of antigen-presenting molecules could represent a dysfunctional macrophage phenotype. This phenotype in microgravity would be not capable of migrating or recognizing and attacking pathogens, and it would no longer activate the specific immune system, which could be investigated in functional assays. Obviously, the results have to be interpreted with caution as the model system has some limitations and due to numerous technical and biological restrictions (e.g. 23 °C and no CO2 supply during in-flight incubation). All parameter were carefully pre-tested on ground. Therefore, the experiment could be adapted to the experimental conditions available on Shenzhou-8
    corecore