59,708 research outputs found

    Ethical dilemmas in medical humanitarian practice: cases for reflection from Médecins Sans Frontières.

    Get PDF
    Médecins Sans Frontières (MSF) is an independent medical humanitarian organisation working in over 70 countries. It has provided medical assistance for over 35 years to populations vulnerable through conflict, disease and inadequate health systems. Medical ethics define the starting point of the relationship between medical staff and patients. The ethics of humanitarian interventions and of research in conflict settings are much debated. However, less is known about the ethical dilemmas faced by medical humanitarian staff in their daily work. Ethical dilemmas can be intensified in humanitarian contexts by insecure environments, lack of optimum care, language barriers, potentially heightened power discrepancies between care providers and patients, differing cultural values and perceptions of patients, communities and medical staff. Time constraints, stressful conditions and lack of familiarity with ethical frameworks can prevent reflection on these dilemmas, as can frustration that such reflection does not necessarily provide instant solutions. Lack of reflection, however, can be distressing for medical practitioners and can reduce the quality of care. Ethical reflection has a central role in MSF, and the organisation uses ethical frameworks to help with clinical and programmatic decisions as well as in deliberations over operational research. We illustrate and discuss some real ethical dilemmas facing MSF teams. Only by sharing and seeking guidance can MSF and similar actors make more thoughtful and appropriate decisions. Our aim in sharing these cases is to invite discussion and dialogue in the wider medical community working in crisis, conflict or with severe resource limitations

    Gas-phase and heat-exchange effects on the ignition of high- and low-exothermicity porous solids subject to constant heating

    Full text link
    This article investigates the ignition of low-exothermicity reactive porous solids exposed to a maintained source of heat (hotspot), without oxygen limitation. The gas flow within the solid, particularly in response to pressure gradients (Darcy’s law), is accounted for. Numerical experiments related to the ignition of low-exothermicity porous materials are presented. Gas and solid products of reaction are included. The first stage of the paper examines the (pseudo-homogeneous) assumption of a single temperature for both phases, amounting to an infinite rate of heat exchange between the two. Isolating the effect of gas production and flow in this manner, the effect of each on the ignition time is studied. In such cases, ignition is conveniently defined by the birth of a self-sustained combustion wave. It is found that gas production decreases the ignition time, compared to equivalent systems in which the gas-dynamic problem is effectively neglected. The reason for this is quite simple; the smaller heat capacity of the gas allows the overall temperature to attain a higher value in a similar time, and so speeds up the ignition process. Next, numerical results using a two-temperature (heterogeneous) model, allowing for local heat exchange between the phases, are presented. The pseudo-homogeneous results are recovered in the limit of infinite heat exchange. For a finite value of heat exchange, the ignition time is lower when compared to the single-temperature limit, decreasing as the rate of heat exchange decreases. However, the decrease is only mild, of the order of a few percent, indicating that the pseudo-homogeneous model is in fact a rather good approximation, at least for a constant heat-exchange rate. The relationships between the ignition time and a number of physico-chemical parameters of the system are also investigated

    Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: The case of international normalised ratio self-testing

    Get PDF
    This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. - Copyright @ 2012 Dove Medical Press LtdThis article has been made available through the Brunel Open Access Publishing Fund.Purpose: To identify factors that determine patients' intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral anticoagulation therapy with vitamin K antagonists, eg, warfarin. Methods: A cross-sectional study that applied the technology-acceptance model through a self-completed questionnaire, which was administered to a convenience sample of 125 outpatients attending outpatient anticoagulation services at a district general hospital in London, UK. Data were analyzed using descriptive statistics, factor analyses, and structural equation modeling. Results: The participants were mainly male (64%) and aged ≥ 71 years (60%). All these patients were attending the hospital outpatient anticoagulation clinic for INR testing; only two patients were currently using INR self-testing, 84% of patients had no knowledge about INR self-testing using a portable coagulometer device, and 96% of patients were never offered the option of the INR self-testing. A significant structural equation model explaining 79% of the variance in patients’ intentions to use INR self-testing was observed. The significant predictors that directly affected patients' intention to use INR self-testing were the perception of technology (β = 0.92, P < 0.001), trust in doctor (β = −0.24, P = 0.028), and affordability (β = 0.15, P = 0.016). In addition, the perception of technology was significantly affected by trust in doctor (β = 0.43, P = 0.002), age (β = −0.32, P < 0.001), and affordability (β = 0.23, P = 0.013); thereby, the intention to use INR self-testing was indirectly affected by trust in doctor (β = 0.40), age (β = −0.29), and affordability (β = 0.21) via the perception of technology. Conclusion: Patients’ intentions to use portable coagulometers for INR self-testing are affected by patients' perceptions about the INR testing device, the cost of device, trust in doctors/clinicians, and the age of the patient, which need to be considered prior to any intervention involving INR self-testing by patients. Manufacturers should focus on increasing the affordability of INR testing devices for patients’ self-testing and on the potential role of medical practitioners in supporting use of these medical devices as patients move from hospital to home testing.This study is funded by the Multidisciplinary Assessment of Technology Centre for Healthcare (MATCH) program (EPSRC grant EP/GO12393/1)

    Prediction of the capacitance lineshape in two-channel quantum dots

    Full text link
    We propose a set-up to realize two-channel Kondo physics using quantum dots. We discuss how the charge fluctuations on a small dot can be accessed by using a system of two single electron transistors arranged in parallel. We derive a microscopic Hamiltonian description of the set-up that allows us to make connection with the two-channel Anderson model (of extended use in the context of heavy-Fermion systems) and in turn make detailed predictions for the differential capacitance of the dot. We find that its lineshape, which we determined precisely, shows a robust behavior that should be experimentally verifiable.Comment: 4 pages, 3 figure

    The effect of oxygen starvation on ignition phenomena in a reactive solid containing a hot-spot

    Full text link
    In this paper, we explore the effect of oxygen supply on the conditions necessary to sustain a self-propagating front from a spherical source of heat embedded in a much larger volume of solid. The ignition characteristics for a spherical hot-spot are investigated, where the reaction is limited by oxygen, that is, reactant + oxygen ? product. It is found that over a wide range of realistic oxygen supply levels, constant heating of the solid by the hot-spot results in a self-propagating combustion front above a certain critical hot-spot power; this is clearly an important issue for industries in which hazard prevention is important. The ignition event leading to the formation of this combustion wave involves an extremely sensitive balance between the heat generated by the chemical reaction and the depletion of the reactant. As a result, for small hot-spot radii and infinite oxygen supply, not only is there a critical power above which a self-sustained combustion front is initiated there also exists a power beyond which no front is formed, before a second higher critical power is found. The plot of critical power against hot-spot radius thus takes on a Z-shape appearance. The corresponding shape for the oxygen-limited reaction is qualitatively the same when the ratio of solid thermal diffusion to oxygen mass diffusion (N) is small and we establish critical conditions for the initiation of a self-sustained combustion front in that case. As N gets larger, while still below unity, we show that the Z-shape flattens out. At still larger values of N, the supercritical behaviour becomes increasingly difficult to define and is supplanted by burning that depends more uniformly on power. In other words, the transition from slow burning to complete combustion seen at small values of N for some critical power disappears. Even higher values of N lead to less solid burning at fixed values of power

    Open-loop frequency acquisition for suppressed-carrier biphase signals using one-pole arm filters

    Get PDF
    Open loop frequency acquisition performance is discussed for suppressed carrier binary phase shift keyed signals in terms of the probability of detecting the carrier frequency offset when the arms of the Costas loop detector have one pole filters. The approach, which does not require symbol timing, uses fast Fourier transforms (FFTs) to detect the carrier frequency offset. The detection probability, which depends on both the 3 dB arm filter bandwidth and the received symbol signal to noise ratio, is derived and is shown to be independent of symbol timing. It is shown that the performance of this technique is slightly better that other open loop acquisition techniques which use integrators in the arms and whose detection performance varies with symbol timing
    corecore