    DEVELOPMENT AND VALIDATION OF REVERSED PHASE HPLC METHOD FOR ESTIMATION OF CEFTRIAXONE IN PHARMACEUTICAL DOSAGE FORM

    Get PDF
    A simple, accurate rapid and precise RP-HPLC method has been developed and validated for determination of Ceftriaxone in bulk drug. The RP-HPLC separation was achieved on Promosil C-18, (250 mm, 4.6 mm, 5µm) using mobile phase buffer: methanol ph 6.8 (90: 10 v/v) at flow rate of 1.0 ml/min at ambient temperature. The retention times were 7.111 min. for Ceftriaxone. Calibration plots were linear over the concentration range 1-20µg/ml. Quantification was achieved with photodiode array detection at 260 nm over the concentration range of 1-50 µg/ml. The method was validated statistically and applied successfully for the determination of Ceftriaxone. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for the routine determination of Ceftriaxone in bulk drug.Keywords    Ceftriaxone, Water, Buffer, Validation, HPLC

    REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE QUNTIFICATION OF CEFOTAXIME SODIUM IN PHARMACEUTICAL DOSAGE FORM

    Get PDF
    A simple, sensitive, fast & precise Reverse Phase High Performance Liquid Chromatographic method was developed for the determination of Cefotaxime Sodium in pharmaceutical dosage form. The RP-HPLC separation was achieved on hypersil C18 column (250 mm, 4.6 mm, 5µm) using mobile phase consisting of  buffer solution (sodium dihydrogen phosphate) : acetonitrile  [37: 63 v/v, pH=2.75 adjusted with phosphoric acid] at a flow rate of 1ml/min and the retention time was about 6 minutes. The method is selective to Cefotaxime Sodium and able to resolve the drug peak from formulation excipients. The system suitability with retention time was (Mean + %CV) 8.600 + 0.186.The calibration curve was linear over the concentration range of 1-20µg/ml (r2 = 0.999). The proposed method is accurate and precise (Intra day and Inter day variation, RSD were 0.55-1.67) and linear within the desired range. The LOD and LOQ was detected as 0.0187µg/ml and 0.043µg/ml respectively with r2 = 0.9997. The accuracy result of seventy percent drug (80%) was 99.87%, hundred percent (100%) was 99.93%, and one thirty percent (120%) was 100.18%. Therefore, this method could be used as a more convenient and efficient option for the analysis of Cefotaxime Sodium in raw material and Parentral dosage form.Keywords:    Third    generation    cephalosporin;    Cefotaxime Sodium;    Method    validation;    HPLC    method determination; Quantitative analysi

    ASNC/AHA/ASE/EANM/HFSA/ISA/SCMR/SNMMI expert consensus recommendations for multimodality imaging in cardiac amyloidosis: Part 2 of 2—Diagnostic criteria and appropriate utilization

    Get PDF
    Cardiac amyloidosis is emerging as an underdiagnosed cause of heart failure and mortality. Growing literature suggests that a noninvasive diagnosis of cardiac amyloidosis is now feasible. However, the diagnostic criteria and utilization of imaging in cardiac amyloidosis are not standardized. In this paper, Part 2 of a series, a panel of international experts from multiple societies define the diagnostic criteria for cardiac amyloidosis and appropriate utilization of echocardiography, cardiovascular magnetic resonance imaging, and radionuclide imaging in the evaluation of patients with known or suspected cardiac amyloidosis

    ASNC/AHA/ASE/EANM/HFSA/ISA/SCMR/SNMMI expert consensus recommendations for multimodality imaging in cardiac amyloidosis: Part 1 of 2—evidence base and standardized methods of imaging

    Get PDF
    Cardiac amyloidosis is a form of restrictive infiltrative cardiomyopathy that confers significant mortality. Due to the relative rarity of cardiac amyloidosis, clinical and diagnostic expertise in the recognition and evaluation of individuals with suspected amyloidosis is mostly limited to a few expert centers. Electrocardiography, echocardiography, and radionuclide imaging have been used for the evaluation of cardiac amyloidosis for over 40 years.1-3 Although cardiovascular magnetic resonance (CMR) has also been in clinical practice for several decades, it was not applied to cardiac amyloidosis until the late 1990s. Despite an abundance of diagnostic imaging options, cardiac amyloidosis remains largely underrecognized or delayed in diagnosis.4 While advanced imaging options for noninvasive evaluation have substantially expanded, the evidence is predominately confined to single-center small studies or limited multicenter larger experiences, and there continues to be no clear consensus on standardized imaging pathways in cardiac amyloidosis. This lack of guidance is particularly problematic given that there are numerous emerging therapeutic options for this morbid disease, increasing the importance of accurate recognition at earlier stages. Imaging provides non-invasive tools for follow-up of disease remission/progression complementing clinical evaluation. Additional areas not defined include appropriate clinical indications for imaging, optimal imaging utilization by clinical presentation, accepted imaging methods, accurate image interpretation, and comprehensive and clear reporting. Prospective randomized clinical trial data for the diagnosis of amyloidosis and for imaging-based strategies for treatment are not available. A consensus of expert opinion is greatly needed to guide the appropriate clinical utilization of imaging in cardiac amyloidosis

    ASNC/AHA/ASE/EANM/HFSA/ISA/SCMR/SNMMI Expert Consensus Recommendations for Multimodality Imaging in Cardiac Amyloidosis: Part 2 of 2—Diagnostic Criteria and Appropriate Utilization

    Get PDF
    Cardiac amyloidosis is emerging as an underdiagnosed cause of heart failure and mortality. Growing literature suggests that a noninvasive diagnosis of cardiac amyloidosis is now feasible. However, the diagnostic criteria and utilization of imaging in cardiac amyloidosis are not standardized. In this paper, Part 2 of a series, a panel of international experts from multiple societies define the diagnostic criteria for cardiac amyloidosis and appropriate utilization of echocardiography, cardiovascular magnetic resonance imaging, and radionuclide imaging in the evaluation of patients with known or suspected cardiac amyloidosis

    ASNC/AHA/ASE/EANM/HFSA/ISA/SCMR/SNMMI Expert Consensus Recommendations for Multimodality Imaging in Cardiac Amyloidosis: Part 1 of 2—Evidence Base and Standardized Methods of Imaging

    Get PDF
    Cardiac amyloidosis is a form of restrictive infiltrative cardiomyopathy that confers significant mortality. Because of the relative rarity of cardiac amyloidosis, clinical and diagnostic expertise in the recognition and evaluation of individuals with suspected amyloidosis is mostly limited to a few expert centers. Electrocardiography, echocardiography, and radionuclide imaging have been used for the evaluation of cardiac amyloidosis for over 40 years.1, 2, 3 Although cardiovascular magnetic resonance (CMR) has also been in clinical practice for several decades, it was not applied to cardiac amyloidosis until the late 1990s. Despite an abundance of diagnostic imaging options, cardiac amyloidosis remains largely underrecognized or delayed in diagnosis.4 Although advanced imaging options for noninvasive evaluation have substantially expanded, the evidence is predominately confined to single-center small studies or limited multicenter larger experiences, and there continues to be no clear consensus on standardized imaging pathways in cardiac amyloidosis. This lack of guidance is particularly problematic given that there are numerous emerging therapeutic options for this morbid disease, increasing the importance of accurate recognition at earlier stages. Imaging provides noninvasive tools for follow-up of disease remission/progression complementing clinical evaluation. Additional areas not defined include appropriate clinical indications for imaging, optimal imaging utilization by clinical presentation, accepted imaging methods, accurate image interpretation, and comprehensive and clear reporting. Prospective randomized clinical trial data for the diagnosis of amyloidosis and for imaging-based strategies for treatment are not available. A consensus of expert opinion is greatly needed to guide the appropriate clinical utilization of imaging in cardiac amyloidosis

    Predictive value of plasma galectin-3 levels in heart failure with reduced and preserved ejection fraction

    Get PDF
    Aims. Galectin-3 is an emerging biomarker which has been studied in relatively small heart failure (HF) cohorts with predominantly systolic HF. We studied the prognostic value of base-line galectin-3 in a large HF cohort, with preserved and reduced left ventricular ejection fraction (LVEF), and compared this to other biomarkers. Methods. We studied 592 HF patients who had been hospitalized for HF and were followed for 18 months. The primary end-point was a composite of all-cause mortality and HF hospitalization. Results. A doubling of galectin-3 levels was associated with a hazard ratio (HR) of 1.97 (1.62-2.42) for the primary outcome (P <0.001). After correction for age, gender, BNP, eGFR, and diabetes the HR was 1.38 (1.07-1.78; P = 0.015). Galectin-3 levels were correlated with higher IL-6 and CRP levels (P <0.002). Changes of galectin-3 levels after 6 months did not add prognostic information to the base-line value (n = 291); however, combining plasma galectin-3 and BNP levels increased prognostic value over either biomarker alone (ROC analysis, P <0.05). The predictive value of galectin-3 was stronger in patients with preserved LVEF (n = 114) compared to patients with reduced LVEF (P <0.001). Conclusions. Galectin-3 is an independent marker for outcome in HF and appears to be particularly useful in HF patients with preserved LVEF

    Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination

    Get PDF
    Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases.Nevertheless, in the published literatures,the LUS images may display a significant variation in technical execution,while scanning parameters may influence diagnostic accuracy.The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS.As expected,the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US).Consequently,having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs.The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS.Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1)select a high-end equipment with high-frequency linear array transducer (12-14 MHz).(2)Choose preset suitable for lung examination or small organs.(3)Keep the probe perpendicular to the ribs or parallel to the intercostal space.(4)Set the scanning depth at 4-5 cm.(5)Set 1-2 focal zones and adjust them close to the pleural line.(6)Use fundamental frequency with speckle reduction 2-3 or similar techniques.(7)Turn off spatial compounding imaging.(8)Adjust the time-gain compensation to get uniform image from the near-to far-field

    Agents increasing cyclic GMP amplify 5-HT4-elicited positive inotropic response in failing rat cardiac ventricle

    Get PDF
    Activation of 5-HT4 receptors in failing ventricles elicits a cAMP-dependent positive inotropic response which is mainly limited by the cGMP-inhibitable phosphodiesterase (PDE) 3. However, PDE4 plays an additional role which is demasked by PDE3 inhibition. The objective of this study was to evaluate the effect of cGMP generated by particulate and soluble guanylyl cyclase (GC) on the 5-HT4-mediated inotropic response. Extensive myocardial infarctions were induced by coronary artery ligation in Wistar rats, exhibiting heart failure 6 weeks after surgery. Contractility was measured in left ventricular preparations. Cyclic GMP was measured by EIA. In ventricular preparations, ANP or BNP displayed no impact on 5-HT4-mediated inotropic response. However, CNP increased the 5-HT4-mediated inotropic response as well as the β1-adrenoceptor (β1-AR)-mediated response to a similar extent as PDE3 inhibition by cilostamide. Pretreatment with cilostamide eliminated the effect of CNP. Inhibition of nitric oxide (NO) synthase and soluble GC by l-NAME and ODQ, respectively, attenuated the 5-HT4-mediated inotropic response, whereas the NO donor Sin-1 increased this response. The effects were absent during PDE3 inhibition, suggesting cGMP-dependent inhibition of PDE3. However, in contrast to the effects on the 5-HT4 response, Sin-1 inhibited whereas l-NAME and ODQ enhanced the β1-AR-mediated inotropic response. cGMP generated both by particulate (NPR-B) and soluble GC increases the 5-HT4-mediated inotropic response in failing hearts, probably through inhibition of PDE3. β1-AR and 5-HT4 receptor signalling are subject to opposite regulatory control by cGMP generated by soluble GC in failing hearts. Thus, cGMP from different sources is functionally compartmented, giving differential regulation of different Gs-coupled receptors
    • …