21 research outputs found
Recommended from our members
i-Tracker: For quantitative proteomics using iTRAQ (TM)
Background: iTRAQ(TM) technology for protein quantitation using mass spectrometry is a recent, powerful means of determining relative protein levels in up to four samples simultaneously. Although protein identification of samples generated using iTRAQ may be carried out using any current identification software, the quantitation calculations have been restricted to the ProQuant software supplied by Applied Biosciences. i- Tracker software has been developed to extract reporter ion peak ratios from non-centroided tandem MS peak lists in a format easily linked to the results of protein identification tools such as Mascot and Sequest. Such functionality is currently not provided by ProQuant, which is restricted to matching quantitative information to the peptide identifications from Applied Biosciences' Interrogator T software.|Results: i- Tracker is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems.|Conclusion: i- Tracker allows quantitative information gained using the iTRAQ protocol to be linked with peptide identifications from popular tandem MS identification tools and hence is both a timely and useful tool for the proteomics community
iQuantitator: A tool for protein expression inference using iTRAQ
<p>Abstract</p> <p>Background</p> <p>Isobaric Tags for Relative and Absolute Quantitation (iTRAQâ„¢) [Applied Biosystems] have seen increased application in differential protein expression analysis. To facilitate the growing need to analyze iTRAQ data, especially for cases involving multiple iTRAQ experiments, we have developed a modeling approach, statistical methods, and tools for estimating the relative changes in protein expression under various treatments and experimental conditions.</p> <p>Results</p> <p>This modeling approach provides a unified analysis of data from multiple iTRAQ experiments and links the observed quantity (reporter ion peak area) to the experiment design and the calculated quantity of interest (treatment-dependent protein and peptide fold change) through an additive model under log transformation. Others have demonstrated, through a case study, this modeling approach and noted the computational challenges of parameter inference in the unbalanced data set typical of multiple iTRAQ experiments. Here we present the development of an inference approach, based on hierarchical regression with batching of regression coefficients and Markov Chain Monte Carlo (MCMC) methods that overcomes some of these challenges. In addition to our discussion of the underlying method, we also present our implementation of the software, simulation results, experimental results, and sample output from the resulting analysis report.</p> <p>Conclusion</p> <p>iQuantitator's process-based modeling approach overcomes limitations in current methods and allows for application in a variety of experimental designs. Additionally, hypertext-linked documents produced by the tool aid in the interpretation and exploration of results.</p
Current challenges in software solutions for mass spectrometry-based quantitative proteomics
This work was in part supported by the PRIME-XS project, grant agreement number 262067, funded by the European Union seventh Framework Programme; The Netherlands Proteomics Centre, embedded in The Netherlands Genomics Initiative; The Netherlands Bioinformatics Centre; and the Centre for Biomedical Genetics (to S.C., B.B. and A.J.R.H); by NIH grants NCRR RR001614 and RR019934 (to the UCSF Mass Spectrometry Facility, director: A.L. Burlingame, P.B.); and by grants from the MRC, CR-UK, BBSRC and Barts and the London Charity (to P.C.
Recommended from our members
i-Tracker: For quantitative proteomics using iTRAQ (TM)
Background: iTRAQ(TM) technology for protein quantitation using mass spectrometry is a recent, powerful means of determining relative protein levels in up to four samples simultaneously. Although protein identification of samples generated using iTRAQ may be carried out using any current identification software, the quantitation calculations have been restricted to the ProQuant software supplied by Applied Biosciences. i- Tracker software has been developed to extract reporter ion peak ratios from non-centroided tandem MS peak lists in a format easily linked to the results of protein identification tools such as Mascot and Sequest. Such functionality is currently not provided by ProQuant, which is restricted to matching quantitative information to the peptide identifications from Applied Biosciences' Interrogator T software.|Results: i- Tracker is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems.|Conclusion: i- Tracker allows quantitative information gained using the iTRAQ protocol to be linked with peptide identifications from popular tandem MS identification tools and hence is both a timely and useful tool for the proteomics community